34-127-27235

Well Details

Well ID: 34-127-27235
Loading map...
Country: United States
State: Ohio
County: Perry
Municipality: Clayton Township
Operator Name: R C POLING CO INC
Well Pad ID:
Farm/Lease Name: COTTERMAN
License Status: Final Restoration
License Date: 2015-03-30
Spud Date: 2000-12-18
Spud Drilling Contractor: PROFESSIONAL WELL SVC-PWS
Final Drill Date: 2001-01-02
Well Total Depth: 5312.00 ft
Configuration: Vertical
Latitude: 39.800000
Longitude: -82.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-11-09 236 POLING R C CO INC Proposed Formation KNOX (MAY NOT PRODUCE CLINTON) Issued Date 11/9/00 Expired Date 11/9/01 6:00:00 AM
Original Spud 2000-12-18 RBDMS Rec
Completed 2001-01-02 RBDMS Rec
Reached Total Depth 2001-01-02 RBDMS Rec
Completion Report Received 2001-02-08 RBDMS Rec
APP 2010-06-16 Proposed Formations:ROSE RUN, Issued Date:6/16/2010, Expired Date:6/16/2011 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
APP 2011-06-28 Proposed Formations:ROSE RUN, Issued Date:6/28/2011, Expired Date:6/27/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
APP 2014-02-03 Proposed Formations:ROSE RUN, Issued Date:2/3/2014, Expired Date:2/3/2016 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
APP 2015-03-30 Proposed Formations:ROSE RUN, Issued Date:3/30/2015, Expired Date:3/29/2017 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2015-09-08 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec
Construction Permit Expires 2017-03-29 RBDMS Rec

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 R C POLING CO INC 1902.00 1454.00 365
2002 R C POLING CO INC 2839.00 2283.00 365
2003 R C POLING CO INC 2100.00 2432.00 365
2004 R C POLING CO INC 2850.00 2398.00 365
2005 R C POLING CO INC 2575.00 1732.00 365
2006 R C POLING CO INC 2575.00 1850.00 365
2007 R C POLING CO INC 2175.00 1244.00 365
2008 R C POLING CO INC 0.00 0.00 365
2009 R C POLING CO INC 0.00 0.00 365
2010 R C POLING CO INC 0.00 0.00 365
2011 R C POLING CO INC 0.00 0.00 365
2012 R C POLING CO INC 0.00 0.00 366
2013 R C POLING CO INC 0.00 0.00 365
2014 R C POLING CO INC 0.00 0.00 365
2015 R C POLING CO INC 0.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 R C POLING CO INC Brine 80 365
2002 R C POLING CO INC Brine 0 365
2003 R C POLING CO INC Brine 0 365
2004 R C POLING CO INC Brine 0 365
2005 R C POLING CO INC Brine 0 365
2006 R C POLING CO INC Brine 0 365
2007 R C POLING CO INC Brine 3290 365
2008 R C POLING CO INC Brine 6895 365
2009 R C POLING CO INC Brine 75 365
2010 R C POLING CO INC Brine 0 365
2011 R C POLING CO INC Brine 35 365
2012 R C POLING CO INC Brine 0 366
2013 R C POLING CO INC Brine 0 365
2014 R C POLING CO INC Brine 180 365
2015 R C POLING CO INC Brine 125 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1231166049 2013-9-4 0:00:0 PW No Violations 1.00
-1295518036 2016-8-3 0:00:0 FR No Violations 1.00
-1319817248 2010-7-29 0:00: PW No Violations 1.00
-1419923885 2014-6-2 0:00:0 PW No Violations 1.00
-1888281759 2014-2-7 0:00:0 AM No Violations 0.20
-433959256 2006-3-9 0:00:0 PW No Violations
-651920327 2016-11-1 0:00: FR No Violations
0056731397 2015-12-22 Plug / Plug Back No Violations I was on location to do a final restoration on this well. During my inspection I found that all the steal flow line had not been removed yet and the separator was still on location. I talked with Zack Poling and he said he would get it taken care of.
0176172986 2008-10-09 Production Wells No Violations No violations.
0197843905 2014-06-26 Production Wells No Violations Mark Hines has his service rig on this well. Mr. Poling is having them put the well back into production. They are running 3 in the well on a packer at this time.
0433959256 2006-03-09 Production Wells No Violations No violations.
0441249347 2009-02-26 Production Wells No Violations No violations.
0527215561 2015-09-10 Plug / Plug Back No Violations I was onsite to witness the rest of the plugging on this well. When I arrived on location Kenny was pulling the tubing back out of the well. He set down at 1200ft when running the tubing down to set the plugs. We ran the tools down to see if we could knock the bridge out but had no luck. We then ran the tubing back down and hooked up Formation to circulate the hole clean. We were able to clean up the hole and trip the tubing down to set the Clinton plug from 3240-3040. We then pulled up to set the Lime plug from 2440-2240. We pulled the tubing out of the well then hooked onto the 5.5. They pulled out 2 joints then set the Berea plug from 1125-965. The 5.5 was pulled up to the bottom of the surface to set a 200ft bottom of surface plug. We then topped the well off with a 200ft surface plug.
0557425158 2003-06-17 Preliminary Restoration No Violations
0651920327 2016-11-01 Final Restoration No Violations The final restoration meets 1509.072B.
1231166049 2013-09-04 Production Wells Violations Noted The permit to plug this well has expired. I went out to check the status of this well. It is still out of production. I talked with Mr. Poling and he told me he is thinking of putting it back in production. If he does not he will renew the permit to plug the well. The company plans on putting well back in production. I notified the company and told them to have it back in production by January or they will have to apply for a plugging permit and plug the well.
1295518036 2016-08-03 Final Restoration No Violations I was on location today to do the final restoration of this well. The final restoration meets 1509.072B.
1319817248 2010-07-29 Production Wells No Violations No violations at this time.
1419923885 2014-06-02 Production Wells No Violations I talked with Dick Poling about the status of this well. Mr. Poling said he plans on having a service rig on this well in the next 2 weeks. He is going to attempt to put the well back into production. If the well does not show any signs of capable production he plans on plugging the well.
1441717881 2015-09-08 Plug / Plug Back No Violations Wrights well service on site. They have pulled out the 3 casing and left the 5.5 casing. A 35 bottom hole plug was set thru tubing. The plug did not circulate.
1441806062 2015-09-09 Plug / Plug Back No Violations I was onsite today to witness the plugging of this well. Kenny was unable to find a free spot in the 5.5 to rip the pipe the day before. So today Appalachian is on site to run a bond log to find free pipe. The bond log showed the pipe has cave in all the way up to 1200ft. I had Appalachian run a 10 shot 10ft gun down to the Clinton so we could set a plug there. They ran back in the well to perforate the Lime. Then Appalachian ran a cutter down to 1200ft to cut the 5.5 off. Kenny picked up on the casing to make sure it was free then set it back down. The 1.5 tubing will be ran in the well to set the Clinton plug. Formation cementing will be set up for tomorrow.
176172986 2008-10-9 0:00: PW No Violations
1888281759 2014-02-07 Administrative Inspection No Violations Received the plugging permit for this well.
1950353075 2014-03-05 Production Wells No Violations I talked with Mr. Poling about this well just to remind him the well will need to be put back in production or plugged. He let me know that as soon as the weather is better and it is dry they would be servicing the well. If they did not like the results they would plug the well while the rig was still on location.
197843905 2014-6-26 0:00: PW No Violations 2.00
441249347 2009-2-26 0:00: PW No Violations
527215561 2015-9-10 0:00: PB No Violations
557425158 2003-6-17 0:00: PL No Violations
56731397 2015-12-22 0:00 PB No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1231166049 US-OH-106211 2014-07-01 Well shall be plugged
1231166049 US-OH-106212 2014-07-01 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[8]

References