34-127-25310

Well Details

Well ID: 34-127-25310
Loading map...
Country: United States
State: Ohio
County: Perry
Municipality: Pike Township
Operator Name: GAIA EXPLORATION LLC
Well Pad ID:
Farm/Lease Name: REICHLEY/SNYDER
License Status: Producing
License Date: 1981-08-31
Spud Date: 1981-10-20
Spud Drilling Contractor:
Final Drill Date: 1981-10-24
Well Total Depth: 3418.00 ft
Configuration: Vertical
Latitude: 39.720000
Longitude: -82.190000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-08-31 1383 OHIO L & M CO INC GeoDate 8/31/81
Original Spud 1981-10-20
Completed 1981-10-24
Reached Total Depth 1981-10-24
CO 1994-01-31 2573 JOHNSON M & GINGERICH M GeoDate 8/31/81
CO 1996-03-20 5425 GINGERICH MIKE GeoDate 8/31/81
Change of Owner 2008-06-04 Operator changed from 5425, GINGERICH MIKE to 1634, NORTHWOOD ENERGY CORP
Last Compliance Report 2018-04-19
Record Last Modified 2018-04-19

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3268 3297 15
3268 3297 15
3268 3297 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1095 Bbl 80000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 OHIO L & M CO INC 3198.00 493.00 0
1985 L & M PETROLEUM CO 2640.00 435.00 0
1986 L & M PETROLEUM CO 2161.00 424.00 365
1987 L & M PETROLEUM CO 1918.00 314.00 365
1990 OHIO L & M CO INC 916.00 92.00 365
1991 OHIO L & M CO INC 935.00 173.00 365
1992 JOHNSON M & GINGERICH M 571.00 196.00 152
1993 JOHNSON M & GINGERICH M 614.00 101.00 365
1994 JOHNSON M & GINGERICH M 1155.00 227.00 365
1995 JOHNSON M & GINGERICH M 1085.00 151.00 365
1996 GINGERICH MIKE 662.00 138.00 365
1997 GINGERICH MIKE 828.00 145.00 365
1998 GINGERICH MIKE 686.00 64.00 365
1999 GINGERICH MIKE 602.00 66.00 365
2000 GINGERICH MIKE 471.00 89.00 365
2001 GINGERICH MIKE 448.00 80.00 365
2002 GINGERICH MIKE 483.00 71.00 365
2003 GINGERICH MIKE 271.00 0.00 365
2004 GINGERICH MIKE 0.00 0.00 365
2005 GINGERICH MIKE 0.00 0.00 365
2006 GINGERICH MIKE 0.00 129.00 365
2007 GINGERICH MIKE 0.00 87.00 365
2008 NORTHWOOD ENERGY CORP 0.00 78.00 365
2009 NORTHWOOD ENERGY CORP 0.00 132.00 365
2010 NORTHWOOD ENERGY CORP 0.00 149.00 365
2011 NORTHWOOD ENERGY CORP 0.00 107.00 0
2012 NORTHWOOD ENERGY CORP 0.00 138.00 366
2013 NORTHWOOD ENERGY CORP 0.00 0.00 0
2014 NORTHWOOD ENERGY CORP 0.00 153.00 365
2015 NORTHWOOD ENERGY CORP 0.00 70.00 365
2016 NORTHWOOD ENERGY CORP 0.00 0.00 365
2017 NORTHWOOD ENERGY CORP 0.00 150.00 365
2018 NORTHWOOD ENERGY CORP 0.00 99.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 OHIO L & M CO INC Brine 0 0
1985 L & M PETROLEUM CO Brine 0 0
1986 L & M PETROLEUM CO Brine 0 365
1987 L & M PETROLEUM CO Brine 0 365
1990 OHIO L & M CO INC Brine 0 365
1991 OHIO L & M CO INC Brine 0 365
1992 JOHNSON M & GINGERICH M Brine 110 152
1993 JOHNSON M & GINGERICH M Brine 105 365
1994 JOHNSON M & GINGERICH M Brine 95 365
1995 JOHNSON M & GINGERICH M Brine 105 365
1996 GINGERICH MIKE Brine 98 365
1997 GINGERICH MIKE Brine 12 365
1998 GINGERICH MIKE Brine 200 365
1999 GINGERICH MIKE Brine 200 365
2000 GINGERICH MIKE Brine 100 365
2001 GINGERICH MIKE Brine 150 365
2002 GINGERICH MIKE Brine 150 365
2003 GINGERICH MIKE Brine 0 365
2004 GINGERICH MIKE Brine 0 365
2005 GINGERICH MIKE Brine 0 365
2006 GINGERICH MIKE Brine 250 365
2007 GINGERICH MIKE Brine 0 365
2008 GINGERICH MIKE Brine 0 365
2009 NORTHWOOD ENERGY CORP Brine 341 365
2010 NORTHWOOD ENERGY CORP Brine 400 365
2011 NORTHWOOD ENERGY CORP Brine 147
2012 NORTHWOOD ENERGY CORP Brine 376 366
2013 NORTHWOOD ENERGY CORP Brine 144 0
2014 NORTHWOOD ENERGY CORP Brine 120 365
2015 NORTHWOOD ENERGY CORP Brine 316 365
2016 NORTHWOOD ENERGY CORP Brine 728 365
2017 NORTHWOOD ENERGY CORP Brine 1676 365
2018 NORTHWOOD ENERGY CORP Brine 1285 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1025614097 2005-9-15 0:00: AD No Violations
-1759444080 2016-5-16 0:00: PW No Violations 1.00
-1813183296 2020-7-6 0:00:0 PW No Violations 0.50
-364591722 2007-11-7 0:00: AD No Violations
-450322584 2007-9-26 0:00: AD No Violations
-562580215 2005-10-13 0:00 AD No Violations
0085539646 2014-01-24 Production Wells No Violations This well is capable of production. The well has a pumping unit on it with rods and 2 tubing in it. The valves are open to the production tank. The identification for the well is located at the tank pad. There are no violations at this time.
0271695582 2013-02-28 Production Wells No Violations This well is capable of producing. It has a pumping unit on it with rods and 2 tubing. The valves are open to the tank pad. Identification is legible on the tank and meets 1501-9-9-05.
0364591722 2007-11-07 Annular Disposal No Violations Follow-up on NOV, In-Compliance.
0450322584 2007-09-26 Annular Disposal Violations Noted An inspection of the well revealed well is capable of producing and has produced in past few weeks. ID on tank battery not legible, needs rewrote. Landowner is complaining about no house gas, told them to contact well owner.
0557543897 2014-01-31 Production Wells No Violations This well is a production well. The well is capable of producing with a pumping unit on it attached to the rods. The rods are ran inside of 2 tubing. The production valves are open that hook to the flow lines. The flow lines are connected at the tank pad. The identification for the well is located on the tank. There are no violations at this time.
0562580215 2005-10-13 Annular Disposal No Violations Follow-up on NOV, In-Compliance.
0667138952 2017-03-16 Production Wells No Violations Today I was on location to do a field inspection on this well. The well appears to be in production at this time. The well has a pumping unit on it with rods and 2 inch diameter tubing in it. The valves are open from the well to the tank pad. The identification for the well is located on the pumping unit. There are no violations at this time.
0708738547 2019-02-13 Production Wells No Violations Today I was on location to do a field inspection on this well. The well appears to be in production at this time. The well has a pumping unit on it with rods and 2 inch diameter tubing in it. The valves are open from the well to the tank pad. The identification for the well is located on the pumping unit. There are no violations at this time.
0932565471 2005-06-29 Annular Disposal No Violations No violations. NEW LAT & LONG
1025614097 2005-09-15 Annular Disposal Violations Noted An inspection of the well revealed the well to be idle and appears to have not produced for several years according to landowner. No ID at the well or tanks, electric line low needs hung up, and dike does not meet SPCC requirements.
1362155889 2013-02-28 Annular Disposal No Violations I checked to see if the annular disposal was hooked up for Columbus. It was not hooked up.
1397625429 2017-12-13 Temporary Abandoned Annular Disposal No Violations I am on location today to check the annular disposal for Columbus. The annular disposal is not hooked up on this well.
1409255345 2014-08-27 Production Wells No Violations I returned to this well to do a follow-up inspection on the production tank needing replaced and the contaminated soil. Northwood has set a new production tank and has expanded there tank pad. All of the contaminated soil has been removed from the location and new soil has been put down.
1759444080 2016-05-16 Production Wells No Violations This well appears to be in production. The well has a pumping unit on it with rods and 2 tubing in it. The valves are open from the well to the tank pad. The identification for the well is located on the pumping unit. There are no violations at this time.
271695582 2013-2-28 0:00: PW No Violations 0.50
557543897 2014-1-31 0:00: PW No Violations 1.00
667138952 2017-3-16 0:00: PW No Violations 1.00
708738547 2019-2-13 0:00: PW No Violations 0.50
85539646 2014-1-24 0:00: PW No Violations 1.00
932565471 2005-6-29 0:00: AD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0450322584 US-OH-124875 2007-10-01 Failure to legibly identify well
1025614097 US-OH-100458 2005-09-19 Well shall be plugged
1025614097 US-OH-100459 2005-09-19 Failure to legibly identify well
1025614097 US-OH-100460 2005-09-19 No SPCC dike/or failure to keep dike free of water or oil
1025614097 US-OH-100461 2005-09-19 General Safety
1025614097 US-OH-100462 2005-09-19 Urban - failure to meet tank battery setbacks from mandatory pooled property

For data sources see[9]