34-127-24832

Well Details

Well ID: 34-127-24832
Loading map...
Country: United States
State: Ohio
County: Perry
Municipality: Coal Township
Operator Name: SCHMELZER PLUGGING LLC
Well Pad ID:
Farm/Lease Name: HOCKING VALLEY PROD CO
License Status: Producing
License Date: 1980-08-20
Spud Date: 1980-09-19
Spud Drilling Contractor:
Final Drill Date: 1980-09-21
Well Total Depth: 3444.00 ft
Configuration: Vertical
Latitude: 39.570000
Longitude: -82.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-08-20 182 BELDEN & BLAKE CO GeoDate 8/20/80
Original Spud 1980-09-19
Completed 1980-09-21
Reached Total Depth 1980-09-21
CO 1995-11-02 2573 JOHNSON M & GINGERICH M GeoDate 8/20/80
CO 1996-04-18 5460 JOHNSON MIKE GeoDate 8/20/80
Change of Owner 2014-04-30 Operator changed from 5460, JOHNSON MIKE to 8565, SCHMELZER PLUGGING LLC
Last Compliance Report 2017-08-07
Record Last Modified 2017-08-07

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3315 3375 22
3315 3375 22
3315 3375 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 78000 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 WITCO CORP 5.00 212.00 365
1985 WITCO CORP 0.00 300.00 365
1986 WITCO CORP 0.00 172.00 365
1987 BELDEN & BLAKE CORPORATION 0.00 242.00 365
1996 JOHNSON MIKE 0.00 124.00 365
1999 JOHNSON MIKE 0.00 88.00 0
2000 JOHNSON MIKE 0.00 129.00 0
2002 JOHNSON MIKE 0.00 267.00 365
2003 JOHNSON MIKE 0.00 128.00 365
2004 JOHNSON MIKE 0.00 165.00 365
2005 JOHNSON MIKE 0.00 21.00 365
2006 JOHNSON MIKE 0.00 41.00 365
2007 JOHNSON MIKE 0.00 14.00 365
2008 JOHNSON MIKE 0.00 123.00 365
2009 JOHNSON MIKE 0.00 130.00 365
2011 JOHNSON MIKE 0.00 81.00 365
2012 JOHNSON MIKE 0.00 61.00 366
2013 JOHNSON MIKE 0.00 24.00 365
2014 JOHNSON MIKE 0.00 0.00 114
2015 SCHMELZER PLUGGING LLC 0.00 150.00 365
2016 SCHMELZER PLUGGING LLC 0.00 257.00 365
2017 SCHMELZER PLUGGING LLC 0.00 0.00 360
2018 SCHMELZER PLUGGING LLC 0.00 0.00 360

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 WITCO CORP Brine 0 365
1985 WITCO CORP Brine 26 365
1986 WITCO CORP Brine 9 365
1987 BELDEN & BLAKE CORPORATION Brine 54 365
1996 JOHNSON MIKE Brine 0 365
1999 JOHNSON MIKE Brine 0
2000 JOHNSON MIKE Brine 0
2002 JOHNSON MIKE Brine 0 365
2003 JOHNSON MIKE Brine 0 365
2004 JOHNSON MIKE Brine 0 365
2005 JOHNSON MIKE Brine 0 365
2006 JOHNSON MIKE Brine 0 365
2007 JOHNSON MIKE Brine 0 365
2008 JOHNSON MIKE Brine 0 365
2009 JOHNSON MIKE Brine 0 365
2011 JOHNSON MIKE Brine 0 365
2012 JOHNSON MIKE Brine 0 366
2013 JOHNSON MIKE Brine 0 365
2014 SCHMELZER PLUGGING LLC Brine 10 200
2015 SCHMELZER PLUGGING LLC Brine 3 365
2016 SCHMELZER PLUGGING LLC Brine 0 365
2017 SCHMELZER PLUGGING LLC Brine 100 360
2018 SCHMELZER PLUGGING LLC Brine 5 360

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1563068112 2008-2-25 0:00: AD No Violations
-2040216054 2013-4-3 0:00:0 AD No Violations 1.00
-2095316152 2013-4-3 0:00:0 PW No Violations 1.00
-2140350528 2020-6-10 0:00: PW No Violations 0.50
-382344355 2013-7-10 0:00: PW No Violations
-840007565 2017-5-31 0:00: PB No Violations 2.00
-98317373 2013-4-3 0:00:0 PW No Violations 1.00
0098317373 2013-04-03 Production Wells No Violations This well is capable of production. It has rods and 2 tubing in it. The valve is open to the production tank. There is 1-100 barrel tank at the tank pad. No identification, flow line needs replaced, dike needs fixed to prevent materials from escaping from it. Need a plug for back of tank. Will write up NOV for issues.
0382344355 2013-07-10 Production Wells No Violations This well is now in-compliance. All violations have been resolved.
0385707909 2017-05-31 Work Over Reconditioning No Violations I was on location today to see how the rig crew was getting along with this well. Mark Hines was on this well to service it but while they were servicing the well they found out the 4.5 inch diameter casing has separated at 2410 feet. At this time they can not get back to bottom with pipe. They will be running pipe back down the well to mill out whatever is in the way. At this time they think they will end up plugging the well.
0640402441 2006-01-12 Annular Disposal No Violations Checked AD for Columbus, AD not being used.
0714602907 2019-04-29 Annular Disposal Violations Noted Our records indicate that the Division has not received the Annular Disposal Annual Report (Form 205) that was due on April 15th for 2018, Please submit the Form 205 to the Division by 5/29/2019.
0840007565 2017-05-31 Plug / Plug Back No Violations I am accompanied by Regional Supervisor Dan Goins. Our findings match the inspectors previous report.
1200597466 2008-01-16 Annular Disposal Violations Noted An inspection if the well revealed ID not correct, no permit # and owners name is wrong.
1207320204 2008-04-02 Annular Disposal No Violations Follow-up on NOV, In-Compliance.
1452612753 2016-01-11 Production Wells Violations Noted My inspection today is on a well with the RBDMS status of producing. The well is equipped with 8.625 inch surface casing, 4.5 inch production casing, 2 inch tubing, and rods. The well is producing with a pump jack powered by an electric motor. The production equipment includes a 100 barrel tank within an earthen dike. During the time of my inspection the pump jack was pumping and the 100 barrel tank was dripping oil out of the top inlet of the tank. The location leaking on the tank is called the overflow line, which usually attaches to another tank. There is no other tank and no plug in it to prevent this overflow. The oil dripping out of the tank was accumulating to be about 2 inches in the dike. I called Schmelzer Plugging and they showed up 5 minutes after I called. When they showed up they shut off the pump jack. They claimed that the electric time clock malfunctioned and kept the pump jack pumping nonstop. I explained to them their violations. Schmelzer Plugging is to place a plug in the tank over flow inlet and clean up and properly dispose of the contaminants within the dike. They were given a week to correct their violations.
1452694308 2016-01-12 Production Wells No Violations This inspection is to follow up on a compliance notice 1452612753. Schmelzer Plugging removed the oil from within the dike and placed a plug in the top over flow inlet of the 100 bbl. tank. All issues have been resolved and the well is within compliance.
1496324949 2017-05-31 Plug / Plug Back No Violations Inspection with Eric Conrad, findings match Inspectors prior report.
1501696561 2017-08-02 Annular Disposal No Violations On site to witness MIT testing owner applied 340 psi and we monitored pressure for one hour with a two pound loss in pressure TEST PASSED.
1563068112 2008-02-25 Annular Disposal No Violations Follow-up on NOV, Non-Compliance.
2040216054 2013-04-03 Annular Disposal No Violations The annular disposal is not hooked up.
2095316152 2013-04-03 Production Wells Violations Noted There is no identification on the well or the tank. There needs to be one on one or the other. The dike needs fixed to meet SPCC. The ditches that are dug into it so fluid can drain need fixed. The flow line is almost rotted through and needs replaced. The valve on the back of the tank needs a plug in it.
385707909 2017-5-31 0:00: WR No Violations 2.00
640402441 2006-1-12 0:00: AD No Violations
714602907 2019-4-29 0:00: AD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0714602907 US-OH-128110 2019-05-09 Failure to file Annular Disposal Report
1200597466 US-OH-105254 2008-01-17 Failure to legibly identify well
1452612753 US-OH-112893 2016-01-22 Well operation causing pollution and contamination
1452612753 US-OH-112894 2016-01-22 No SPCC dike/or failure to keep dike free of water or oil
1452612753 US-OH-112895 2016-01-22 Failure to have required locks, bull plugs
2095316152 US-OH-121395 2014-04-23 Inadequate pipeline strength
2095316152 US-OH-121396 2014-04-23 Failure to legibly identify well
2095316152 US-OH-121397 2014-04-23 No SPCC dike/or failure to keep dike free of water or oil
2095316152 US-OH-121398 2014-04-23 Failure to have required locks, bull plugs

For data sources see[9]

References