| Well ID: 34-129-20228 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.61,"lon":-82.95,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Pickaway | |
| Municipality: Circleville Township | |
| Operator Name: OHIO ENERGY ASSETS, INC. | |
| Well Pad ID: | |
| Farm/Lease Name: JOCOBRY UNIT | |
| License Status: Final Restoration | |
| License Date: 2009-07-13 | |
| Spud Date: 2009-08-26 | |
| Spud Drilling Contractor: BOWMAN DRILLING | |
| Final Drill Date: 2009-09-08 | |
| Well Total Depth: 2815.00 ft | |
| Configuration: Directional | |
| Latitude: 39.610000 | |
| Longitude: -82.950000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2009-07-13 | Proposed Formations:TRENTON/ROSE RUN, Issued Date:7/13/2009, Expired Date:7/13/2010 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
| Reached Total Depth | 2009-09-08 | |
| Plugged/Abandoned | 2009-09-21 | |
| Completion Report Received | 2009-10-09 | |
| Construction Permit Expires | 2010-07-13 | |
| Record Last Modified | 2013-03-14 |
For data sources see[2]
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1713362855 | 2009-8-25 0:00: | DD | No Violations | |
| -1981346394 | 2009-8-27 0:00: | DD | No Violations | |
| -889351 | 2009-9-10 0:00: | DD | No Violations | |
| 0000889351 | 2009-09-10 | Drill / Deepen / Reopen | No Violations | - Drilling progress, well drilling completed on 9/8/2009 dry hole.
- Air pit closed, fluid pit will remain open until well is plug. Safety fence still around drilling location and safety fence around fluid pit. One fresh water tank still on location inside of safety fence. |
| 0395057368 | 2009-09-08 | Drill / Deepen / Reopen | No Violations | - Drilling progress, well depth at 2753 while on location, doesnt look favorable for a production well. |
| 1254146451 | 2009-08-31 | Drill / Deepen / Reopen | No Violations | - On location for drilling progress.
- Operator is setting up to install directional drilling tools into well bore. All the directional tools not on location wait for them to be deliver. Logging truck also on location. Witness testing of directional drilling hammer before installed into well. |
| 1254155728 | 2009-09-21 | Plug / Plug Back | No Violations | - On site for plugging well. Berry Well Service doing the work Formation Cementing cement contactor.
- 2 3/8 inch run into well bore for plugging. Plugs set at Rose Run, Trenton, bottom of surface casing and surface. Casing cut below grade and ID place over well and covered with subsoil and graded. |
| 1398326300 | 2010-05-20 | Final Restoration | No Violations | Final Restoration, well permitted 7/13/2009 well plugged and abandon 9/21/2009.
- Area has been graded and vegetation has started to establish. |
| 1713362855 | 2009-08-25 | Drill / Deepen / Reopen | No Violations | - Drill and equipment on site fluid and air pit dug. Safety fence around location, silt fence along Island Road. Signage posted at entrance. Drilling started today. |
| 1981346394 | 2009-08-27 | Drill / Deepen / Reopen | No Violations | - On location for drilling progress, 17.5 inch diameter hole to 190 feet. Will try to set conductor later in the day. |
| 2137033263 | 2009-08-29 | Drill / Deepen / Reopen | No Violations | - Surface casing -
- Conductor was set on 8/28 to 190 feet. 11.75 inch conductor used. - 11 inch hole drilled for 8.625 inch surface casing, used casing, Casing had threads damage, damage was done with power tong when pipe was remover from another well. - total of 810 feet of casing placed into well plus landing joint. Good circulation, cement circulated to surface, rubber wiper plug used. 200 sacks of cement plus CaCl. |
| 395057368 | 2009-9-8 0:00:0 | DD | No Violations |