Well Details

Well ID: 34-127-25869
Loading map...
Country: United States
State: Ohio
County: Perry
Municipality: Harrison Township
Operator Name: JOHNSON OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: OHIO POWER CO
License Status: Producing
License Date: 1983-01-11
Spud Date: 1983-04-23
Spud Drilling Contractor: DYNAMIC DRILLING
Final Drill Date: 1983-04-26
Well Total Depth: 3640.00 ft
Configuration: Vertical
Latitude: 39.800000
Longitude: -82.120000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-01-11 Issued Date 12/30/82 Expired Date 6/28/83 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03640 Proposed Drill Depth 03640
Original Spud 1983-04-23
Completed 1983-04-26
Reached Total Depth 1983-04-26
Completion Report Received 1983-06-07
Construction Permit Expires 1983-06-28
CO 1983-09-08 182 BELDEN & BLAKE CO GeoDate 1/11/83
CO 1995-11-02 2573 JOHNSON M & GINGERICH M GeoDate 1/11/83
CO 1996-04-18 5460 JOHNSON MIKE GeoDate 1/11/83
Change of Owner 2019-03-26 Operator changed from 5460, JOHNSON MIKE to 10354, JOHNSON OIL & GAS LLC
Record Last Modified 2019-03-26

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 0 0
0 0
2006-09-11 3512 3554 11
3512 3554 11
0 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 45000 Gal 60000 FRAC: 45MG FLUID, 60M SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 ENTERPRISE ENERGY CORP 8852.00 283.00 0
1985 ENTERPRISE ENERGY CORP 5989.00 155.00 360
1986 BELDEN & BLAKE CORPORATION 1766.00 72.00 365
1987 BELDEN & BLAKE CORPORATION 1923.00 0.00 365
1988 BELDEN & BLAKE CORPORATION 2622.00 112.00 229
1990 BELDEN & BLAKE CORPORATION 1233.00 0.00 343
1991 BELDEN & BLAKE CORPORATION 1140.00 0.00 365
1992 BELDEN & BLAKE CORPORATION 949.00 0.00 353
1993 BELDEN & BLAKE CORPORATION 981.00 0.00 281
1994 BELDEN & BLAKE CORPORATION 425.00 0.00 74
1995 BELDEN & BLAKE CORPORATION 0.00 0.00 366
1996 BELDEN & BLAKE CORPORATION 0.00 90.00 366
1999 JOHNSON MIKE 430.00 15.00 0
2000 JOHNSON MIKE 750.00 16.00 0
2001 JOHNSON MIKE 173.00 0.00 365
2002 JOHNSON MIKE 468.00 0.00 365
2003 JOHNSON MIKE 431.00 0.00 365
2005 JOHNSON MIKE 253.00 0.00 365
2006 JOHNSON MIKE 309.00 0.00 365
2007 JOHNSON MIKE 143.00 0.00 365
2008 JOHNSON MIKE 128.00 0.00 365
2009 JOHNSON MIKE 53.00 0.00 365
2010 JOHNSON MIKE 0.00 0.00 365
2011 JOHNSON MIKE 83.00 0.00 365
2012 JOHNSON MIKE 86.00 0.00 366
2013 JOHNSON MIKE 69.00 0.00 365
2014 JOHNSON MIKE 16.00 0.00 365
2015 JOHNSON MIKE 12.00 0.00 365
2016 JOHNSON MIKE 461.00 0.00 365
2017 JOHNSON MIKE 210.00 0.00 365
2018 JOHNSON MIKE 143.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 ENTERPRISE ENERGY CORP Brine 150 0
1985 ENTERPRISE ENERGY CORP Brine 28 360
1986 BELDEN & BLAKE CORPORATION Brine 37 365
1987 BELDEN & BLAKE CORPORATION Brine 0 365
1988 BELDEN & BLAKE CORPORATION Brine 30 229
1990 BELDEN & BLAKE CORPORATION Brine 4 343
1991 BELDEN & BLAKE CORPORATION Brine 2 365
1992 BELDEN & BLAKE CORPORATION Brine 0 353
1993 BELDEN & BLAKE CORPORATION Brine 7 281
1994 BELDEN & BLAKE CORPORATION Brine 0 74
1995 BELDEN & BLAKE CORPORATION Brine 28 366
1996 BELDEN & BLAKE CORPORATION Brine 0 366
1999 JOHNSON MIKE Brine 0
2000 JOHNSON MIKE Brine 0
2001 JOHNSON MIKE Brine 0 365
2002 JOHNSON MIKE Brine 0 365
2003 JOHNSON MIKE Brine 0 365
2005 JOHNSON MIKE Brine 0 365
2006 JOHNSON MIKE Brine 0 365
2007 JOHNSON MIKE Brine 0 365
2008 JOHNSON MIKE Brine 0 365
2009 JOHNSON MIKE Brine 0 365
2010 JOHNSON MIKE Brine 0 365
2011 JOHNSON MIKE Brine 0 365
2012 JOHNSON MIKE Brine 0 366
2013 JOHNSON MIKE Brine 0 365
2014 JOHNSON MIKE Brine 0 365
2015 JOHNSON MIKE Brine 0 365
2016 JOHNSON MIKE Brine 0 365
2017 JOHNSON MIKE Brine 0 365
2018 JOHNSON MIKE Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1041576744 2009-12-11 0:00 PW No Violations
-1556215581 2006-4-26 0:00: PW No Violations
-1875147502 2020-5-8 0:00:0 PW No Violations 0.50
-2015548543 2006-2-24 0:00: PW No Violations
-521058575 2017-4-11 0:00: PW No Violations 1.00
-791346156 2013-12-23 0:00 PW No Violations 1.00
-82717682 2009-11-23 0:00 PW No Violations
0000PL6984 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0082717682 2009-11-23 Production Wells No Violations Follow-up on NOV, Non-Compliance, no action taken to comply with NOV. Will send the company a letter notifying them of the violation.
0521058575 2017-04-11 Production Wells No Violations I was on location today to do a field inspection on this well. The well has a pumping unit on it with rods, 1.5 inch diameter tubing and 4.5 inch diameter casing . The well has 1-210 barrel storage tank back on location with a vertical separator. The valves are open from the wellhead to the production tank. The identification for this well is located at the tank pad. There are no violations at this time.
0621237123 2018-08-03 Production Wells No Violations I was on location today to do a field inspection on this well. The well has a pumping unit on it with rods and 1.5 inch diameter tubing and 4.5 inch diameter casing . The well has 1-210 barrel storage tank back on location with a vertical separator. The valves are open from the wellhead to the production tank. The identification for this well is located at the tank pad. There are no violations at this time.
0791346156 2013-12-23 Production Wells Violations Noted There is no identification for this well. The ID needs to have the OWNER, WELL NAME, WELL NUMBER, PREMIT NUMBER, TOWNSHIP, COUNTY AND EMERGENCY CONTACT NUMBER. This needs to be at either the well or at the tank pad.
0885296171 2009-11-03 Production Wells Violations Noted An inspection of the well revealed ID not legible and needs rewrote on production tank.
1029501437 2014-02-26 Production Wells No Violations On February 26, 2014, I accompanied inspector Justin Smith to this well site to perform a follow-up inspection. Proper identification information has been posted at the well, which brings this well into compliance.
1041576744 2009-12-11 Production Wells No Violations Follow-up on NOV, In-Compliance.
1122701232 2017-04-11 Production Wells No Violations On my inspection today, I am accompanied by inspector Smith. Our inspection revealed oil and gas well equipped with vertical separator, and a drip. Tank battery with 1-210 barrel steel tank.
1393595244 2014-02-26 Production Wells No Violations On February 26, 2014, I accompanied inspector Justin Smith to this well site to perform a follow-up inspection. Proper identification information has been posted at the well, which brings this well into compliance.
1556215581 2006-04-26 Production Wells No Violations Follow-up on NOV, In-Compliance.
2015548543 2006-02-24 Production Wells Violations Noted An inspection of the well revealed according to production records well is idle, no production reported since 2003, and no ID at the well or tank battery. Chart on meter last date 4-3-01
27765667 2020-4-20 0:00: PW No Violations 0.50
621237123 2018-8-3 0:00:0 PW No Violations 0.50
885296171 2009-11-3 0:00: PW No Violations
PL6984 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0791346156 US-OH-129011 2014-03-10 Failure to legibly identify well
0885296171 US-OH-130083 2009-11-04 Failure to legibly identify well
2015548543 US-OH-120471 2006-02-27 Failure to legibly identify well
2015548543 US-OH-120472 2006-02-27 Well shall be plugged

For data sources see[9]