Well Details
Well ID: 34-127-27298
|
|
Country: United States
|
State: Ohio
|
County: Perry
|
Municipality: Bearfield Township
|
Operator Name: R C POLING CO INC
|
Well Pad ID:
|
Farm/Lease Name: MILLIGAN
|
License Status: Final Restoration
|
License Date: 2014-07-28
|
Spud Date: 2005-09-09
|
Spud Drilling Contractor: PROFESSIONAL WELL SVC-PWS
|
Final Drill Date: 2005-09-15
|
Well Total Depth: 4017.00 ft
|
Configuration: Vertical
|
Latitude: 39.710000
|
Longitude: -82.050000
|
For data sources see[1]
Well History
APP
|
2005-08-16
|
Proposed Formations:CLINTON, Issued Date:8/16/2005, Expired Date:8/16/2006 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
|
Original Spud
|
2005-09-09
|
RBDMS Rec
|
Completed
|
2005-09-15
|
RBDMS Rec
|
Reached Total Depth
|
2005-09-15
|
RBDMS Rec
|
Completion Report Received
|
2006-01-31
|
RBDMS Rec
|
APP
|
2008-09-02
|
Proposed Formations:BEREA, Issued Date:9/2/2008, Expired Date:9/2/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
|
APP
|
2014-07-28
|
Proposed Formations:CLINTON, Issued Date:7/28/2014, Expired Date:7/27/2016 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
|
Plugged/Abandoned
|
2014-10-07
|
RBDMS Rec
|
Construction Permit Expires
|
2016-07-27
|
RBDMS Rec
|
Record Last Modified
|
2017-02-15
|
RBDMS Rec
|
For data sources see[2]
Perforation Treatments
2006-04-05
|
3844
|
3950
|
42
|
|
3844
|
3950
|
42
|
|
3844
|
3950
|
42
|
For data sources see[3]
Stimulations Data
For data sources see[4]
Production Data
For data sources see[5]
[6]
Waste Data
For data sources see[7]
[8]
Inspection Data
Inspections Performed
-2038267826
|
2007-9-14 0:00:
|
PW
|
No Violations
|
|
-276588928
|
2014-9-30 0:00:
|
PB
|
No Violations
|
3.00
|
-5206456
|
2014-10-7 0:00:
|
PB
|
No Violations
|
5.00
|
0005206456
|
2014-10-07
|
Plug / Plug Back
|
No Violations
|
I was onsite to witness the plugging of this well. The tubing was set at 1550ft for the first plug. We were unable to get the tubing back down to the Lime formation. After the pipe was shot off the hole caved in down the 5.5. We tried to wash the tubing down for 2days but only gained 120ft. We set a 250ft plug at 1550 then pulled out 250ft of pipe and set another 200ft plug to cover the Berea. The tubing was then pulled up to the bottom of the surface casing and a 200ft plug was set. The tubing was then pulled up to set the 200ft surface plug. The cement stayed at the surface with no signs of settling. The well is now plug.
|
0141107473
|
2007-07-20
|
Drill / Deepen / Reopen
|
No Violations
|
Follow-up on NOV, Non-Compliance, will issue the company a letter explaining the violation and failure to comply with NOV.
|
0276588928
|
2014-09-30
|
Plug / Plug Back
|
No Violations
|
Kenny Wright has moved in on this well to plug it. They have pulled out the rods and tubing from the well. The tubing was tallied then ran back in to a depth of 3960ft to set the bottom plug. The tubing was then pulled back out so they could get set up to rip the 5.5
|
1127134624
|
2005-09-12
|
Drill / Deepen / Reopen
|
No Violations
|
Checked drlg rig
|
1153857737
|
2015-06-11
|
Plug / Plug Back
|
No Violations
|
I returned to this well to do the final restoration on it. I was not able to pass the final restoration because the wellhead has not been cut off. I called Dick Poling and left a message for him to call me back. I will let him know this still needs to be done.
|
141107473
|
2007-7-20 0:00:
|
DD
|
No Violations
|
|
1412339824
|
2014-10-03
|
Plug / Plug Back
|
No Violations
|
I was onsite to witness the plugging of this well. The rig crew had to run the tubing back down to the Lime to set the plug. They were unable to get the tubing down to the lime so they had Formation Cementing hook up to the tubing and try to wash the pipe down. The tubing would not wash down. They are shutting down for the day and will try to clean up the hole on Monday. We talked about possibly bringing out a mud pump and power swivel.
|
1412774879
|
2014-10-07
|
Plug / Plug Back
|
No Violations
|
I received a request from inspector Justin Smith. I was asked to cover this plug job. Formation Cementing on location setting the plugs. I witnessed the lime/isolation plug and the bottom of surface plugs. Inspector Smith will fill out the plugging report.
|
1442094995
|
2007-05-31
|
Drill / Deepen / Reopen
|
Violations Noted
|
An inspection of the well revealed the Preliminary Restoration does not meet the 1509.072 requirements, lease road and well site need restored.
|
1521582996
|
2015-10-21
|
Final Restoration
|
No Violations
|
The final restoration meets 1509.072B.
|
1800714726
|
2007-10-19
|
Preliminary Restoration
|
No Violations
|
Restoration meets 1509.072(A) requirements.
|
2038267826
|
2007-09-14
|
Production Wells
|
No Violations
|
Follow-up on NOV, In-Compliance.
|
Violations Commited
1442094995
|
US-OH-112850
|
2007-05-31
|
|
Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
|
For data sources see[9]