If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-24497 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.9,"lon":-81.32,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Beaver Township | |
Operator Name: ANTERO RESOURCES CORPORATION | |
Well Pad ID: US-OH-000817 | |
Farm/Lease Name: CARL UNIT | |
License Status: Producing | |
License Date: 2014-06-02 | |
Spud Date: 2014-06-03 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2014-11-29 | |
Well Total Depth: 16120.00 ft | |
Configuration: Horizontal | |
Latitude: 39.900000 | |
Longitude: -81.320000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-06-02 | Proposed Formations:POINT PLEASANT, Issued Date:6/2/2014, Expired Date:6/1/2016 12:00:00 PM, Drilling unit acres:454.155, Proposed Well Type:OG, Proposed Well Class:EOUT |
Reached Total Depth | 2014-11-29 | |
Correction to Well | 2015-01-30 | UPDATE TO UNIT SIZE. CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
Completion Report Received | 2015-08-20 | |
Construction Permit Expires | 2016-06-01 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 04/28/2015 | 05/09/2015 | 7769 | 11,344,300.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WFR-6W | C&J Well Services | Friction Reducer | Anionic Water-Soluble Polymer Emulsion | Proprietary | 100 | 0.063938 | 0 |
LSG-100L | C&J Well Services | Gelling Agents | Petroleum Distillates | 64742-47-8 | 70 | 0.038454 | 0 | |
Acid Inhibitor 2 (AI-2) | C&J Well Services | Acid Corrosion Inhibitors | 2-Butoxyethanol | 111-76-2 | 20 | 0.000141 | 0 | |
Isopropyl Alcohol | 67-63-0 | 20 | 0.000141 | 0 | ||||
Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00007000 | 0 | ||||
Proprietary | Proprietary | 15 | 0.000105 | 0 | ||||
Propargyl Alcohol | 107-19-7 | 20 | 0.000141 | 0 | ||||
AQUCAR DB 20 | C&J Well Services | Biocides | Dibromoacetonitrile | 3252-43-5 | 3 | 0.000414 | 0 | |
Polyethylene glycol | 25322-68-3 | 54.5 | 0.007519 | 0 | ||||
Sodium bromide | 7647-15-6 | 4 | 0.000552 | 0 | ||||
2,2-Dibromo-3-nitrilo-propionamide (DBNPA) | 10222-01-2 | 20 | 0.002759 | 0 | ||||
Super TSC 2 LT | C&J Well Services | Paraffin & Scale Additives | Bis(hexamethylene triaminepenta
(methylenephosphonic acid)) |
Proprietary | 10 | 0.001672 | 0 | |
Water | ANTERO RESOURCES | Water | Water | 7732-18-5 | 100 | 89.4463 | 0 | |
Other Ingredients | C&J Well Services | Other Ingredients | Water | 7732-18-5 | 40 | 0.025575 | 0 | |
Proprietary | Proprietary | 0.99 | 0.00000700 | 0 | ||||
2-Propenamide as residual | 79-06-1 | 0.1 | 0.00006400 | 0 | ||||
guar gum | 9000-30-0 | 50 | 0.027467 | 0 | ||||
Glycol Ethers | 111-46-6 | 40 | 0.000281 | 0 | ||||
Ethoxylated alcohols | Proprietary | 4 | 0.002558 | 0 | ||||
Water | 7732-18-5 | 100 | 0.000212 | 0 | ||||
Copolymer | Proprietary | 100 | 0.063938 | 0 | ||||
Sodium Hydroxide | 1310-73-2 | 1 | 0.000167 | 0 | ||||
Monobromo-3-nitrilopropionamide | 1113-55-9 | 1 | 0.000138 | 0 | ||||
Proprietary | Proprietary | 0.02 | 0 | 0 | ||||
Proprietary | Proprietary | 1 | 0.00000400 | 0 | ||||
Crystalline Silica (in the form of quartz) | 14808-60-7 | 2 | 0.001099 | 0 | ||||
Isoparaffinic Solvent | 64742-47-8 | 26 | 0.016624 | 0 | ||||
Organophylic Clay | 68953-58-2 | 0 | 0 | 0 | ||||
Sugar | 57-50-1 | 100 | 0.000423 | 0 | ||||
Ethylene Glycol | 107-21-1 | 4 | 0.002558 | 0 | ||||
Water | 7732-18-5 | 48 | 0.000337 | 0 | ||||
Water | 7732-18-5 | 32 | 0.004415 | 0 | ||||
Surfactant | 68439-51-0 | 2 | 0.001099 | 0 | ||||
Proprietary | Proprietary | 100 | 0.000423 | 0 | ||||
Cured Acrylic Resin | Proprietary | 22 | 0.000216 | 0 | ||||
2,2-Dibromomalonamide | 73003-80-2 | 1 | 0.000138 | 0 | ||||
Water | 7732-18-5 | 90 | 0.015052 | 0 | ||||
Surfactant Blend | Proprietary | 3 | 0.001918 | 0 | ||||
EB-4L | C&J Well Services | Gel Breakers | Ethylene Glycol | 107-21-1 | 40 | 0.000169 | 0 | |
OB-2 LT | C&J Well Services | Gel Breakers | Talc | 14807-96-6 | 1 | 0.00001000 | 0 | |
Ammonium Persulfate | 7727-54-0 | 85 | 0.000836 | 0 | ||||
Super GREEN SOLV-M | C&J Well Services | Paraffin & Scale Additives | Aliphatic Hydrocarbons | Proprietary | 95 | 0.000462 | 0 | |
Dodecane | Proprietary | 14 | 0.00006800 | 0 | ||||
Tridecane | Proprietary | 9 | 0.00004400 | 0 | ||||
tetradecane | Proprietary | 11 | 0.00005300 | 0 | ||||
Undecane | Proprietary | 8 | 0.00003900 | 0 | ||||
HCl Acid (12.5-18.0%), 22 Baume | C&J Well Services | Bulk Acid | Hydrochloric Acid | 7647-01-0 | 18 | 0.067059 | 0 | |
Water | 7732-18-5 | 87.5 | 0.325982 | 0 | ||||
Sand | C&J Well Services | Sand - Bulk - West Virginia | Titanium Oxide | 13463-67-7 | 0.1 | 0.004105 | 0 | |
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 4.52415 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.045156 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.004529 | 0 | ||||
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 1.39393 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.001395 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.001395 | 0 | ||||
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 4.10103 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.049815 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.004105 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.015349 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.004529 | 0 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ANTERO RESOURCES CORPORATION | 1017143 | 45160 | 184 |
2016 | ANTERO RESOURCES CORPORATION | 899667 | 9047 | 359 |
2017 | ANTERO RESOURCES CORPORATION | 439333 | 3190 | 365 |
2018 | ANTERO RESOURCES CORPORATION | 238060 | 1322 | 342 |
2019 | ANTERO RESOURCES CORPORATION | 66584 | 389 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ANTERO RESOURCES CORPORATION | Brine | 13504 | 184 |
2016 | ANTERO RESOURCES CORPORATION | Brine | 6858 | 359 |
2017 | ANTERO RESOURCES CORPORATION | Brine | 3288 | 365 |
2018 | ANTERO RESOURCES CORPORATION | Brine | 1916 | 342 |
2019 | ANTERO RESOURCES CORPORATION | Brine | 532 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1419692932 | 2014-11-17 0:00 | DD | No Violations | 1.00 |
-1813566774 | 2019-12-5 0:00: | PW | No Violations | 0.50 |
-1932395252 | 2017-1-25 0:00: | PW | No Violations | 0.10 |
-65430217 | 2014-6-13 0:00: | CS | No Violations | 3.00 |
-699812004 | 2015-8-3 0:00:0 | PL | No Violations | 0.50 |
-736721283 | 2016-1-13 0:00: | PW | No Violations | 0.30 |
-980603213 | 2017-8-7 0:00:0 | PW | No Violations | 0.20 |
0065430217 | 2014-06-13 | Casing String Witnessed | No Violations | I am onsite to witness the surface casing cementing operations. Falcon rig 27 drilled 380 of 24 hole and ran 367 of 18.625 inch 87.5 pound casing. Allied Oil and Gas Services circulated 757 sacks of class A cement into place. The cement mix water tested at 101 ppm chlorides on a low range Quantab. |
0699812004 | 2015-08-03 | Preliminary Restoration | No Violations | My inspection today finds the well site meets the preliminary restoration requirements of 1509.072(A). The well is produced into a tank battery comprised of fourteen 400 barrel tanks set inside of a plastic lined steel containment. |
0736721283 | 2016-01-13 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery is comprised of fourteen 400 barrel tanks set inside of a plastic lined, liquid tight steel containment system. There are four incinerators set at the location. Seven other wells are located on the pad and share the production equipment. The ground is covered by three inches of snow at the time of inspection. |
0980603213 | 2017-08-07 | Production Wells | No Violations | The purpose of my inspection today was a status check on a production well. The pad was named Ervin and it consisted of 8 wells. During my inspection the well was equipped with a production tree style wellhead with production valves in the open position. The production casing had a gauge present reading 243 pounds per square inch and the production tubing had a gauge present reading 168 pounds per square inch. The production equipment consisted of fourteen 400 barrel tanks, 8 gas production units, 4 compressors, and 2 combustors. The natural gas pipeline tie in was located on the south side of the pad. The identification was located on the well and the 400 barrel tank. |
1095806256 | 2015-07-10 | Production Wells | No Violations | Status check inspection as a follow up to a on site accident that occurred on 07-08-2015. Upon inspection on this day I met with Anteros HSE representative Chris Warnock and Myers Well Service Regional Safety officer John Moore who indicated the employee of Myers Well Service was injured when a 3 line used in the production fluid transfer process was attempted to be disconnected from the water truck while under pressure causing the line to release from its connection and struck the employee in the face causing lacerations and fractures to the face. The line was free from fluid and no well bore related product was released. The company(Antero) has implemented a safety stand down until the incident can be investigated and corrections can be made to further avoid any future incidents. Addressing the well location a total of 8 wells were found on site and in production with a total of 14 production tanks present with a total capacity of 400 barrels each. All tanks were found inside of a poly lined metal construction containment dike area. Also on site there is a total of 8 gas processing units one supporting each existing well on the location. With proper well identification posted at the well head. Myers Well Service Ohio UIC # 25-427 water trucks were on location along with Ohio Oil Gathering hauling production fluid from the site. |
1402937165 | 2014-06-16 | Casing String Witnessed | No Violations | My inspection today finds Falcon rig 27 drilled a 17.5 hole to a depth of 1905. The rig crew ran 1870 of 13.625 casing. Allied cemented the casing in place with 1427 sacks of class A cement. I witnessed 22 barrels of cement to surface. |
1419692932 | 2014-11-17 | Drill / Deepen / Reopen | No Violations | My inspection today finds the drilling rig, Patterson 340, is building the bottom hole assembly to begin drilling the 8.75 curve and lateral. |
1932395252 | 2017-01-25 | Production Wells | No Violations | The purpose of my inspection is a status check on a producing well. The pad name is Ervin Pad and there are a total of 8 wells on this pad. During my inspection the well was equipped with a production tree style wellhead. The production equipment for this well consists of 14 400 barrel tanks within containment, and eight gas processing units. The vapor recovery system consists of two compressors and four Cimarron combustors. The production records are current, the identification is located at the wellhead, and there are no violations present. |
2055553061 | 2015-06-03 | Completion Testing | No Violations | My inspection today finds the service contractor, Fortis, has drilled out 32 completion plugs and are currently drilling plug number 33. Fire extinguishers are located around location as required. |
For data sources see[8]