{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.88,"lon":-81.4,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Seneca Township | |
Operator Name: ANTERO RESOURCES CORPORATION | |
Well Pad ID: US-OH-000784 | |
Farm/Lease Name: SENECA UNIT | |
License Status: Producing | |
License Date: 2014-10-06 | |
Spud Date: 2014-07-20 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2014-10-25 | |
Well Total Depth: 18984.00 ft | |
Configuration: Horizontal | |
Latitude: 39.880000 | |
Longitude: -81.400000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-07-01 | Proposed Formations:POINT PLEASANT, Issued Date:7/1/2014, Expired Date:6/30/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2014-10-06 | Proposed Formations:POINT PLEASANT, Issued Date:10/6/2014, Expired Date:10/5/2016 12:00:00 PM, Drilling unit acres:913.1626, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2014-10-25 | |
Completion Report Received | 2016-02-22 | |
Construction Permit Expires | 2016-10-05 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2015-06-02 | 8250 | 18681 | 0 |
8250 | 18681 | 0 | |
8250 | 18681 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 02/08/2015 | 03/04/2015 | 7722 | 16,704,700.0 | 736092 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | AP One | U.S. Well Services | Gel Breakers | Ammonium Persulfate | 7727-54-0 | 100 | 0.00139 | 2148 |
LGC-15 | U.S. Well Services | Gelling Agents | Surfactant | 68439-51-0 | 3 | 0.00195 | 3002.99 | |
Petroleum Distillates | 64742-47-8 | 60 | 0.03077 | 47400.1 | ||||
Guar Gum | 9000-30-0 | 50 | 0.03249 | 50049.8 | ||||
Suspending agent (solid) | 14808-60-7 | 3 | 0.00497 | 7654.67 | ||||
K-BAC 1020 | U.S. Well Services | Anti-Bacterial Agent | Deionized Water | 7732-18-5 | 28 | 0.00252 | 3878.77 | |
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.00441 | 6790.61 | ||||
AI-301 | U.S. Well Services | Acid Corrosion Inhibitors | Diethylene Glycol | 111-46-6 | 30 | 0.00021 | 327.569 | |
Methenamine | 100-97-0 | 20 | 0.00017 | 259.557 | ||||
Hydrogen Chloride | 7647-01-0 | 10 | 0.00007000 | 113.19 | ||||
Coco amine | 61791-14-8 | 5 | 0.00003000 | 44.8859 | ||||
Polyethylene polyamine | 68603-67-8 | 10 | 0.00006000 | 98.261 | ||||
WFRA-405 | U.S. Well Services | Friction Reducer | Anionic Polyacrylamide | Proprietary | 40 | 0.0208 | 32052.3 | |
Ethoxylated alcohol blend | Proprietary | 5 | 0.0026 | 4006.54 | ||||
Water | 7732-18-5 | 40 | 0.0208 | 32052.3 | ||||
Sodium Chloride | 7647-14-5 | 20 | 0.0104 | 16026.1 | ||||
Petroleum Distillates | 64742-47-8 | 20 | 0.00837 | 12901 | ||||
Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 9.06182 | 13,960,700.0 | |
SI-1100 | U.S. Well Services | Scale Inhibitor | Potassium salt of diethylene triamine
penta (methylene phosphonic acid) |
15827-60-8 | 10 | 0.00173 | 2661.63 | |
Copolymer of Maleic and Acrylic acid | 26677-99-6 | 10 | 0.00151 | 2326.46 | ||||
2-Phosphonobutane 1,2,4 tricarboxylic salt | 37971-36-1 | 10 | 0.00165 | 2543.33 | ||||
hexamethylenediamine tetra (methylene phosphonic acid) | 38820-59-6 | 10 | 0.0016 | 2464.47 | ||||
Ethylene Glycol | 107-21-1 | 40 | 0.00578 | 8911.52 | ||||
bis (hexamethylene) tramine penta
(methylene phosphonic acid) - phosphate acid |
40623-75-4 | 10 | 0.00147 | 2267.31 | ||||
Acrylic polymer | 52255-49-9 | 5 | 0.00064 | 985.788 | ||||
Di Water | 7732-18-5 | 80 | 0.01024 | 15772.6 | ||||
HCL Acid (12.6%-18.0%) | U.S. Well Services, LLC | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 18 | 0.06584 | 101436 | |
Water | 7732-18-5 | 87.5 | 0.27564 | 424654 | ||||
Water | Antero Resources | Base Fluid | Water | 7732-18-5 | 100 | 90.43 | 139,318,000.0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2015-02-11 | H2O | 0 | 6689 Bbl | 244510 | US Well Services Inc | I witnessed zero annular pressure. Additives are listed on the job summary. |
2015-03-04 | H2O | 15 | 5858 Bbl | 245800 | US Well Services Inc | I witnessed no annular pressure. |
2015-03-04 | H2O | 0 | 5864 Bbl | 246450 | US Well Services Inc | I witnessed no annular pressure. |
2015-03-03 | H2O | 0 | 5879 Bbl | 248050 | US Well Services Inc | I witnessed no annular pressure. |
2015-02-24 | H2O | 0 | 6148 Bbl | 239840 | US Well Services Inc | No annular pressure witnessed during the job. |
2015-02-09 | H2O | 0 | 6636 Bbl | 165350 | US Well Services Inc | Zero annular pressure witnessed. |
2015-02-26 | H2O | 0 | 6464 Bbl | 246640 | US Well Services Inc | A valve failed during the pressure test and had to be repaired before the stage could begin. |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ANTERO RESOURCES CORPORATION | 1054512 | 88484 | 233 |
2016 | ANTERO RESOURCES CORPORATION | 721482 | 44639 | 359 |
2017 | ANTERO RESOURCES CORPORATION | 441110 | 24449 | 364 |
2018 | ANTERO RESOURCES CORPORATION | 205295 | 11091 | 344 |
2019 | ANTERO RESOURCES CORPORATION | 59499 | 3038 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ANTERO RESOURCES CORPORATION | Brine | 22165 | 233 |
2016 | ANTERO RESOURCES CORPORATION | Brine | 6749 | 359 |
2017 | ANTERO RESOURCES CORPORATION | Brine | 3645 | 364 |
2018 | ANTERO RESOURCES CORPORATION | Brine | 2560 | 344 |
2019 | ANTERO RESOURCES CORPORATION | Brine | 654 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1627497818 | 2016-7-28 0:00: | PW | No Violations | 0.50 |
-1841464684 | 2016-1-13 0:00: | PW | No Violations | 0.30 |
-1993401106 | 2015-2-4 0:00:0 | DD | No Violations | 1.00 |
-730906736 | 2014-7-23 0:00: | CS | No Violations | 4.50 |
-762369109 | 2014-7-29 0:00: | DD | No Violations | 1.00 |
-868598075 | 2015-7-29 0:00: | PW | No Violations | |
-90035633 | 2017-10-18 0:00 | PW | No Violations | 0.50 |
-925246993 | 2020-3-18 0:00: | PL | No Violations | 0.30 |
-926806870 | 2017-3-15 0:00: | PW | No Violations | 0.50 |
-951364542 | 2015-6-16 0:00: | PW | No Violations | 0.20 |
0090035633 | 2017-10-18 | Production Wells | No Violations | The purpose of my inspection was a status check on a production well. The well pad name is Cynthia and it consists of 5 wells. The well was equipped with a production tree style wellhead. Production valves were in the open position. Annular pressure monitoring was present. The gauge on the production casing read 280 pounds per square inch and the gauge on the production tubing read 170 pounds per square inch. The production equipment consisted of eight 400 barrel tanks within steel line containment and five gas production units. A vapor recovery system consisted of two compressors, one vent scrubber, and three combustors. The pipeline tie in was located on the North side of the pad. A dust suppressant had been recently applied to the lease road. The identification was located at the wellhead and the production records were current. |
0256133134 | 2015-02-26 | Drill / Deepen / Reopen | No Violations | I am onsite to witness stage 39 of the hydraulic stimulation operations. No annular pressure was noted during the inspection. All volumes and pressures are recorded in the Stimulation Report. |
0713837600 | 2016-02-25 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner that is consistent with being capable of production. The tank battery is comprised of eight 400 barrel tanks set inside of a plastic lined steel containment system. There are no personnel onsite at the time of inspection. The rainwater drainage sumps are open at the time of inspection. |
0730906736 | 2014-07-23 | Casing String Witnessed | No Violations | I am onsite to witness the conductor cementing operations. Express Energy Services drilled to a depth of 80. Express cemented the casing in place with 260 sacks of class A cement. I witnessed 15 barrels of cement return to surface. |
0762369109 | 2014-07-29 | Drill / Deepen / Reopen | No Violations | My inspection today finds the drilling rig, Falcon Drilling rig 27, is drilling 17.5 hole at a depth of 2034. The anticipated total depth is 2044. |
0868598075 | 2015-07-29 | Production Wells | No Violations | My inspection today finds the well properly equipped to be capable of production. While on location I witnessed one Myers truck arrive, load brine and depart. The water sumps and drainage system on the perimeter of the location has been recently cleaned and repaired. |
0917821703 | 2014-10-20 | Drill / Deepen / Reopen | No Violations | My inspection today finds the drilling rig is drilling 8.75 hole a measured depth of 18,653. The planned total depth is 18,984. |
0926806870 | 2017-03-15 | Production Wells | No Violations | The pad name is Cynthia and it consists of 5 wells. The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Annular pressure monitoring was present. The production equipment consisted of five gas production units, eight 400 barrel tanks, two compressors, and three combustors. Identification was present and production records were current. |
0951364542 | 2015-06-16 | Production Wells | No Violations | The well is equipped in a manner consistent with being capable of production. All drainage sumps on the location are closed. |
0979535191 | 2017-12-01 | Production Wells | No Violations | |
1049821510 | 2019-12-5 0:00: | PW | No Violations | 0.50 |
1118783967 | 2015-02-24 | Drill / Deepen / Reopen | No Violations | I am onsite to witness the hydraulic stimulation operations on stage 32. I monitored the annular pressure through out the job and witnessed no annular pressures. All job pressures and rates will be noted in the stimulation report. |
1190982312 | 2015-03-03 | Drill / Deepen / Reopen | No Violations | I am onsite to monitor the hydraulic stimulation operations of stage 56. I witnessed zero annular pressure though out the job. All volumes and rates will be documented in the stimulation report. |
1443527482 | 2015-09-29 | Preliminary Restoration | No Violations | My inspection today finds the well site meets the preliminary restoration requirements of 1509:072(A). |
1627497818 | 2016-07-28 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery consists of eight 400 barrel tanks set in a plastic lined liquid tight steel containment. The tank battery is shared by four other wells on the pad. Two vapor recovery compressors and three incinerators are located near the entry of the well pad. Heavy rain is falling at the time of inspection. |
1692609820 | 2018-11-27 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.875-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 300 pounds per square inch, the 9.625-inch diameter casing had 0 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 8- 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was secondary containment around the production fluid tanks, and the Gas Processing Units. There was a midstream valve site on the northwest side of the pad. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date. |
1841464684 | 2016-01-13 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery is comprised of eight 400 barrel tanks set inside of a plastic lined, liquid tight steel containment system. There are three vapor recovery units and three incinerators set at the location. Four other wells are located on the pad and share the production equipment. The ground is covered by three inches of snow at the time of inspection. |
1993401106 | 2015-02-04 | Drill / Deepen / Reopen | No Violations | After reviewing the cement bond log that was performed by Renegade Services on 12-30-2014 and conferring with manager Brent Bear the decision was made to require 1000 of separation between the cement top at 7241 and the upper most perforation. At 1:40 PM, I called Steve Self, Completions Manager for Antero Resources, and discussed the 1000 requirement. Mr. Self agreed to the condition that well not be perforated above 8241. |
256133134 | 2015-2-26 0:00: | DD | No Violations | 3.00 |
713837600 | 2016-2-25 0:00: | PW | No Violations | |
917821703 | 2014-10-20 0:00 | DD | No Violations | 1.50 |
979535191 | 2017-12-1 0:00: | PW | No Violations | 0.50 |
For data sources see[10]