Well Details

Well ID: 34-129-20088
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Wayne Township
Operator Name: LAYLINE OIL AND GAS LLC
Well Pad ID:
Farm/Lease Name: BURKE-MAY UNIT (SWIW # 2)
License Status: Active Injection
License Date: 2011-05-10
Spud Date: 1995-08-28
Spud Drilling Contractor: OHIO ENERGY ASSETS
Final Drill Date: 1996-02-29
Well Total Depth: 3998.00 ft
Configuration: Vertical
Latitude: 39.580000
Longitude: -83.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1994-12-29 Issued Date 12/29/94 Expired Date 12/29/95 Acres 0020000 Tool Type RTAF Proposed Formation KNOX-MT. SIMON Proposed Depth 03998 Proposed Drill Depth 03998
Original Spud 1995-08-28 DeepestFMTN agrees with DGS-reference PG-2
CO 1995-10-25 1901 REDMAN E C /REDMAN OIL CO GeoDate 10/25/95
Conversion to Injector 1995-10-25
Salt Water Injection Well 1995-10-25 Issued Date 10/25/95 Expired Date 10/24/96 Acres 0020000 Tool Type NT Proposed Formation MT. SIMON Proposed Depth 03998 Proposed Drill Depth 03998
Storage Well 1995-10-25 Issued Date 10/25/95 Expired Date 10/24/96 Acres 0020000 Tool Type NT Proposed Formation MT. SIMON Proposed Depth 03998 Proposed Drill Depth 03998
CO 1996-02-29 1901 REDMAN E C /REDMAN OIL CO GeoDate 12/29/94
Completed 1996-02-29 DeepestFMTN agrees with DGS-reference PG-2
First Injection 1996-02-29 DeepestFMTN agrees with DGS-reference PG-2
Reached Total Depth 1996-02-29 DeepestFMTN agrees with DGS-reference PG-2
Completion Report Received 1996-04-22 DeepestFMTN agrees with DGS-reference PG-2
Annulus Pressure Monitoring Approved 1998-12-03 DeepestFMTN agrees with DGS-reference PG-2
Change of Owner 2001-12-20 Operator changed from 1901, REDMAN E C /REDMAN OIL CO to 6091, OHIO ENERGY ASSETS, INC.
APP 2011-05-10 Proposed Formations:ROSE RUN & MT. SIMON, Issued Date:5/10/2011, Expired Date:5/9/2013 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:SWD, Proposed Well Class:SWIW
Construction Permit Expires 2013-05-09 DeepestFMTN agrees with DGS-reference PG-2
Change of Owner 2013-10-07 Operator changed from 6091, OHIO ENERGY ASSETS, INC. to 9177, DART OIL & GAS OHIO LLC
Last Compliance Report 2014-04-18 DeepestFMTN agrees with DGS-reference PG-2
Change of Owner 2018-05-22 Operator changed from 9177, DART OIL & GAS OHIO LLC to 10136, LAYLINE OIL AND GAS LLC
Record Last Modified 2018-05-22 DeepestFMTN agrees with DGS-reference PG-2

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-05-10 2460 3988 0
2460 3988 0
2460 3988 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 20 1000 Gal 0

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1008719979 2018-12-13 0:00 SC No Violations 2.00
-1038793321 2005-6-23 0:00: SW No Violations
-1070418973 2013-3-27 0:00: SW No Violations
-1129814231 2006-3-7 0:00:0 SW No Violations
-1146023080 2008-9-10 0:00: SW No Violations
-1252745571 2016-6-29 0:00: SW No Violations 1.00
-138236377 2020-5-26 0:00: SW No Violations 2.50
-1383361639 2020-1-7 0:00:0 SW No Violations 3.00
-1425379890 2008-6-11 0:00: SW No Violations
-1622720696 2016-3-7 0:00:0 SW No Violations 1.50
-1629141244 2011-5-23 0:00: SW No Violations
-1659822765 2003-10-21 0:00 SW No Violations
-1741889779 2006-10-26 0:00 SW No Violations
-1962216202 2018-6-4 0:00:0 SW No Violations 2.00
-2001891793 2007-9-13 0:00: SW No Violations
-2013832088 2020-7-16 0:00: SW No Violations 3.00
-2087232211 2016-7-28 0:00: SW No Violations 1.00
-217448482 2018-8-28 0:00: SW No Violations 1.00
-349724336 2008-4-8 0:00:0 PW No Violations
-446743182 2007-4-11 0:00: SW No Violations
-556020081 2018-3-22 0:00: SW No Violations 2.00
-623875497 2019-4-24 0:00: SW No Violations 2.10
-700234326 2012-8-8 0:00:0 SW No Violations
-718799673 2005-10-4 0:00: SW No Violations
-74385180 2018-12-4 0:00: SW No Violations 2.30
-785072816 2019-10-24 0:00 SW No Violations 2.00
-808527862 2019-2-8 0:00:0 SW No Violations 3.50
-917118005 2017-9-6 0:00:0 SW No Violations 0.50
-986138662 2014-4-10 0:00: SW No Violations 10.00
0001248i34 2001-07-05 Salt Water Injection Well No Violations NO VIOLATIONS NOTED. WEATHER CONDITIONS 80 WITH PARTLY CLOUDY. WELL IN OPERATION.
0001248i99 2001-10-31 Salt Water Injection Well No Violations NO VIOLATIONS NOTED THIS DATE. WEATHER CONDITIONS: SUNNY AND 64 DEGREES.
000UIC1733 1998-10-07 Salt Water Injection Well No Violations 1501: 9-3-06 (H) IDENTIFICATION
000UIC1734 1998-10-07 Salt Water Injection Well No Violations 1509.22 STORAGE AND DISPOSAL
000UIC1735 1998-10-07 Salt Water Injection Well No Violations 1501: 9-3-04 (A) PREVENT CONTAMINATE
000UIC1736 1998-10-07 Salt Water Injection Well No Violations 1501: 9-3-05 (A)(7) CONSTRUCT & OPERATE
000UIC1793 1999-07-19 Salt Water Injection Well No Violations 1509.22(D); 1501: 9-3-06 ID AND POLLUTION
000UIC1820 2000-02-22 Salt Water Injection Well No Violations 1501: 9-3-04 PREVENT CONTAMINATE
000VER1049 1998-09-11 Production Wells No Violations
001248i299 2002-03-18 Salt Water Injection Well No Violations WEATHER CONDITIONS: Cloudy &48 degrees. No Violations Noted this date.
001248i375 2002-05-01 Salt Water Injection Well No Violations Inspection revealed owner needs or repair and/or replace the liner at the storage tanks. Liner has holes in it that could lead to possible pollution and contamination if fluids are allowed to rise to that level. Owner needs to advise the division as to what actions they are going to take place and on what date repairs are to begin.
001248i395 2002-05-16 Salt Water Injection Well No Violations Conference with Joe Melville with Ohio Energy Assets, Inc. in regards to making repairs to the liner at this location. We discussed the options that needed to be done to make the liner liquid tight. Joe does not want to replace the entire liner due to cost. His plain is to take a twelve (12) foot 30 mil liner and place it from the top of the dike in to the flat area of the dike area and use silicon caulk (three beads) to join the existing liner to the new twelve (12) foot section.
0074385180 2018-12-04 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. The injection line and injection tubing valves are open. The annulus is on zero. The injection tubing is on zero. I contacted Ron Richards about the need to keep positive pressure on the annulus. Ron said that he will put some pressure on the annulus.
0082796930 2011-03-22 Salt Water Injection Well No Violations - On site for repairs to well. New Halliburton R-4 packer and 4 replacement tubing with liner.

- Operator has excavated a pit and place liner in it to contain overflow of material from well. - Producer Service Corp. on site to acidize well, 2,000 gal of 20% acid and 80 barrels of fresh water were used, water when on vacuum during pumping. - New Halliburton R-4 packer with 2 pin removed and lined tubing place into well, blockage at 2,600 feet, several try to bypass blockage were unsuccessful. Remove tubing and packer from well. - Weather condition partly sunny temp. 70s

0090552156 2012-03-20 Salt Water Injection Well No Violations - ID at well Annulus pressure 440 Injection pressure 0

Weather Sunny Temp 80s

0130120996 2017-06-02 Salt Water Injection Well No Violations Salt water injection well inspection. The injection tubing was on vacuum, the annulus pressure was 420 PSI. No violations noted.
0138012332 2003-07-02 Salt Water Injection Well No Violations - Pump operating while on site, operator injecting gauge reading 720 psi. Unable to get injecting gauge off to take reading.
0197971106 2010-08-10 Salt Water Injection Well No Violations - ID on well Injection pressure 140 annulus pressure 420 Water meter 7356 gallons = 175 barrels
0217448482 2018-08-28 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks , injection pump, injection pressure and annulus pressure. Identification is posted at the surface facility and the well site.
0349724336 2008-04-08 Production Wells No Violations - ID on building at well, injection pump not operating while on site.

- Annulus pressure 300 injection 0 - Water meter reading at the Stevenson tank battery 6188910 gallons = 147,355 barrels

0446743182 2007-04-11 Salt Water Injection Well No Violations - Well injection 0 annulus 320 PSI. Injection pump not operating while on site. Water meter reading at Stevenson # 36 4560240 gallons = 108,577barrels.
0453164541 2017-03-03 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the containment dike and the well site. The containment dike has 8 inches of water from rain events over the past few days. I called Eric Allen and he is scheduling to have the water pumped into the tank. Eric also informed me that they have installed a submersible pump in the tank as an injection pump.
0464746059 2012-06-14 Salt Water Injection Well No Violations - ID on well, injection pump not operating while on site. Area clean and free of debris.

- Annulus pressure 540 PSI injection pressure 0

0556020081 2018-03-22 Salt Water Injection Well No Violations The salt water injection well had 2 psi on the annulus. The injection tubing was on vacuum. The dike was relativity free of fluids. I called Mr. Larry Howdyshell to have the annulus pressure increased. Mr. Howdyshell said it would be done on 3.23.18.
0623875497 2019-04-24 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
0668225203 2017-07-13 Salt Water Injection Well No Violations Quarterly UIC inspection. The annulus pressure was 410 PSI, the injection tubing was 0 PSI. Legible identification was posted. No violations noted.
0700234326 2012-08-08 Salt Water Injection Well No Violations - ID on well and tank, Annulus pressure 580 injection pressure 0 Water meter reading 3587060 gallons = 85,406 barrels
0718799673 2005-10-04 Salt Water Injection Well No Violations - Injection pump not operating while on site.

- Water meter reading at the Stevenson 1634360 gallons = 38,913 barrels. - Injection 140 PSI Annulus 260 PSI

0764740442 2015-09-23 Salt Water Injection Well No Violations Containment dike has approximately 8 of water in it. High range Quantab revealed 1925 ppm Cl. The unloading pad drain plug has been removed and the pad is dry. I called and talked to Eric Allen about the fluid in the containment dike. I told him that the dike must be kept free of fluids. He told me that they did not have capacity in the tank for the water. I advised that they need to develop a plan to keep the dike free of fluids.
0767040441 2007-09-11 Salt Water Injection Well No Violations - Berry Well Service working on well. Tubing pulled from well. 2 joint of unlined tubing had holes in them. Packer was set on compression.

- Producer Service Company acidize well. - New Haliburton R-4 packer place into well, lined tubing placed back in well except last 4 joints are unlined. Packer to be set on tention. Stop for the day, ran out of daylight.

0793719358 2011-06-30 Salt Water Injection Well No Violations - ID on well, annulus pressure 460 injection pressure 0 on vacuum. Water meter reading 693980 gallons = 16,501 barrels
0808527862 2019-02-08 Salt Water Injection Well No Violations Mini test on the annulus at 375 psi for 15 minutes with no loss in pressure.
0839971067 2010-01-05 Salt Water Injection Well No Violations - ID at well on small yard barn. Injection pump not operating while on site. Annulus pressure 440 injection 0 on vacuum. Operator has replace small valves with new steel shut off valve.

- No water meter due to cold weather conditions.

0842373554 2018-12-05 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted at the containment dike and well.
0917118005 2017-09-06 Salt Water Injection Well No Violations My inspection today revealed the saltwater injection well had 249 psi on the annulus and 0 psi on the injection tubing.
0962230064 2015-11-02 Salt Water Injection Well Violations Noted Inspected the containment dike, tanks, unloading pad, injection pump, injection pressure and annulus pressure. Identification is posted at the well and facility. The containment dike has 13 visible holes in the liner ranging from 1/2 to 6 1/2. All holes were marked with orange marking tape. Eric Allen was notified and came to the well site to discuss the holes and methods to repair the liner.
0986138662 2014-04-10 Salt Water Injection Well No Violations Witnessed the release of the packer and the removal of one sub joint of tubing (4.10). Circulated fresh water and inhibitor then set the packer at 2426 with 34,000 lbs tension. Tested the annulus 5 times with a steady loss in pressure despite attempts to pull more tension, release air from the annulus. Company decided to trip tubing and packer out of well. Packer rubber had multiple cuts. Replaced packer with a rebuilt Halliburton R-4 (lined). Witnessed the packer being ran back in the well. On the 2nd joint of tubing the service rig elevators opened and the tubing (2joints) and packer were dropped into the well. Company plans to fish out the tubing and packer on 4-11-14.
1008719979 2018-12-13 Surface Facility Construction No Violations Repairs have been made to the containment dike plastic liner. Holes in liner have been patched.
1028677030 2002-10-16 Salt Water Injection Well No Violations Inspection revealed no violations noted this date. OWNER NEEDS TO REMOVE FLUIDS FROM THE DIKE AROUND THE STORAGE TANKS. WEATHER CONDITIONS: CLOUDY AND 50 DEGRES.
1038793321 2005-06-23 Salt Water Injection Well No Violations - On site for inspection, Pump operating while on site, Pressure reading tubing 380 psi annulus 420 psi.
1042561199 2003-01-14 Salt Water Injection Well No Violations 1. Tanks are ok, pit liner in good shape.
1047743332 2009-06-10 Salt Water Injection Well No Violations - ID on well, Annulus pressure 200 injection 500 pump operating while on site. Small amount of fluid on pump vault. Water meter reading 8058980 gallons =191880 barrels.
1051630218 2003-04-29 Annular Disposal No Violations - On site for inspection, well site is claen and well maintain.

- Well pummping when arrive on site operator injection gauge 840psi. - Check pressure with my gauge annulus 300psi. / pump not operating when cheking injection pressure 100psi

1061380759 2003-08-20 Salt Water Injection Well No Violations - pump not operating while on site, pump house clean and in good condittion.

- meter reading 332311 and 779303 - Tank liner in good condition.

1070418973 2013-03-27 Salt Water Injection Well No Violations - ID at well and Tank, Tank dike area free of water and debris. Annulus pressure 500 Injection pressure 0 vacuum.

- Weather condition Cloudy Temp 30s Wet ground conditions.

1070469303 2003-12-03 Salt Water Injection Well No Violations Pump not operating while on site.

- Flow meter not operating, operator has install flow meter at tank battery. Tank area clean and well maintain.

1074015865 2004-01-13 Salt Water Injection Well No Violations - Pump not operating while on site, Flow meter not working. Operator has remove flow meter at tanks, operator is doing repairs at tanks to lines. Tank area clean and well maintained, dikes in good condition.
Injection 0 PSI    Annulus 140 PSI
1075830138 2004-02-03 Salt Water Injection Well No Violations Injection well area well maintain, pump house clean. Pump not operating while on site.

- Tank area clean small amount of water in dike. - Meter 1423 gal. = 34 barrels

1086198913 2004-06-02 Salt Water Injection Well No Violations - Injection pump operating when arrived on site.

- Operator injection gauge reading 600 psi - Annulus 200 psi injection pump off 0 psi - Meter reading at pump 701888 = 16711 barrels meter reading at tank 1945 = 46 barrels - One production tank has hole at the bottom, operator has removed tank connection and tank is empty.

1091722505 2004-08-05 Salt Water Injection Well No Violations Pump operating while on site.

Unable to take injection reading, annulus reading 160 PSI

Weather Sunny Temp Mid 70s
1097755530 2004-10-14 Salt Water Injection Well No Violations - Annulus psi 0 injection psi 0 check pressure with pump running and with pump shut off, no change in pressures. Call Jeff Fry and reports this to him, he recommend to kept a check on well and to watch for different pressure and a negative pressure on annulus.

- Previous pressure Aug. 04 annulus 160 psi / June 04 annulus 200 psi Feb. 04 annulus 320 psi - Weather light rain Light fog. Temp high 50s

1100117409 2016-04-12 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the facility and well site. The containment dike has approximately 6 of water in it (rain event last night).
1106703824 2005-05-03 Salt Water Injection Well No Violations - Well is out of service, tubing laying on ground new packer in pump building.

- Met with Joe Melville, he didnt know when service rig would be available to put well back into operation.

1106781872 2005-01-26 Salt Water Injection Well No Violations Pump not operating while on site.

Annulus pressure 420 psi 0 on injection meter reading 939741 = 22374 barrels Steven water tanks disconnected and meter removed

1112718795 2005-04-05 Salt Water Injection Well No Violations Well inspection annulus 800 psi injection 0 Pump not operating while on site.

Meter reading 187637 gal = 4467 barrels

1117804569 2005-05-06 Salt Water Injection Well No Violations New packer was set and tested today. Well operator had begun running packer and tubing before I was on site. They pulled packer back out so it could be witnessed. 2 3/8 inch tubing was placed back in hole and packer was set at 3724 ft. Pressure test held at 1150 psi for 15 minutes and passed.
1129814231 2006-03-07 Salt Water Injection Well No Violations - Pump not operating while on site, ID on pump house.

- injection 0 psi Annulus 300 psi - Water meter at Stevenson #2 is 2806580 gallons = 66,823 barrels - Weather Sunny Temp 40s

1132199317 2012-10-18 Salt Water Injection Well No Violations - On site for inspection of newly constructed unloading pad. The pad is located between the two dikes that contain the water tanks and the production tanks. The pad is sloped to contain any spills and to drain into the concrete vault.
The operator has install a vault that will receive the water from the unloading pad drain. All areas around the pad and vault has been graded.  

- ID tank and well.

1138109707 2006-01-10 Salt Water Injection Well No Violations Injection pump operating while on site, ID in place.
Injection pressure 720  annulus pressure 380  water meter not working.
1146023080 2008-09-10 Salt Water Injection Well No Violations - ID on well and tank. Injection pump not operating while on site.

- Annulus pressure 260 injection 140

1149686618 2006-06-07 Salt Water Injection Well No Violations - Inspection of well, pump not operating while on site.

- Annulus pressure 420 injection pressure 0 - Water meter 3243860 gallons = 77,234 Barrels

1168440112 2007-01-09 Salt Water Injection Well No Violations - Well injection pressure 0 annulus presure 300

- ID on well, pump not operating while on site.

1177481179 2011-03-23 Salt Water Injection Well No Violations - Berry Well Service made several runs into the well with an impression tool to locate blockage in the well. Blockage still exists.
1181215981 2007-06-07 Salt Water Injection Well No Violations -Injection pump not operating while on site. Injection pressure 0 (on vacuum) annulus 0.

- Will contact operator to has annulus pressure up.

1190044070 2007-09-12 Salt Water Injection Well No Violations - Producer Service Corp. pumped 5 gallons of inhibitor and fresh water though 2 3/8 tubing circulate to surface between tubing and 4 1/2 casing.

- Service rig crew tried to set packer but unable to set. Pull tubing from well, packer unscrews and dropped to bottom of well. Rig crew place tubing back in well and tried to reconnect to packer. Pull tubing unable to retrieve packer.

1200491535 2008-01-16 Salt Water Injection Well No Violations - Pump discharge line disconnected from well.

Annulus pressure 420 injection 0 - Area around well clean and vegetation where pit was dug for servicing well this past summer.

1210i10573 2002-04-02 Salt Water Injection Well No Violations Well is operating. Tank battery liner has deteriorated from the weather and has numerous holes where exposed. Fluid will not be allowed above this. Dike liner will need repairs during warmer weather. Liner is no longer liquid tight at maximum capacity.
1210i1057378 2002-4-2 0:00:0 SW No Violations
1217888976 2015-04-29 Salt Water Injection Well No Violations UIC inspection. The annulus side had 550 PSI, the injection side was 0 PSI.
1231270862 2009-01-06 Salt Water Injection Well No Violations - Injection pump not operating while on site. Injection pressure 0 Vacuum, Annulus pressure 220

- Weather rain Temp 30

1233106008 2011-04-18 Salt Water Injection Well No Violations - On site for inspection of site for addition conditions for current injection facilities. No addition requirements are need at this time.
1248i299 2002-3-18 0:00: SW No Violations
1248i34 2001-7-5 0:00:0 SW No Violations 1.00
1248i375 2002-5-1 0:00:0 SW No Violations
1248i395 2002-5-16 0:00: SW No Violations
1248i62543 2001-09-05 Salt Water Injection Well No Violations NO VIOLATIONS NOTED THIS DATE. FLOW METER IS IN BARRELS. WEATHER CONDITIONS IS SUNNY AND 71 DEGREES.
1248i6254360 2001-9-5 0:00:0 SW No Violations 1.00
1248i99 2001-10-31 0:00 SW No Violations
1252745571 2016-06-29 Salt Water Injection Well No Violations Inspected the containment dike, tanks, unloading pad, injection pressure and annulus pressure. Identification posted at the well and facility. The injection pump has been removed from the facility.
1291741995 2010-12-07 Salt Water Injection Well No Violations - ID at well, Annulus pressure 420 injection 0 injection line valve closed.

- New building constructed over injection pump. - Weather temp 15 partly sunny frozen ground.

130120996 2017-6-2 0:00:0 SW No Violations 3.00
1303228709 2011-03-21 Salt Water Injection Well No Violations - Well has loss mechanical integrity, Berry Well Service has rig up over the well. Tubing and packer were pulled from the well and tallied. The first 4 joint of tubing were unlined, this is where the well loss integrity. The packer appear to have no damage to it. Work will continue on 3/22/2011

- Weather conditions Cloudy with intermittent showers temp 70s

1306705163 2020-1-23 0:00: SC No Violations 3.00
1306865813 2011-05-18 Salt Water Injection Well No Violations - New 4 1/2 inch casing was placed into well on 5/18/2011 and cemented 300 feet from 2440 to 2140.

- On site, tallie tubing and place rotary bit on 2 3/8 tubing to drill out cement plug in casing and to check for open well. Circulate fresh wash in the well, pull tubing from well.

1307627503 2011-05-20 Salt Water Injection Well No Violations Producer Well Service pump 1000gal of fresh water with 20% acid into well. Tallie tubing and install new R-4 Halliburton packer (2 pins removed) in well to a depth of 2,444.09 feet. Measurement was to the center of packer. Pump 5 gallon of inhibitor and 1,000 gallons of fresh water into well and circulate to the annulus. Set packer 14,000 string weight and pull 28,000 psi, packer slip in well, try test but failed, Operator try to release packer but failed. Decision was to wait to Monday 5/23/2011 and try to release packer and pull from well for inspection.
1317924346 2011-10-06 Salt Water Injection Well No Violations - Annulus pressure 360 injection pressure o on vacuum ID at well
1328644569 2012-02-07 Salt Water Injection Well No Violations - Annulus pressure 400 Injection pressure 0 on Vacuum

- ID at well area clean of debris.

1346967256 2012-09-06 Salt Water Injection Well No Violations Accompanied Mike Mitchell MRI 3 on inspection of the injection well facilities and checking injection and annulus pressures. Reviewed with Joe Melville his plans to pour a new concrete unloading pad and set a new tank for the containment of the unloading drain. Joe is installing a new stainless steel injection pump.
1348599688 2012-09-09 Salt Water Injection Well No Violations Joint inspection with Jon Scott of MRM. The operator is currently constructing a shed over the pump at the tank battery. One new fiberglass tank placed in dike area. Dike area free of water. The operator is in the process of installing a unloading pad and vault for pad.

- ID on well and tank. Injection pressure 0 on vacuum annul pressure 520 Water meter reading 3775250 gallons.

1349283505 2012-09-27 Salt Water Injection Well No Violations - On site for inspection of newly constructed unloading pad. The pad is located between the two dikes that contain the water tanks and the production tanks. The operator will install a vault that will receive the water from the unloading pad drain. The concrete vault is on location. The operator will contact when the vault is to be placed in the ground.
1358767377 2019-04-29 Salt Water Injection Well No Violations The inspection of this salt water injection well revealed the injection tubing had 33 psi and the annulus pressure was 340 psi. No leaks were observed and legible identification was posted.
1359034286 2013-01-24 Salt Water Injection Well No Violations - ID at well

- Injection pump has been disconnected due to cold weather conditions. - Annulus pressure 540 injection 0 Water meter has been removed due to freezing weather conditions. - Weather condition partly sunny temp 15

1368036186 2013-05-08 Salt Water Injection Well No Violations - ID at well and tank. Dike area clean and free of water. Unloading pad clean and free of water.

- Annulus pressure 580 Injection pressure 0 Vacuum, injection pump not operating while on site. - Weather condition; partly sunny Temp. 70s, Wet ground conditions

1372859103 2013-07-03 Salt Water Injection Well No Violations - ID at well and Tank, Tank dike area free of water and debris. Annulus pressure 520 Injection pressure 0 vacuum.

- Unloading pad free of debris - Weather condition Cloudy Temp 80s Wet ground conditions.

138012332 2003-7-2 0:00:0 SW No Violations
1384702794 2006-11-02 Salt Water Injection Well No Violations - Met with operator Joe Melville, injection pump put back into service today.

- Injection pressure 580 annulus 280.

1393531800 2014-02-27 Salt Water Injection Well No Violations - ID on well and tanks, Dike area free of debris, five 210 barrel tank in the dike area.

- Annulus pressure 500 injection pressure 0 on vacuum. - Water meter reading 7245 gallons - Unloading pad free of water and debris - Tank location entry 39.57270 -83.00156 - Weather condition partly cloudy temp 20s windy ground condition frozen

1396987997 2014-04-08 Salt Water Injection Well No Violations Witnessed installation of new Halliburton R-4 packer (lined) and used lined tubing that was tested by Tec star. Ran 2427 of tubing. Packer set at 2430. Circulated fresh water and inhibitor to surface prior to setting the packer. Packer set at 22,000 over string weight. Tested annulus at 890 psi for 15 minutes with no loss in pressure.
1397157853 2014-04-09 Administrative Inspection No Violations Received a call from company that the pressure on the annulus dropped off over night. They tried to pressure up the annulus and the pressure dropped off at a fast rate. They want to release the packer and remove a sub joint of tubing and reset the packer and test again. Job scheduled for 4-10-14.
1397510556 2014-04-14 Salt Water Injection Well No Violations Witnessed tubing and rebuilt packer being ran into the well. Set packer at 2430. Filled annulus and tested. Test failed. Attempted 7 total tests while pulling joints out of the well. Reseating the packer. All attempts resulted in the same drop in pressure while testing. Company plans on tripping out of the well and evaluating the tubing and packer.
1397586070 2014-04-15 Salt Water Injection Well No Violations Service rig released packer and pulled tubing and packer out of the well. Rig crew found pieces of plastic that were in the collar threads on a few joints of tubing. There were no visible areas on the packer to indicate a problem. Tubing is stacked at well site. Lined pit has been emptied.
1397689731 2014-04-16 Salt Water Injection Well No Violations Witness tubing and packer being ran into well. Packer had a 4.95 tail joint of tubing. A Pump Off Plug set at 3,000 lbs was installed on the bottom of the tail joint. Halliburton R-4 packer (lined) was rebuilt. Ran used 2/38 lined tubing. Tubing was tested at ten joint intervals during installation. Found one defective joint of tubing. Attempted multiple times at increasing pressure to release the pump off plug. Attempts were not successful. Shut down operations for night.
1397757345 2014-04-17 Salt Water Injection Well No Violations Rig crew pulled the tubing and packer out of the well. The tubing was full of water. They found tubing liner inserts that were broken and a few that were swollen due to pressure. The pump off plug was half way out. The 4 tail joint was full of flakes and sediment. Witnessed tubing and packer (rebuilt Halliburton R-4 lined packer) being ran back into well. Circulate fresh water (25.50 barrels with 2 gallons inhibitor) prior to setting packer. Packer set at 2429, (24,000 over string weight). Tested at 900 psi for 15 minutes with no loss.
1401888907 2014-06-04 Salt Water Injection Well No Violations - On site for UIC inspection, ID on well and tank

- Annulus pressure 1,000 psi Injection pressure 0 on vacuum -Water meter reading 33562 barrels - Dike area free of debris - Weather condition cloudy Temp 68 Damp to Wet ground conditions

1402228663 2020-1-15 0:00: SW No Violations 6.50
1409252153 2014-08-28 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, annulus pressure and injection pressure. Identification posted.
1411492203 2014-09-23 Salt Water Injection Well No Violations - Inspection, ID on well and tank

- Annulus pressure 940 PSI Injection pressure 0 - Water meter reading 75,858 barrels - Dike area free of debris, five fiberglass 210 barrel tank in dike area. - Unloading pad free of debris, vault empty -

1422636633 2015-01-30 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, flow meter, annulus pressure and injection pressure. Injection tubing master valve is closed and has a threaded bolt with a nut installed to prevent the valve from being opened. Identification posted at the well and the containment dike. Containment dike and unloading pad have a thin layer of ice with snow on top.
1425379890 2008-06-11 Salt Water Injection Well No Violations - Area clean of debris, well was service last fall, new packer and tubing place into well.

- ID on out building at well which houses the injection pump. - Annulus pressure 340 psi injection 0 psi - water meter at Stevenson 6602690 gallons = 157,206 barrels.

1442515039 2015-09-16 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Accompanied by UIC Geologist. Measured containment dike. Containment dike had water in it and the unloading pad had a plug installed in the drain. The unloading pad was full of water due to the plug. I talked to Eric Allen about the need to keep the containment dike free of fluids and the need to have the unloading pad functional as a containment area.
1444844569 2015-10-14 Salt Water Injection Well No Violations Compliance notice follow up inspection. Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. The containment dike is free of fluids. The unloading pad drain is not plugged and is open to the pad vault.
1447762511 2015-11-16 Salt Water Injection Well No Violations Compliance Notice # 962230064 Follow-up Inspection. All 13 holes in the liner have been repaired. The containment dike is free of fluids. Inspected the injection pump, unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the facility and the well site.
1449167542 2015-12-03 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. A 1 hole has been chewed in the liner by a rodent. The dike had 6 of water in it. I talked to Eric Allen and he is aware of the hole and will be patching the liner today when he pumps out the dike water.
1479921997 2016-11-21 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification posted at the surface facility and well site. The injection pump is not on site.
1494639049 2015-06-22 Salt Water Injection Well No Violations UIC inspection. The annulus had 18 PSI, the injection pressure was 0 PSI.
1515782521 2019-7-30 0:00: SW No Violations 3.00
1536683992 2018-10-03 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted at the well and facility. The containment dike is free of fluids. A 2 inch plastic line has been installed from the 210 barrel production tank battery to the containment dike and is connected to the line flowing into the injection pump inlet. I talked to Ron Richards and he told me that the line is temporary and that after a new treatment for the tanks he will connect the 2 inch line to a tank in the containment dike.
1549992533 2019-02-05 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike has approximately 2 inches of ice.
1582902236 2020-2-27 0:00: SW No Violations 2.50
1604222509 2019-9-27 0:00: SW No Violations 3.00
1622720696 2016-03-07 Salt Water Injection Well No Violations UIC injection. The annulus pressure was 460 PSI, the injection pressure was 10 PSI.
1629141244 2011-05-23 Salt Water Injection Well No Violations - Berry well Service doing service work. Packer release by shearing set pins, pull packer and tubing from well.

- Install rebuilt packer with 1 pin removed, 2 foot tail pipe installed on end of packer, tallie tubing, install to 2,431 feet. Circulate 5 gallons of inhibitor and 1,075 gallons of fresh water. Set packer 14,000 string weight and pull 20.000 for total of 34.000 psi. pressure well to 800 psi and test, failed lost more than 5% in 10 minutes, replace ball valve on well head and repressure well to 860 psi and held with no lost of pressure for 15 minutes, bleed annulus pressure down to 480 psi.

1659822765 2003-10-21 Salt Water Injection Well No Violations - Injection pump operaring while on site, pump house clean and well maintain.

- Flow reading 204329 = 4864.9 - Injection psi 740 annulus psi 220 - Tank area clean and dike well maintain.

1676951340 2009-03-31 Salt Water Injection Well No Violations - well injection presure 0 annulus pressure 120. Well ID, injection pump not operating while on site.

- Water meter at Stevenson tank battery meter reading 7778520 gallons = 18,520 Barrels.

1741889779 2006-10-26 Salt Water Injection Well No Violations - ID on well, injection pump disassemble for repairs.

- injection pressure 0 annulus pressure 280 water meter 3691870 gallons = 87,901 barrels

1832672995 2005-06-07 Salt Water Injection Well No Violations - Joint inspection with Jeff Fry,

- Injection pump not operating while on site. - New packer, recondition tubing and integrity check done in May 2005 witness by Dave Crow. - 80 psi on annulus 0psi on injection, contacted operator of low annulus pressure. - Water meter reading 228005 = 5428 barrels

1918103636 2015-03-02 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection line, injection pressure and annulus pressure. Injection tubing master valve is closed and locked. Identification is posted at the well site on the side of the storage building and at the containment dike on a post.
1947201618 2016-01-25 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the facility and the well site.
1962216202 2018-06-04 Salt Water Injection Well No Violations Inspected the containment dike, tanks, unload pad, injection pump, injection pressure and annulus pressure. Identification is posted at the well site and surface facility. The containment dike is free of fluids.
197971106 2010-8-10 0:00: SW No Violations
1981761543 2010-03-17 Salt Water Injection Well No Violations - ID at well, injection pump not operating while on site. Annulus pressure 340 injection pressure 0 on vacuum. Water meter reading 8688350 gallons = 206865 barrels.
2001891793 2007-09-13 Salt Water Injection Well No Violations - Service rig crew finish pulling 2 3/8 tubing from well. Install new Halliburton R-4 packer, remove 2 shear pins place packer and tubing back into well.

- Set packer in tension, string weight 12,000 lbs and line weight pulled to a total of 34,000 Lbs. - Sweeney Service Inc. from New Concord, Ohio pressured well annulus to 1260 psi, pressure held for 15 minutes with no lost. Pasted test, and operator bleed pressure down to 500 psi.

2078216879 2009-10-27 Salt Water Injection Well No Violations - ID at well, injection pump not operating while on site, Annulus pressure 160 injection 0 on vacuum.
2087232211 2016-07-28 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. The injection pump is not on site. The injection line is disconnected from the facility within the containment dike. The containment dike is free of fluids.
2091380704 2004-10-06 Preliminary Restoration No Violations Preliminary inspection done by previous inspector, done on paper report.

Well is use for salt water injection.

453164541 2017-3-3 0:00:0 SW No Violations 1.70
464746059 2012-6-14 0:00: SW No Violations
561939095 2019-10-28 0:00 SC No Violations 0.50
668225203 2017-7-13 0:00: SW No Violations 2.00
764740442 2015-9-23 0:00: SW No Violations 1.00
767040441 2007-9-11 0:00: SW No Violations
793719358 2011-6-30 0:00: SW No Violations
82796930 2011-3-22 0:00: SW No Violations
839971067 2010-1-5 0:00:0 SW No Violations
842373554 2018-12-5 0:00: SW No Violations 1.00
90552156 2012-3-20 0:00: SW No Violations
959870141 2020-8-13 0:00: SW No Violations 3.00
962230064 2015-11-2 0:00: SW No Violations 3.00
UIC1733 1998-10-7 0:00: SW No Violations
UIC1734 1998-10-7 0:00: SW No Violations
UIC1735 1998-10-7 0:00: SW No Violations
UIC1736 1998-10-7 0:00: SW No Violations
UIC1793 1999-7-19 0:00: SW No Violations
UIC1820 2000-2-22 0:00: SW No Violations
VER1049 1998-9-11 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0962230064 US-OH-131012 2015-12-04 Pits not liquid tight/Improper construction or use

For data sources see[5]