34-129-20095

Well Details

Well ID: 34-129-20095
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Circleville Township
Operator Name: LAYLINE OIL AND GAS LLC
Well Pad ID:
Farm/Lease Name: PRITCHARD-WARNER UNIT
License Status: Active Injection
License Date: 1996-05-20
Spud Date: 1995-08-15
Spud Drilling Contractor: OHIO ENERGY ASSETS
Final Drill Date: 1995-08-18
Well Total Depth: 2637.00 ft
Configuration: Vertical
Latitude: 39.630000
Longitude: -82.960000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1995-05-11 1901 REDMAN E C /REDMAN OIL CO GeoDate 5/11/95
Oil and Gas 1995-05-11 Issued Date 5/11/95 Expired Date 5/10/96 Acres 0020000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth Proposed Drill Depth
CO 1995-06-06 1901 REDMAN E C /REDMAN OIL CO GeoDate 6/6/95
Oil and Gas 1995-06-06 Issued Date 6/6/95 Expired Date 6/5/96 Acres 0020000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth 02637 Proposed Drill Depth 02637
Original Spud 1995-08-15 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
Completed 1995-08-18 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
Reached Total Depth 1995-08-18 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
Completion Report Received 1995-11-03 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
CO 1996-05-20 1901 REDMAN E C /REDMAN OIL CO GeoDate 5/20/96
Conversion to Injector 1996-05-20
Salt Water Injection Well 1996-05-20 Issued Date 5/20/96 Expired Date 5/20/97 Acres 0020000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth Proposed Drill Depth
Storage Well 1996-05-20 Issued Date 5/20/96 Expired Date 5/20/97 Acres 0020000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth Proposed Drill Depth
Annulus Pressure Monitoring Approved 1996-07-31 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
First Injection 1996-08-28 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
Construction Permit Expires 1997-05-20 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
Change of Owner 2001-12-20 Operator changed from 1901, REDMAN E C /REDMAN OIL CO to 6091, OHIO ENERGY ASSETS, INC.
Last Compliance Report 2011-11-10 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96
Change of Owner 2013-10-07 Operator changed from 6091, OHIO ENERGY ASSETS, INC. to 9177, DART OIL & GAS OHIO LLC
Change of Owner 2018-05-22 Operator changed from 9177, DART OIL & GAS OHIO LLC to 10136, LAYLINE OIL AND GAS LLC
Record Last Modified 2018-05-22 CONVERTED TO SWIW RI/RL 6-10-95, CONVERT 5-25-96

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-05 2548 2558 4
2548 2558 4
2548 2558 4

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 1000 Gal 0 ACIDIZED W/1000 GAL GEL HCL

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1008283574 2004-10-5 0:00: SW No Violations
-1020718925 2008-4-8 0:00:0 SW No Violations
-1042975653 2015-9-16 0:00: SW No Violations 2.00
-1062534999 2003-4-3 0:00:0 SW No Violations
-1305552330 2020-8-24 0:00: SW No Violations 6.00
-1338708425 2019-9-16 0:00: SW No Violations 2.00
-139627299 2010-12-7 0:00: SW No Violations
-1429386347 2019-2-21 0:00: SW No Violations 0.60
-1482823611 2009-2-20 0:00: SW No Violations
-149184499 SW No Violations
-1503669102 2006-6-7 0:00:0 SW No Violations
-1555329845 2017-12-13 0:00 SW No Violations 0.40
-1610750614 2020-2-27 0:00: SW No Violations 1.10
-1699238845 2016-11-21 0:00 SW No Violations 1.50
-1713624721 2015-4-28 0:00: SW No Violations 1.00
-188333945 2005-1-26 0:00: SW No Violations
-206784827 2015-3-2 0:00:0 SW No Violations 1.00
-2095096269 2009-2-6 0:00:0 SW No Violations
-2146426590 2011-6-29 0:00: SW No Violations
-2146575421 2009-3-31 0:00: SW No Violations
-308897308 2015-11-16 0:00 SW No Violations 2.00
-329570543 2019-10-24 0:00 SW No Violations 0.70
-447367402 2015-11-4 0:00: SW No Violations 2.00
-561254622 2020-8-18 0:00: SW No Violations 8.70
-668978322 2018-3-15 0:00: SW No Violations 1.00
-702321145 2018-8-28 0:00: SW No Violations 1.00
-731196985 2010-8-10 0:00: SW No Violations
-809863148 2012-9-9 0:00:0 SW No Violations
-936729335 2017-3-16 0:00: SW No Violations 2.00
-984359217 2012-9-6 0:00:0 SW No Violations 0.50
0001248i55 2001-08-17 Salt Water Injection Well No Violations NO VIOLATIONS NOTED THIS DATE. WEATHER CONDITIONS 73 DEGREES AND MOSTLY SUNNY.
0001248i96 2001-10-31 Salt Water Injection Well No Violations NO VIOLATIONS NOTED THIS DATE. WELL NOT IN OPERATION. WEATHER CONDITIONS 54 DEGRES AND SUNNY.
000UIC1742 1998-11-13 Salt Water Injection Well No Violations 1501: 9-3-07 (D) EXCEED MAX. INJ PSI
000UIC1743 1998-11-13 Salt Water Injection Well No Violations 1509.03 RULES & REGULATIONS
000UIC1745 1998-12-22 Salt Water Injection Well No Violations 1501: 9-3-06 (H) REMOVE FLUID IN DIKE
001248i200 2002-01-31 Salt Water Injection Well No Violations WEATHER CONDITIONS: Cloudy and 66 Degrees. No Violations Noted This Date. Well is in operation.
001248i296 2002-03-18 Salt Water Injection Well No Violations WEATHER CONDITIONS: Cloudy and 44 degrees. No Violations noted.
001248i372 2002-05-01 Salt Water Injection Well Violations Noted ID sign at the storag tamks needs to be remarked.
001248i386 2002-05-13 Salt Water Injection Well No Violations Follow-up revealed ID posted at the tank battery. No other violations noted this date. WEATHER CONDIRIONS: Cloudy w/rain and 60 degrees.
001248i459 2002-07-30 Salt Water Injection Well No Violations Accompanied by Jeff Fry. Inspection revealed pressure on the tubing and annuals are both equal at 400 pounds. Owner need to check this to make sure there is not a failure down hole. August 1,2002 Follow up revealed well not running tubing pressure is 0 P.S.I. and annuals is 260 P.S.I..
0138592899 2014-06-03 Salt Water Injection Well No Violations - On site for UIC inspection, ID on well and tank

- Annulus pressure 520 psi Injection pressure 0 -Water meter reading 25,192 barrels - Dike area free of debris, unloading pad clean and free of debris - Weather condition partly sunny Temp 85 Humid Damp to Wet ground conditions

0139627299 2010-12-07 Salt Water Injection Well No Violations - Recheck well pressure, Annulus pressure 100 Injection 0

- injection pump not operating. - Water meter 42031 gallons = 1000 barrels - Weather Temp 13 Cloudy

0149184499 Salt Water Injection Well No Violations
0149250296 2009-02-10 Salt Water Injection Well No Violations - On site for tubing test. Sweeny well service pressure tubing to 1,000 psi, tubing string leaked off pressure, leaked 100 psi in 1 minute and 45 seconds.

- Operator will remove service rig from well due to weather conditions, and to see what the representative of the company that manufacture the tubing will do.

0188333945 2005-01-26 Salt Water Injection Well No Violations All well connected to dispose water are have been taken offline and water meters remove.

All dikes are free of water - injection pump not operating.

0206784827 2015-03-02 Salt Water Injection Well No Violations Inspected the containment dike, tanks, unloading pad, injection pressure and annulus pressure. Identification is posted on a post at the well and at the containment dike.
0245842169 2006-10-26 Salt Water Injection Well No Violations - ID at well and tank.

- Injection pressure 0 on vacuum, Annulus pressure 180

0308897308 2015-11-16 Salt Water Injection Well No Violations Compliance Notice # 447367402 Follow-up Inspection. All 6 holes in the liner have been repaired. The containment dike is free of fluids. Inspected the containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the facility and the well site.
0323180766 2018-12-05 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. The new containment dike sump pump is operating on a float switch.
0341562683 2009-02-05 Salt Water Injection Well No Violations - Berry Well Service replace rubber on Halliburton R-4 packer and replace 5 shear pins. Will put 18 joints of 2 3/8 lined tubing into well. Tubing liner insert couplers are one time use. Joe Melville has coupler insert on order and will have them overnight freight.
0343669874 2011-04-21 Salt Water Injection Well No Violations - well shut in due to flooding of the area. ID at tank and well area.
0376620595 2011-11-09 Salt Water Injection Well No Violations - Set packer to 2468 measurement from top of packer rubber. 5 gallons of inhibitor with fresh water, Lowry Well Treatment pressure annulus to 1,000 psi and held with no pressure loss.

Weather - Rain Temp. 57 Humidity 74% Barometric pressure 29.91 Dew point 49 wind 12mph SSE

0425825194 2007-06-07 Salt Water Injection Well No Violations - Injection pump not operating while on site. ID at well and tanks. Injection pressure 0 (vacuum), annulus pressure 380.
0447367402 2015-11-04 Salt Water Injection Well Violations Noted Inspected the injection pressure, annulus pressure, containment dike, tanks and unloading pad. Identification is posted at the well and facility. The containment dike liner has 6 holes ranging from 3/4 to 8 1/2. Hole locations were marked with orange marking tape. I called Eric Allen and told him about the holes in the dike liner. I also told him that the plastic is brittle. Replacing the liner is recommended. The containment must be water tight.
0491223378 2009-06-10 Salt Water Injection Well No Violations - Injection 0 psi on vacuum , annulus 460 psi.. Well ID and orange safety fence around well.

- Tank ID and injection pump not operating while on site, Tank area clean and unloading pad clean and free of water.

0518364039 2003-07-02 Salt Water Injection Well No Violations - Unable to connect gauge to injection side of well, valve will not close. Will contact operator to install new valve.

- Injection pump operating while at well, pressure at pump ~ 300psi pump shut down before reading was obtain. - Flow meter not working, will also bring this to operator attention.

0537112671 2008-01-16 Salt Water Injection Well No Violations - ID on well and tanks. Injection pump not operating while on site. Annulus pressure 320 psi and injection pressure 0 psi. water meter removed.

Weather partly sunny Temp low 20s light snow on ground.

0603871188 2009-02-19 Salt Water Injection Well No Violations - on site to pressure test tubing string in well, string was place into well with bull plug on the bottom.

- Representatives with OEA - Joe Melville, Berry Well Service - Bill Mitten and rig 2 crew with Mike Dickerson operator, Seal Tite - Matt Werner, Tech Star - Jack. - Tested tubing with highest pressure of 1280 psi and lowest 960 psi test passed except for one. - Removed tubing from well, Place Halliburton R-4 packer with 5 shear pins on bottom string, replace all seals (red) in tubing couplers and replace all internal PVC coupler, torque tubing to 900 Lbs. Six joint of tubing were replaced with new tubing from Tech Star.

0623076312 2009-02-03 Salt Water Injection Well No Violations - Berry Well Service removed 80 joints of 2 3/8 tubing from the well, tally of tubing 2,469.36 Packer was set at 2,471.55 measurement at top of rubber.

- New PVC lined 2 3/8 tubing placed into well PVC connector placed in collars of the tubing. Tally of pipe 2,469.42 packer at 2,471.59 measure at top of rubber. Halliburton R-4 packer with 2 shear pins removed. - Producer Well Service, service well, acid 20% 1,000 gallons. 5 Gallons of packer inhibitor with fresh water on back side of tubing. Pressure up well several time, but well unable to retain pressure that is require. Operator will replace well head, fitting and valves tomorrow 2/4/2009.

0632378703 2018-12-04 Surface Facility Construction No Violations Installing a new sump pump in the containment dike. The access to the injection well is flooded.
0668978322 2018-03-15 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 240 psi on the tubing and 25 psi on the annulus. The dike was free of fluids. Legible identification was posted.
0683386190 2004-10-05 Preliminary Restoration No Violations Well preliminary inspection was done by previous inspector.

- well is use as salt water injection well. - well has ID sign in place at well head.

0702321145 2018-08-28 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the well and facility. The containment dike has 8 inches of fluid in the low portion of the dike. There is a 1 inch black plastic line that has a gallon jug with holes attached and extends over the containment dike wall. This siphon system was not in use during the inspection. I tested the dike water with a high range Quantab. The results were 7.6 on the strip which is 3299 ppm Cl. There was an oil sheen observed as well. I called Ron Richards on 8-29-2018 at 12:30 pm and left a message stating that the dike water must be pumped into a tank for disposal in the injection well.
0731196985 2010-08-10 Salt Water Injection Well No Violations - ID at well and tank area. Injection pressure 0 on vacuum, annulus pressure 260. Orange safety fence around well head. Water meter reading 43469 gallons = 1,034 barrels. Dike area free of debris and height of berm has been increase. Unloading pad clean of debris.
0809863148 2012-09-09 Salt Water Injection Well No Violations - Joint inspection with Jon Scott of MRM. ID on well and tank. Dike area free of debris. Injection pressure 0 vacuum Annulus pressure 460
0906901750 2011-10-06 Salt Water Injection Well No Violations - Annulus pressure 340 injection pressure 0 on vacuum. ID at well and tank.

- Tank area free of water. - Injection line disconnected at tank area, water being pump to Justus #1

0920375530 2016-07-27 Salt Water Injection Well No Violations Inspected the containment dike, tanks, unload pad, injection pressure and annulus pressure. Identification posted. The well access road has been graded with geo fabric and stone applied. The containment dike is free of fluids.
0936729335 2017-03-16 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification is posted at the well and facility.
0984359217 2012-09-06 Salt Water Injection Well No Violations Accompanied Mike Mitchell MRI 3 on inspection of the injection well facilities and checking injection and annulus pressures.
1008283574 2004-10-05 Salt Water Injection Well No Violations Reading at well - annulus 220 psi / injection 0 psi. pump not operating while on site. Take reading from tanks for water injection. Warner #6 - 202 gal. = 4.8 barrels Warner # 1 &3 - 205 gal. = 4.9 bls. Pritchard #1 - 1121 gal. = 26.7bls. Pritchard # 3 - 767 gal. = 15.6 bls. Clutts # 2 - 657 gal. = 15.6 bls. Clutts # 1 & 3 - 590 gal. = 14.0 bls. Warner Justus # 1 - 2516 gal. = 59.9 bls. TOTAL 6058 gal 144.2 bls.
1012453330 2012-03-20 Salt Water Injection Well No Violations - Well ID and tanks ID. Annulus pressure 480 injection 0 Vacuum.

- Orange safety fence around well.

1020718925 2008-04-08 Salt Water Injection Well No Violations - ID on well and tanks. Injection pump operating while on site.

- annulus pressure 300 injection pressure 580 - Water meter total from other wells = 331,220 barrels - Operator has constructed new building for injection pump, unloading pad clean and no water standing.

1032281824 2002-09-16 Salt Water Injection Well No Violations No Violations noted this date. Well is running. Accompanied by Mike Mitchell. WEATHER CONDITIONS: Mostly sunny and 78 degrees.
1042573508 2003-01-14 Salt Water Injection Well No Violations Snow cover unable to liner.
1042975653 2015-09-16 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Accompanied by UIC Geologist. Measured containment dike. The injection tubing pressure gauge and needle valve were seized up. I called Company and the pumper came to the well site and replaced the needle valve on the injection tubing. I talked to the pumper about the recent replacement of injection line fittings. The needle valve on the injection tubing was measured at 7 7.5 off of the ground level. I requested that the 1/4 valve be relocated at an accessible height.
1048164262 2003-03-18 Salt Water Injection Well No Violations 1.) Operator had pulled tubing from well, tubing plug.

2.) New Pamco packer and tubing ran back into well set packer at 2486.7 ft. 3.) 5gal. Of HMIS 04 Severity scale Inhibitor to 60 bbls of water. 4.) Pressure annulus to 1,060 psi. Start test at 12:40 AM. / 12:45 psi 1,060 after 15 minute psi still 1,060 well passed MIT. Pressure needs to be min. of 755 psi. 5.) Joe Melville back pressure off to 360 psi/ well service done by Profession Well Service. 6.) Well is in compliance call Tom Tomatski to resolve chief order.

1061392193 2003-08-20 Salt Water Injection Well No Violations - At well operator injection gauge 280 psi, injection pump operating while taking reading on annulas. Annulas reading operator gauge 320 psi, ODNR gauge 360 psi.

- Take reading at tanks for water

  Warner # 1-3    8311 gal = 198  barrels
  Warner # 2         840 gal = 20  barrels
  Warner # 6       1662 gal = 40  barrels
   Clutts # 1-3      565 gal  = 13 barrels
  Clutts # 2          287 gal  =  7 barrels
  Jutus # 1           522 gal  =  7 barrels
  Pritchard # 1     404 gal  =  10 barrels
1062534999 2003-04-03 Salt Water Injection Well No Violations 1. Well is back in working order, sign posted.

2. Pump station OK pump not operating while on location.

1070459504 2003-12-03 Salt Water Injection Well No Violations Reading at well 80 psi annulus and 0 on injection, Temperature 27

- Pump not operating while on site. - Water reading taken at each tanks Warner - 1&3 8409 = 200 Barrels Warner - 6 1942 = 46 Barrels Pritchard 1 616 = 15 Baarels Clutts 2 356 = 8 Barrels Clutts 1 &3 681 = 16 Barrels Justus 1 1072 = 26 Barrels

1075823145 2004-02-03 Salt Water Injection Well No Violations - On site for inspection operator is pumping water from dike containment.

- injection pump not operating. - Warner # 6 2036 gal = 48 barrels - Warner # 1, 2 & 3 8572 gal. = 204 barrels - Pritchard # 1 662 gal = 16 barrels - Pritchard # 3 44gal. = 1 barrel - Clutts # 2 410 gal. = 10 barrels - Clutts # 1 & 3 726 gal. 17 barrels meter is disconnected at time of inspection. - Warner Justus # 1 1299 gal. = 31 barrels - Total barrels is 327

1081961894 2004-04-14 Salt Water Injection Well No Violations - Pump not operating while on site, pump area clean. Reading from other wells.

- Clutts 1&3 374 Gal. = 8.9 bls. Prichard 3 215 Gal. = 5.1bls -Warner Justus 1665 Gal. = 27.7 bls Warner 6 2237 Gal. = 53.3 - Clutts 2 508 Gal. = 12.1 bls Warner 1 & 3 8807 Gal. = 209.7 - Pritchard 1 784 Gal. = 18.7 bls. TOTAL = 14588 Gals. = 347 bls.

1086204712 2004-06-02 Salt Water Injection Well No Violations Operator is doing repairs to injection pump.

Reading at tanks:

  Warner #6  2377 = 56.6 barrels
  Warner # 1-2-3  8936 = 212.8
  Pritchard #3  358 = 8.5
  Pritchard # 1  875 = 20.8
  Clutts #2 561 = 13.4
  Clutts #1-3 439 = 10.5
  Warner Justus #1  1917 = 45.6
                     TOTAL 368.2 Barrels
1091715833 2004-08-05 Salt Water Injection Well No Violations Injection well couldnt open annulus valve no reading taken. Injection pump not operating while on site. Weather condition Sunny Temp. high 70s

Reading from wells -Warner #6 26.3 gal. = 0.6 barrel, Warner #1 &3 9029.4 gal. = 214.9 barrels, Warner #2 29.6 gal = 0.7 barrel, Pritchard #1 1010 gal = 24 barrels, Pritchard #3 571.2 gal = 13.5 barrels, Clutts # 2 617.7 gal = 14.6 barrels, Clutts #1 & 3 519.4 gal = 12.3 barrels, Warner Justus 1 2232 gal = 53.1 barrels Total 333.6 Average 334 barrels.

1112707817 2005-04-05 Salt Water Injection Well No Violations Check injection pressure Annulus 320 psi Injection 300 psi.

Meter reading Warner #2 584720 gal = 13921 barrels Warner #1 & 3 61855 gal. = 14727 barrels Warner # 6 87520 gal = 2083 barrels Pritchard #3 1141770 gal = 27185 barrels Clutts # 2 no meter Clutts #1 761410 gal = 18128 barrels Justus 1 3031640 gal = 72170 barrels Total 148214 barrels

1118147542 2005-06-07 Salt Water Injection Well No Violations - Joint inspection with Jeff Fry.

- Injection pump not operating, annulus and injection both 100 psi - will contact operator to have well checked.

1119551406 2005-06-23 Salt Water Injection Well No Violations - On site for inspection, pressure testing reveal tubing and annulus are the same. Met with the operator and well has been taking out service. Operator plans to remove tubing and packer to have them tested. Operator will contact when tubing is removed.
1121791123 2005-07-19 Salt Water Injection Well No Violations - Operator has well out of service, line disconnect at tank battery.

- Chief order issused 6/27/2005.

1136909786 2006-01-10 Salt Water Injection Well No Violations - Well back into operation, injection pressure 220 annulus pressure 120 ID at well.

- Water meter reading from wells- Waner #2 903650 gallons = 21515 barrels Warner 1&2 1703690 gallons = 40564 Warner #6 984450 gallons = 23439 barrels Pritchard #1 102880 gallons = 2449 barrels Pritchard #3 1789730 gallons = 42612 barrels Clutts #2 1477460 gallons = 35177 barrels Clutts 1&3 1034400 gallons = 24628 barrel Total water = 168869 barrels Weather partly sunny temp high 30s

1137569221 2020-8-27 0:00: SW No Violations 12.20
1141750413 2006-03-07 Salt Water Injection Well No Violations - ID at well injection 200 psi annulus 140 psi.

- Water meter reading from wells- Waner #2 1030860 gallons = 24544 barrels Warner 1&2 1974550 gallons = 47013 barrels Warner #6 1148190 gallons = 2733 barrels Pritchard #1 2049520 gallons = 48798 barrels Pritchard #3 257970 gallons = 6142 barrels Clutts #2 1531300 gallons = 36459 barrels Clutts 1&3 1101660 gallons = 26230 barrel Total water = barrels 185,777 Weather sunny temp high 30

1160057129 2020-8-21 0:00: SW No Violations 9.70
1163825359 2017-09-06 Salt Water Injection Well No Violations My inspection today revealed the saltwater injection well had 155 psi on the annulus and 184 psi on the injection tubing.
1168692317 2019-04-24 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
1192348066 2020-8-31 0:00: SW No Violations 3.00
1210i45737 2002-04-02 Salt Water Injection Well No Violations Well is not operating. Tank battery ID has faded and needs remarked. Dike fluids need to be kept properly emptied, to permit maximum dike capacity. Violation1501:9-3-06 (H). ID
1210i457372 2002-4-2 0:00:0 SW No Violations
1213719325 2008-06-11 Salt Water Injection Well No Violations - ID at well and tanks, Injection pump not operating while on site.

- Annulus pressure 380 injection pressure 0 - Water meter total from wells 327,241 barrels - Weather Sunny Temp 80s

1222179893 2008-09-10 Salt Water Injection Well No Violations Inspection of well and tank. Tanks have been repainted this past summer. Area around tank clean and free of debris.

- Annulus pressure 320 psi injection 0 psi injection pump not operating while on site. - Operator has constructed new building over injection pump and vault. - Water meter reading total from other well that inject into this one is 194,161 barrels.

1230036647 2008-12-23 Salt Water Injection Well Violations Noted - On site for inspection, all valve open. Injection 0 psi - on vacuum annulus 0 psi - on vacuum. Injection line at tank battery is disconnected.

- Will contact operator. - Weather - Cloudy Temp ~ 19

1233754138 2009-02-02 Salt Water Injection Well No Violations - Berry Well Service moved on site and Rigged up over well. Remove well head and release packer and let packer relax overnight.

- Chief Order issued 12/29/2008 - suspension of injection operations. Operator had taken well out of operation in November of 2008.

1233842053 2009-02-04 Salt Water Injection Well No Violations - Berry Well Service replace well head, fitting and valves. Sweeny well service pressure up on back side of tubing to 1,020 lbs. Test well annulus, test failed, try to move packer up hole but pin sheared.

- Pull tubing and packer from well.

1234376762 2009-02-09 Salt Water Injection Well No Violations - Site for injection well integrity test.

- R-4 Halliburton packer with five shear pins set at 2471.59 measurement at top of rubber on the packer. String weight 15,000 pull weight with packer set for 20,000 a total of 35,000 pounds. 5 gallons of inhibitor and fresh water pumped down back side of tubing. Pressure annulus to 1,000 psi start test, pressure leaked off at a rate of 100 psi at 10 minutes. Repressure well and retest but failed. - Release packer and remove one string of tubing (30.35) and install 3 pup joints of tubing and reset packer at 2454.30 feet. Pressure annulus to 1,000 psi , start test, loss 60 psi in 10 minutes. Repressure annulus to 800 psi and start test, failed, left gauge on well for 32 minutes and pressure dropped to 620 psi. - Pull tubing and packer from well remover packer and install bull plug on bottom, run tubing back into well and will test tubing for leak 2/10/2009. - Berry Service company service rig, Sweeny well service pressure well, Lou Martindale water truck service supply fresh water.

1248i200 2002-1-31 0:00: SW No Violations
1248i296 2002-3-18 0:00: SW No Violations
1248i30533 2001-07-05 Salt Water Injection Well No Violations FLOW METER IS IN GALLONS. WETHER 79 AND SUNNY.
1248i3053318 2001-7-5 0:00:0 SW No Violations 1.00
1248i372 2002-5-1 0:00:0 SW No Violations
1248i386 2002-5-13 0:00: SW No Violations
1248i459 2002-7-30 0:00: SW No Violations
1248i55 2001-8-17 0:00: SW No Violations
1248i96 2001-10-31 0:00 SW No Violations
1256655197 2009-10-27 Salt Water Injection Well No Violations - ID on well and tanks. Well area has safety fence around the well. Injection pressure 0 on vacuum, annulus 350.
1262720072 2010-01-05 Salt Water Injection Well No Violations - ID on well and tanks, annulus pressure 480 injection pressure 0 vacuum. Orange safety fence around well. No water meters, meters from adjacent wells have been removed because of cold weather.

- Weather condition - Temp 18 ground cover with snow.

1269267351 2010-03-17 Salt Water Injection Well No Violations - Operator has injection well in operation, Met with Joe Melville. Annulus pressure 240 injection pressure 0. Joe Melville plans to have all of his injection wells annulus treated and pressure up on Friday 3/19/2010.

- Weather condition Sunny Temp 60s

1291670392 2010-12-06 Salt Water Injection Well No Violations - ID on well and tanks, Well annulus pressure 0 injection pressure 300

- Injection pump operating. - water meter reading 420006 gallons = 1,000 barrels Weather temp 10 windy frozen ground

1300952776 2020-8-20 0:00: SW No Violations 8.10
1320675529 2007-09-11 Salt Water Injection Well No Violations - Injection pump operating while on site. ID at well. Annulus pressure 440 psi injection 360 psi.
1323783249 2011-11-03 Salt Water Injection Well No Violations - Well annulus pressure leaking off. Release packer and pull 2 3/8 tubing. The 8 inch casing rusted through at ground level. The 4 1/2 inch casing rusted at compression slip. The operator will repair casing.
1323799997 2011-11-07 Salt Water Injection Well No Violations - The operator has cut about 8 inches from each casing and replace with weld on collars and installed new well head.
1328633314 2012-02-07 Salt Water Injection Well No Violations - Annulus pressure 520 psi, Injection pressure 0 on vacuum. UD at well and tanks. Injection line disconnect at tank area.

- Dike area free of water. - Weather Overcast Temp. low 30s

1344868902 2012-08-08 Salt Water Injection Well No Violations - inspection of well, ID on well and tank. Annulus pressure 500 injection pressure 0 on vacuum.
1358432491 2013-01-17 Salt Water Injection Well No Violations - ID on Well and tank, Dike area free of water and debris.

- Annulus pressure 200 Injection pressure 0 - Unloading pad clean and free of debris. - Weather condition - cloudy temp 30s

1364390569 2013-03-27 Salt Water Injection Well No Violations - On site for inspection, ID at well. Annulus pressure 440 Injection pressure 0.

- Unloading pad clean of debris. Connection pipe lines at unloading pad closed and pad locks installed to prevent unauthorized use. - Weather condition Cloudy Temp 30s

1368033092 2013-05-08 Salt Water Injection Well No Violations - Annulus pressure 560 Injection 0 .

- ID on well and tank, unloading pad free of water and debris, pad locks on unloading pipe line valves. - Weather condition; partly sunny Temp. 70s, wet ground conditions.

1372849637 2013-07-03 Salt Water Injection Well No Violations - Annulus pressure 530 Injection 300 . Injection pump operating while doing inspection.

- ID on well and tank, unloading pad free of water and debris, pad locks on unloading pipe line valves. - Weather condition; Cloudy Temp. 70s, wet ground conditions.

1382548397 2013-10-23 Salt Water Injection Well No Violations - ID on well and tank, 5 / 210 berral tanks in the dike area. Unloading pad clean and free of debris. Annuls pressure 200 injection pressure 0
138592899 2014-6-3 0:00:0 SW No Violations
1393512547 2014-02-27 Salt Water Injection Well No Violations - Unable to access well due to flooding condition at well area.

- ID on tank and Dike area has some frozen water in it, five 210 barral tanks in dike. - Unloading pad free of debris. - Weather condition partly cloudy temp 22 ground condition frozen.

1411473642 2014-09-23 Salt Water Injection Well No Violations - Inspection of UIC well, ID on well and Tank

- Annulus pressure 340 PSI Injection pressure 0 PSI - Water meter 58618 barrels - Dike area free of debris unloading pad freeof debris -

1429386347 2019-02-21 Salt Water Injection Well No Violations Inspected the containment dike, tanks, unload pad, injection pump. Identification is posted. The access road to the well is flooded. Unable to access the well and to get injection and annulus pressures. The containment dike is free of fluids.
1453823620 2016-01-25 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well and facility.
1461686563 2016-04-20 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Containment dike is free of fluids. Identification posted at the well and facility.
1482823611 2009-02-20 Salt Water Injection Well No Violations - Set Halliburton R-4 packer in tension with 15,000 lbs string weight 20,000 pull weight total of 35,000 Lbs. Sweeny Service Co. pressure annulus to 1,000 psi. Test held pressure for 20 minutes with no loss. Bleed pressure down to 460 Psi on the annulus. Total length of 2 3/8 tubing 2469.74 packer set at 2467.60 measure at top of rubber.

- On site for test was Berry Service Rig 2 crew, OEA - Joe Melville, Seal Tite - Matt Werner and Sweeny Well service. - Weather Condition Temperature 22 wind chill 10 Humidity 68% Barometer 30.09

149250296 2009-2-10 0:00: SW No Violations
1503669102 2006-06-07 Salt Water Injection Well No Violations - Well has ID posted.

- Annulus pressure 280 injection pressure 0 Well receive water from Warner 0091 meter 1235250 gallons = 29,410 barrels, Warner 0096 2427180 gallons = 57,790 barrels, Warner 0186 1409830 gallons = 33,567 barrels, Pritchard 0199 2497190 gallons = 59,456 barrels, Pritchard 0092 401080 gallons = 9,549 barrels

1518916342 2003-10-21 Salt Water Injection Well No Violations 1- at well operator injection gauge reading 280 psi. ODNR gauge 320psi. injection pump operating while taking reading. Annulus reading operator gauge 180psi ODNR gauge 200psi.

2- Water reading are taken at each tank.

 Clutts 1 & 3         635 gal  =   15.1 barrels
 Clutts 2               356 gal  =     8.5 barrels
 Justus 1              861 gal  =   20.5 barrels
 Pritchard 1          534 gal  =   12.7 barrels
 Warner 1 & 3     8325 gal =  198.2 barrels
 Warner 2           Meter removed
 Warner 6            1832 gal  =  43.6 barrels
  TOTAL             12543 gallons    298.6 Barrels
1544812132 2018-12-13 Surface Facility Construction No Violations New sump pump has been installed and is functioning. Pumping containment fluid into tank for disposal.
1555329845 2017-12-13 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 22 psi on the annulus and 41 psi on the injection tubing. The containment dike was free of fluids. Legible identification was
1578393005 2020-2-10 0:00: AM No Violations
1597413676 2020-8-13 0:00: SW No Violations 1.00
1598963011 2020-8-19 0:00: SW No Violations 8.20
1673994397 2012-06-14 Salt Water Injection Well No Violations - ID on well and tank. Orange plastic safety fence around well.

- Annulus pressure 520 PSI injection pressure 0 on vacuum

1679681392 2017-06-02 Salt Water Injection Well No Violations Salt water injection well inspection. The injection pressure was 6 PSI, the annulus pressure was 241 PSI. No violations noted.
1699238845 2016-11-21 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pressure, annulus pressure and unloading pad. Identification posted at the well and facility.
1713624721 2015-04-28 Salt Water Injection Well No Violations UIC inspection. The annulus pressure was 400 PSI, the injection side was on vacuum.
1790741231 2018-05-30 Salt Water Injection Well No Violations Inspected the unloading pad, containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted at the well and facility.
1804257483 2002-10-16 Salt Water Injection Well No Violations Inspection revealed no violations noted this date. Well is in operation. OWNER NEEDS TO REMOVE FLUIDS FROM DIKE AT THE STORAGE TANKS.
1818283945 2016-03-07 Salt Water Injection Well No Violations UIC inspection. The annulus pressure was 146 PSI. The injection pressure was 51 PSI.
1836916794 2011-11-08 Salt Water Injection Well No Violations - New Halliburton R-4 packer with 5 shear pins installed (1 removed). 2 3/8 lined tubing placed back into well.
1867811912 2012-07-25 Salt Water Injection Well No Violations Good identification. Tank battery free of water. Tank battery was inspected due to close proximity to another injection well. Lack of time prevented the inspection of the well pressures.
1904143232 2011-03-23 Salt Water Injection Well No Violations - Annulus pressure 220 injection pressure 0 ID on well and tanks.

- Dike area free of water and debris

1935557037 2005-10-04 Salt Water Injection Well No Violations - Well is still out of service, water line disconnected.
2092176865 2019-03-18 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids.
2095096269 2009-02-06 Salt Water Injection Well No Violations - On site to witness tubing string place into well. 18 joints of tubing installed into well 2/4/2009, operator had new internal coupler overnight freight so job could be completed today. Packer wasnt set will set Monday 2/9/2009.
2119865123 2009-06-10 Salt Water Injection Well No Violations - Annulus pressure 460 injection pressure 0 (vacuum) ID on well and tanks. Operator has installed an orange safety fence around well. Injection pump not operating while on site. Pump vault has a small amount of fluid in it. Unloading pad clean and free of debris.
2138918132 2007-04-11 Salt Water Injection Well No Violations - Inspection of well, ID posted at well. Injection reading 0 (vacuum) annulus 260 PSI

- Weather overcast light rain Temp. high 30s Water meter reading from Warner 96 3023840 gallons = 71996 barrels. Clutts 119 1930420 gal. = 45962 Barrels, Warner 186 2219230 gal. = 52838 barrels, Pritchard 199 & 92 780430 gal. = 18581 barrels, Clutts 1 & 3 154810 gal. = 3685 barrels, total barrels of water 910,496 barrels.

2146426590 2011-06-29 Salt Water Injection Well No Violations - ID at well and tanks, Unloading pad free of debris, Annulus pressure 420 Injection pressure 300 injection pump operating while on site.
2146575421 2009-03-31 Salt Water Injection Well No Violations - ID on well and tanks. Well injection 0 psi, annulus 320 psi.

- One of the tank at the unloading pad area had been repaired and operator is in the processes of cleaning dike area of a small amount of crude oil.

245842169 2006-10-26 0:00 SW No Violations
323180766 2018-12-5 0:00: SW No Violations 2.40
341562683 2009-2-5 0:00:0 SW No Violations
343669874 2011-4-21 0:00: SW No Violations
376620595 2011-11-9 0:00: SW No Violations
425825194 2007-6-7 0:00:0 SW No Violations
491223378 2009-6-10 0:00: SW No Violations
518364039 2003-7-2 0:00:0 SW No Violations
537112671 2008-1-16 0:00: SW No Violations
603871188 2009-2-19 0:00: SW No Violations
623076312 2009-2-3 0:00:0 SW No Violations
632378703 2018-12-4 0:00: SC No Violations 0.50
683386190 2004-10-5 0:00: PL No Violations
834681306 2020-5-27 0:00: SW No Violations 1.00
906901750 2011-10-6 0:00: SW No Violations
920375530 2016-7-27 0:00: SW No Violations 1.00
UIC1742 1998-11-13 0:00 SW No Violations
UIC1743 1998-11-13 0:00 SW No Violations
UIC1745 1998-12-22 0:00 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
001248i372 US-OH-106660 2002-05-01 Permit not displayed
0447367402 US-OH-124845 2015-12-04 Pits not liquid tight/Improper construction or use
1230036647 US-OH-106187 2009-02-20 Failure to pass required test

For data sources see[5]

References