Well Details

Well ID: 34-121-24516
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Seneca Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-000784
Farm/Lease Name: SENECA UNIT
License Status: Producing
License Date: 2014-10-06
Spud Date: 2014-07-20
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2014-10-25
Well Total Depth: 18984.00 ft
Configuration: Horizontal
Latitude: 39.880000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-07-01 Proposed Formations:POINT PLEASANT, Issued Date:7/1/2014, Expired Date:6/30/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2014-10-06 Proposed Formations:POINT PLEASANT, Issued Date:10/6/2014, Expired Date:10/5/2016 12:00:00 PM, Drilling unit acres:913.1626, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2014-10-25
Completion Report Received 2016-02-22
Construction Permit Expires 2016-10-05
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2015-06-02 8250 18681 0
8250 18681 0
8250 18681 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 02/08/2015 03/04/2015 7722 16,704,700.0 736092

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AP One U.S. Well Services Gel Breakers Ammonium Persulfate 7727-54-0 100 0.00139 2148
LGC-15 U.S. Well Services Gelling Agents Surfactant 68439-51-0 3 0.00195 3002.99
Petroleum Distillates 64742-47-8 60 0.03077 47400.1
Guar Gum 9000-30-0 50 0.03249 50049.8
Suspending agent (solid) 14808-60-7 3 0.00497 7654.67
K-BAC 1020 U.S. Well Services Anti-Bacterial Agent Deionized Water 7732-18-5 28 0.00252 3878.77
2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00441 6790.61
AI-301 U.S. Well Services Acid Corrosion Inhibitors Diethylene Glycol 111-46-6 30 0.00021 327.569
Methenamine 100-97-0 20 0.00017 259.557
Hydrogen Chloride 7647-01-0 10 0.00007000 113.19
Coco amine 61791-14-8 5 0.00003000 44.8859
Polyethylene polyamine 68603-67-8 10 0.00006000 98.261
WFRA-405 U.S. Well Services Friction Reducer Anionic Polyacrylamide Proprietary 40 0.0208 32052.3
Ethoxylated alcohol blend Proprietary 5 0.0026 4006.54
Water 7732-18-5 40 0.0208 32052.3
Sodium Chloride 7647-14-5 20 0.0104 16026.1
Petroleum Distillates 64742-47-8 20 0.00837 12901
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 9.06182 13,960,700.0
SI-1100 U.S. Well Services Scale Inhibitor Potassium salt of diethylene triamine

penta (methylene phosphonic acid)

15827-60-8 10 0.00173 2661.63
Copolymer of Maleic and Acrylic acid 26677-99-6 10 0.00151 2326.46
2-Phosphonobutane 1,2,4 tricarboxylic salt 37971-36-1 10 0.00165 2543.33
hexamethylenediamine tetra (methylene phosphonic acid) 38820-59-6 10 0.0016 2464.47
Ethylene Glycol 107-21-1 40 0.00578 8911.52
bis (hexamethylene) tramine penta

(methylene phosphonic acid) - phosphate acid

40623-75-4 10 0.00147 2267.31
Acrylic polymer 52255-49-9 5 0.00064 985.788
Di Water 7732-18-5 80 0.01024 15772.6
HCL Acid (12.6%-18.0%) U.S. Well Services, LLC Bulk Acid Hydrogen Chloride 7647-01-0 18 0.06584 101436
Water 7732-18-5 87.5 0.27564 424654
Water Antero Resources Base Fluid Water 7732-18-5 100 90.43 139,318,000.0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2015-02-11 H2O 0 6689 Bbl 244510 US Well Services Inc I witnessed zero annular pressure. Additives are listed on the job summary.
2015-03-04 H2O 15 5858 Bbl 245800 US Well Services Inc I witnessed no annular pressure.
2015-03-04 H2O 0 5864 Bbl 246450 US Well Services Inc I witnessed no annular pressure.
2015-03-03 H2O 0 5879 Bbl 248050 US Well Services Inc I witnessed no annular pressure.
2015-02-24 H2O 0 6148 Bbl 239840 US Well Services Inc No annular pressure witnessed during the job.
2015-02-09 H2O 0 6636 Bbl 165350 US Well Services Inc Zero annular pressure witnessed.
2015-02-26 H2O 0 6464 Bbl 246640 US Well Services Inc A valve failed during the pressure test and had to be repaired before the stage could begin.

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2015 ANTERO RESOURCES CORPORATION 1054512 88484 233
2016 ANTERO RESOURCES CORPORATION 721482 44639 359
2017 ANTERO RESOURCES CORPORATION 441110 24449 364
2018 ANTERO RESOURCES CORPORATION 205295 11091 344
2019 ANTERO RESOURCES CORPORATION 59499 3038 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2015 ANTERO RESOURCES CORPORATION Brine 22165 233
2016 ANTERO RESOURCES CORPORATION Brine 6749 359
2017 ANTERO RESOURCES CORPORATION Brine 3645 364
2018 ANTERO RESOURCES CORPORATION Brine 2560 344
2019 ANTERO RESOURCES CORPORATION Brine 654 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1627497818 2016-7-28 0:00: PW No Violations 0.50
-1841464684 2016-1-13 0:00: PW No Violations 0.30
-1993401106 2015-2-4 0:00:0 DD No Violations 1.00
-730906736 2014-7-23 0:00: CS No Violations 4.50
-762369109 2014-7-29 0:00: DD No Violations 1.00
-868598075 2015-7-29 0:00: PW No Violations
-90035633 2017-10-18 0:00 PW No Violations 0.50
-925246993 2020-3-18 0:00: PL No Violations 0.30
-926806870 2017-3-15 0:00: PW No Violations 0.50
-951364542 2015-6-16 0:00: PW No Violations 0.20
0090035633 2017-10-18 Production Wells No Violations The purpose of my inspection was a status check on a production well. The well pad name is Cynthia and it consists of 5 wells. The well was equipped with a production tree style wellhead. Production valves were in the open position. Annular pressure monitoring was present. The gauge on the production casing read 280 pounds per square inch and the gauge on the production tubing read 170 pounds per square inch. The production equipment consisted of eight 400 barrel tanks within steel line containment and five gas production units. A vapor recovery system consisted of two compressors, one vent scrubber, and three combustors. The pipeline tie in was located on the North side of the pad. A dust suppressant had been recently applied to the lease road. The identification was located at the wellhead and the production records were current.
0256133134 2015-02-26 Drill / Deepen / Reopen No Violations I am onsite to witness stage 39 of the hydraulic stimulation operations. No annular pressure was noted during the inspection. All volumes and pressures are recorded in the Stimulation Report.
0713837600 2016-02-25 Production Wells No Violations My inspection today finds the well is equipped in a manner that is consistent with being capable of production. The tank battery is comprised of eight 400 barrel tanks set inside of a plastic lined steel containment system. There are no personnel onsite at the time of inspection. The rainwater drainage sumps are open at the time of inspection.
0730906736 2014-07-23 Casing String Witnessed No Violations I am onsite to witness the conductor cementing operations. Express Energy Services drilled to a depth of 80. Express cemented the casing in place with 260 sacks of class A cement. I witnessed 15 barrels of cement return to surface.
0762369109 2014-07-29 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig, Falcon Drilling rig 27, is drilling 17.5 hole at a depth of 2034. The anticipated total depth is 2044.
0868598075 2015-07-29 Production Wells No Violations My inspection today finds the well properly equipped to be capable of production. While on location I witnessed one Myers truck arrive, load brine and depart. The water sumps and drainage system on the perimeter of the location has been recently cleaned and repaired.
0917821703 2014-10-20 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig is drilling 8.75 hole a measured depth of 18,653. The planned total depth is 18,984.
0926806870 2017-03-15 Production Wells No Violations The pad name is Cynthia and it consists of 5 wells. The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Annular pressure monitoring was present. The production equipment consisted of five gas production units, eight 400 barrel tanks, two compressors, and three combustors. Identification was present and production records were current.
0951364542 2015-06-16 Production Wells No Violations The well is equipped in a manner consistent with being capable of production. All drainage sumps on the location are closed.
0979535191 2017-12-01 Production Wells No Violations
1049821510 2019-12-5 0:00: PW No Violations 0.50
1118783967 2015-02-24 Drill / Deepen / Reopen No Violations I am onsite to witness the hydraulic stimulation operations on stage 32. I monitored the annular pressure through out the job and witnessed no annular pressures. All job pressures and rates will be noted in the stimulation report.
1190982312 2015-03-03 Drill / Deepen / Reopen No Violations I am onsite to monitor the hydraulic stimulation operations of stage 56. I witnessed zero annular pressure though out the job. All volumes and rates will be documented in the stimulation report.
1443527482 2015-09-29 Preliminary Restoration No Violations My inspection today finds the well site meets the preliminary restoration requirements of 1509:072(A).
1627497818 2016-07-28 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery consists of eight 400 barrel tanks set in a plastic lined liquid tight steel containment. The tank battery is shared by four other wells on the pad. Two vapor recovery compressors and three incinerators are located near the entry of the well pad. Heavy rain is falling at the time of inspection.
1692609820 2018-11-27 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.875-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 300 pounds per square inch, the 9.625-inch diameter casing had 0 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 8- 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was secondary containment around the production fluid tanks, and the Gas Processing Units. There was a midstream valve site on the northwest side of the pad. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date.
1841464684 2016-01-13 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery is comprised of eight 400 barrel tanks set inside of a plastic lined, liquid tight steel containment system. There are three vapor recovery units and three incinerators set at the location. Four other wells are located on the pad and share the production equipment. The ground is covered by three inches of snow at the time of inspection.
1993401106 2015-02-04 Drill / Deepen / Reopen No Violations After reviewing the cement bond log that was performed by Renegade Services on 12-30-2014 and conferring with manager Brent Bear the decision was made to require 1000 of separation between the cement top at 7241 and the upper most perforation. At 1:40 PM, I called Steve Self, Completions Manager for Antero Resources, and discussed the 1000 requirement. Mr. Self agreed to the condition that well not be perforated above 8241.
256133134 2015-2-26 0:00: DD No Violations 3.00
713837600 2016-2-25 0:00: PW No Violations
917821703 2014-10-20 0:00 DD No Violations 1.50
979535191 2017-12-1 0:00: PW No Violations 0.50

For data sources see[10]