34-123-20054

Well Details

Well ID: 34-123-20054
Loading map...
Country: United States
State: Ohio
County: Ottawa
Municipality: Carroll Township
Operator Name: HEMMINGER CARL & ALICE
Well Pad ID:
Farm/Lease Name: HEMMINGER
License Status: Final Restoration
License Date: 2017-06-29
Spud Date: 1980-06-22
Spud Drilling Contractor:
Final Drill Date: 1980-07-17
Well Total Depth: 1470.00 ft
Configuration: Vertical
Latitude: 41.580000
Longitude: -83.140000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1980-06-22 GL=575.9
Completed 1980-07-17 GL=575.9
Reached Total Depth 1980-07-17 GL=575.9
CO 1980-07-28 2976 HEMMINGER CARL & ALICE GeoDate 7/28/80
APP 2017-06-29 Proposed Formations:TRENTON, Issued Date:6/29/2017, Expired Date:6/29/2019 12:00:00 PM, Drilling unit acres:39.65, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-10-03 GL=575.9
Record Last Modified 2018-04-16 GL=575.9
Construction Permit Expires 2019-06-29 GL=575.9

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1807277127 2017-10-3 0:00: PB No Violations
0283237147 2017-03-17 Production Wells No Violations Identification is posted at well. This well currently has a high pressure gas regulator installed at well. Well is currently shut in and owner is in the process of obtaining quotes on possibly plugging well.
1435975640 2017-12-08 Plug / Plug Back No Violations Jet Wireline was on site to determine the depth of the packer that is on the 1.5 inch tubing and to shoot off and free the 1.5 inch tubing. The packer was determined to be at 1440 feet below grade. The first attempt to shoot the tubing at 1415 feet was a dead shot. The shot failed, the operator had to trip out of the hole to evaluate the wiring.
1499367106 2017-07-06 Production Wells No Violations Received plug permit from Central Office recently. Inspected well area for violations. Identification is posted at well and also answered questions about plugging requirements to potential plugging contractor.
1505847924 2017-09-19 Plug / Plug Back No Violations Witnessed the installation of 100 Sacks of Class A Cement through tubing to install an approximate 500 foot bottom plug on well.
1507130776 2017-10-02 Plug / Plug Back No Violations Top of first plug was measured to a depth of 785 feet. Installed 100 sacks of Class A cement and had good circulation through the total plugging procedure.
1508948892 2017-10-25 Plug / Plug Back No Violations Plugging contractor has removed two inch flow line from old well site to the existing 100 Bbl. tank. Line was purged to remove any water or oil that might have been in line. No sign of any contamination.
1550843295 2019-2-21 0:00: FR No Violations
1807277127 2017-10-03 Plug / Plug Back No Violations Measured the top of the cement of the second plug at 306 feet deep. Witnessed the installation of 60 sacks of class a cement through tubing. Cement was witnessed at surface at this final plug.
283237147 2017-3-17 0:00: PW No Violations