Well Details

Well ID: 34-129-20251
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Wayne Township
Operator Name: CHUCK HENRY ENERGY LLC
Well Pad ID:
Farm/Lease Name: GIFFORD C & B (SWIW #10)
License Status: Active Injection
License Date: 2015-09-23
Spud Date: 2015-01-02
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2015-01-12
Well Total Depth: 3815.00 ft
Configuration: Vertical
Latitude: 39.600000
Longitude: -83.030000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-12-31 Proposed Formations:BLACK RIVER, TREMPEALEAU, ROME, Issued Date:12/31/2014, Expired Date:12/30/2016 12:00:00 PM, Drilling unit acres:163.909, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2015-01-12 BASED ON CHIEF'S ORDER 2016-203 AUTHORIZATION TO INJECT AS OF 5/25/2016. CHANGE STATUS TO AI ON 7/5/2016
Completion Report Received 2015-04-20 BASED ON CHIEF'S ORDER 2016-203 AUTHORIZATION TO INJECT AS OF 5/25/2016. CHANGE STATUS TO AI ON 7/5/2016
APP 2015-09-23 Proposed Formations:KNOX TO MT SIMON, Issued Date:9/23/2015, Expired Date:9/22/2017 12:00:00 PM, Drilling unit acres:163.909, Proposed Well Type:SWD, Proposed Well Class:SWIW
Last Compliance Report 2016-02-04 BASED ON CHIEF'S ORDER 2016-203 AUTHORIZATION TO INJECT AS OF 5/25/2016. CHANGE STATUS TO AI ON 7/5/2016
Change of Owner 2017-06-28 Operator changed from 5755, HOCKING HILLS ENERGY WELL SERV to 9919, CHUCK HENRY ENERGY LLC
Record Last Modified 2017-06-28 BASED ON CHIEF'S ORDER 2016-203 AUTHORIZATION TO INJECT AS OF 5/25/2016. CHANGE STATUS TO AI ON 7/5/2016
Construction Permit Expires 2017-09-22 BASED ON CHIEF'S ORDER 2016-203 AUTHORIZATION TO INJECT AS OF 5/25/2016. CHANGE STATUS TO AI ON 7/5/2016

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1027659682 2020-7-27 0:00: SW No Violations 2.00
-1053754982 2019-2-11 0:00: SW No Violations
-1126073824 2016-11-30 0:00 SW No Violations 2.50
-1193693489 2017-7-26 0:00: SW No Violations 2.70
-1260963192 2018-10-17 0:00 SW No Violations
-1288246677 2016-1-25 0:00: PW No Violations 3.50
-1380221034 2016-4-20 0:00: PW No Violations 3.00
-1394440620 2016-1-5 0:00:0 PB No Violations 8.00
-1397167303 2016-3-17 0:00: SC No Violations 5.50
-1411905854 2017-1-26 0:00: SW No Violations 3.00
-1457571713 2016-8-30 0:00: SW No Violations 2.50
-1628947817 2016-5-9 0:00:0 PL No Violations 1.00
-1680537534 2015-1-8 0:00:0 DD No Violations 0.60
-1694279984 2016-1-26 0:00: PW No Violations 10.00
-1745286350 2017-9-6 0:00:0 SW No Violations
-1749574341 2019-3-13 0:00: SW No Violations
-1833773600 2016-1-14 0:00: PW No Violations 4.50
-1929070593 2016-6-20 0:00: SW No Violations 5.50
-1946943445 2016-4-1 0:00:0 PW No Violations 1.00
-2062427552 2017-8-2 0:00:0 SW No Violations 4.00
-213407752 2016-11-15 0:00 SW No Violations 1.00
-217416453 2016-11-29 0:00 SW No Violations 8.00
-250179834 2016-3-18 0:00: SC No Violations 7.50
-328088757 2018-9-20 0:00: SW No Violations 2.00
-441549210 2015-10-14 0:00 PW No Violations 2.00
-460674828 2015-1-3 0:00:0 CS No Violations 4.00
-498767420 2016-3-24 0:00: SW No Violations 3.00
-645851963 2016-1-6 0:00:0 PB No Violations 9.00
-81838465 2016-11-22 0:00 SW No Violations 0.50
-965211182 2018-5-30 0:00: SW No Violations 2.00
0081838465 2016-11-22 Salt Water Injection Well No Violations Compliance Notice # 213407752 follow up inspection. The injection tubing master valve is closed. Annulus is on vacuum. A service rig has been scheduled for 11-23-16.
0150249310 2017-12-13 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 452 psi on the annulus and the injection tubing was on vacuum. The containment dike was free of fluids. Legible identification was posted.
0213407752 2016-11-15 Salt Water Injection Well Violations Noted Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The annulus was on a strong vacuum. I called Shawn Maynard and told him the well has mechanical failure and they need to shut in the well and test the annulus. I also talked to Doug Kitchen who said that they are going to schedule a service rig.
0217416453 2016-11-29 Salt Water Injection Well No Violations Witnessed repairs to injection line connections with in the containment dike area, flanged gaskets and 1/4 inch fittings that were corroded. Larry Howdyshell and Shawn Maynard on site. Collected a brine sample from the filter skid drain. Sample to be taken to the ODNR Lab. Inspected the injection and annulus pressure. The containment dike is free of fluids.
0250179834 2016-03-18 Surface Facility Construction No Violations Containment dike walls were assembled. A 4 layer of sand was applied to the inside of the containment prior the liner installation. The 30 mil liner was installed and small diameter washed gravel was placed on top of the liner. Gravel is approximately 4 to 5 thick. 30 tons of sand and 15 tons of washed gravel were used on the containment construction.
0328088757 2018-09-20 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted at the well and facility. The containment dike is free of fluids. The two pen recorder chart is past due for changing the data is being wrote over. I contacted Larry Howdyshell and told him to change the chart.
0399489207 2016-04-12 Surface Facility Construction No Violations Injection line test. Test at 605 psi. at 5 minutes 602psi, at 15 minutes 598 psi. Company was unable to demonstrate a successful test on the 4 gathering line flowing to the surface facility from the production tanks.
0441549210 2015-10-14 Production Wells No Violations Permit to convert to SWIW. Kilbarger service rig is on location. Rig is not set up on the well. Access road has a gravel stream crossing that doesnt have a culvert installed. The water is backing upstream of the crossing. Proposed location for the surface facility has been disked up recently.
0451637177 2018-08-29 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted at the facility and the well. The containment dike is free of fluids.
0460674828 2015-01-03 Casing String Witnessed No Violations -

- Spud date 1/2/2015, - - Good circulation when pumping cement, cement return to surface. 145 sacks of class A cement used.

0498767420 2016-03-24 Salt Water Injection Well No Violations Hocking Hills Energy has placed the 2 injection tubing inside the 4 seamless conduit. The are waiting on the manufacture of the injection tubing to apply factory ends on the tubing before making any connections.
0645851963 2016-01-06 Plug / Plug Back No Violations Rig tools tagged top of cement plug at 3424. Service rig installed 2387.60 of 4.5 casing with a packer. Pumped 50 sacks cement through packer ports. Tested the 4.5 casing at 950 psi for 5 minutes with no loss in pressure. Well is shut in with a swedge and a valve.
0765945029 2016-11-23 Salt Water Injection Well No Violations Compliance Notice # 213407752 follow up inspection. Berry Well Service rig on the well. Released the packer and extracted the injection tubing. The injection tubing had a hole at approximately 2036. The tubing and packer job is scheduled for 11-28-16.
0913363599 2017-06-01 Salt Water Injection Well No Violations Salt water injection well inspection. The injection pressure was 0 PSI, the annulus pressure was 520 PSI. No violations noted.
0953064122 2017-07-13 Salt Water Injection Well No Violations Quarterly UIC inspection. The annulus pressure was 225 PSI, the injection tubing was on vacuum. Legible identification was posted. No violations noted.
0959113957 2015-01-05 Casing String Witnessed No Violations -

- - 80 sacks of class A cement used. - Did not witness cement job. - inspection late afternoon and operator has Formation Cementing on site to fill annulus of casing, trying to place tubing in the annulus for placement of cement. Off-site due to time.

0965211182 2018-05-30 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The containment dike is free of fluids. Identification is posted at the facility and the well.
1008922650 2015-05-05 Production Wells No Violations Site Evaluation for a salt water injection well permit. Access road crosses Lick Run. The crossing has been built up with stone. The crossing is 612 feet South West of the well at GPS N39.60084 / W083.03631. There are 9 water wells with-in the 1/2 mile area of review. Water well Log Numbers: 20829, 833949,781836,983767, 69685,69684,757146, 971276, 831168. The well is located 993 feet North West of the Access road entrance (GPS N39.60031/W083.03759). The Gilford C&B#3 # 251 is located in a flat agricultural field. The well is not equipped with production lines or equipment. The well is shut in with two valves and a plug.
1053754982 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 1st, 2nd, 3rd, & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
1126073824 2016-11-30 Salt Water Injection Well No Violations Witnessed the start up of injection operations. All surface connections are water tight. The containment dike is free of fluids. Shawn Maynard and Doug Kitchen on site.
1193693489 2017-07-26 Salt Water Injection Well No Violations I met with well owner Chuck Henry Energy. The purpose of the meeting was to ensure the well is in compliance with the permit conditions. The well was being operated by Hocking Hills Energy. Hocking Hills Energy monitoring systems have been disable. Chuck Henry Energy is now the operator of this well. They have decided to eliminate the system Hocking Hills Energy had installed and replace with conventional float switches, Murphy gauge and any other component of the monitoring equipment. This change is to simplify the system with less chance of failure.
1222392147 2016-02-04 Production Wells No Violations Permit to convert to salt water injection well. Install new DL Shear tension packer (DL-412-4500-087) and 2336 feet of used 2 3/8 tubing. Pulled 14,000 lbs. over string weight. Fill annulus with 24.52 barrels fresh water and inhibitor. Unable to pressure up the annulus above 450 psi. (Test pressure is 545psi) Multiple attempts to tighten the wellhead were not successful. The annulus test was canceled and a new wellhead has been ordered.
1232364877 2019-04-29 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019.
1260963192 2018-10-17 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 8 psi on the annulus and the tubing was on vacuum. The containment dike was fee of fluids and the well had legible identification. Chuck Henry Energy had a representative on site during my inspection repairing one of the needle valves at the wellhead.
1288246677 2016-01-25 Production Wells No Violations Permit to convert to salt water injection well. Formation packer on the bottom of the 4.5 casing was drilled out on 1-22-16. Currently cleaning out the open portion of the well below the 4.5 casing at 2861. Circulating shale cuttings and gel to surface. Drilling with a 3 7/8 bit.
1380221034 2016-04-20 Production Wells No Violations Permit to convert to salt water injection well. Preparing for the pressure fall off test. A slick line truck is on the well installing down hole gauges. Fluid level is at 290 feet. Tested injection line due to the removal of the master valve and the installation of a frac valve. Injection line was tested at 420 psi due to the pressure pop off valve on the injection pump. Held 420 psi for 15 minutes with no loss.
1394440620 2016-01-05 Plug / Plug Back No Violations Permit to convert to SWIW plug back. Pumped 80 sack plug through 3820 of 2 3/8 tubing. Plug from 3830 to 3400 .
1397167303 2016-03-17 Surface Facility Construction No Violations Constructing the containment dike walls. Approved plan calls for 32 by 32 by 4 containment with two 300 barrel tanks and one 100 barrel tank. The containment as built is 38 7.5 by 29 2.75 by 35 with two 300 barrel tanks and one 210 barrel tank. I told Shawn Maynard that they need to submit the revised plan to the UIC section for approval, prior to proceeding with construction.
1411905854 2017-01-26 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids.
1421172639 2014-12-30 Not Drilled No Violations - On site to review propose well location, operator is cutting in lease road and small stream crossing.

- The operator has applied for drilling permits, none have been issued as of this date.

1452109439 2016-01-04 Plug / Plug Back No Violations Permit to convert to SWIW. Plug back. Kilbarger service rig is running 2 3/8 tubing for the plug back.
1452696752 2016-01-11 Production Wells No Violations Permit to convert to salt water injection well. Appalachian Well Survey wire line truck ran a cement bond log on the 4.5 casing.
1454417937 2016-02-01 Production Wells No Violations Permit to convert to saltwater injection well. Baker Hughes and Producers service company on site to run a spinner survey. Accompanied by UIC Geologist. Two 500 barrel tanks are on site and filled with brine for the survey.
1456879632 2016-03-01 Production Wells Violations Noted An inspection of the well site revealed Brine and Oil contamination on the ground. The total area is approximately 72 feet by 33 feet. High Range Quantabs were used at 5 locations along the boundary of the contamination. Three of the Quantabs were maxed out at above 6215 ppm Cl. The remaining Quantabs were 4429 ppm Cl and 3993 ppm Cl. Residual products that were contained in the lined pit are now on the ground, such as gel, lost circulation material, oil and brine. All contaminated soil and water must be removed from the location. The brine must be disposed of at a class 2 disposal well. The contaminated soil must go to an EPA approved land fill. A detailed remediation plan must be submitted to the UIC Section for approval prior to remediation of the site.
1457446345 2016-03-07 Production Wells No Violations Compliance notice # 1456879632 follow up inspection. Meet with Shawn Maynard on site to review the progress of the ongoing remediation. High Range Quantabs were used to delineate remaining areas of contamination.
1457571713 2016-08-30 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted on the facility and the well. The containment dike was free of fluids.
1458156062 2016-03-16 Salt Water Injection Well No Violations Secondary containment inspection. Hocking Hills Energy has began installing the secondary containment for the 2-210 barrel tanks. Approx. half of the posts have been driven and the walls have been attached. Once the walls are complete. The walls will be backfilled prior to the sand layer being installed. After the sand layer is installed the liner will be installed. Picture were taken of the wall construction.
1458755366 2016-03-23 Salt Water Injection Well No Violations Hocking Hills Energy is on digging a trench from the containment dike to the well head. The trench is approx. 3 deep and 1.5 wide. 4 black seamless pipe was placed in the trench along with 1.25 jointed conduit. The trench was backfilled and the injection line will be installed inside the 4 pipe at a later date.
1459533074 2016-04-01 Surface Facility Construction No Violations Two 300 barrel fiberglass tanks and one 210 barrel steel tank have been set in the containment dike. A filter skid and injection pump are also in the containment dike. The 2 injection line has been installed in a 4 plastic line from the well to the out side of the containment dike.
1461070332 2016-04-15 Surface Facility Construction No Violations Test the brine transfer line from the Lutz Delong tank battery GPS N39.61133/W083.04930 to the Gifford surface facility. Tested at 202 psi for 15 minutes with a loss of 2psi.
1461251471 2016-04-21 Salt Water Injection Well No Violations I witnessed the pressure fall off test. The test began at 0600 hours. The pressure was 0 for the duration of the test. The well is on vacuum. The test lasted for 12 hours.
1461338825 2016-04-20 Production Wells No Violations Compliance Notice # 1456879632 Follow up inspection. Contaminated material has been removed from location. Site has been rough graded and seed and mulch are being applied to bare areas. The access road has had a Geo fabric liner and gravel applied from the paved county road to the surface facility.
1462218385 2016-05-02 Production Wells No Violations Permit to convert to salt water injection well. Injection line test. Tested the injection line from the facility to the wellhead master valve at 570 psi, at five minutes 565psi, at fifteen minutes 560 psi. Test passed. Continuous monitoring sensors for the injection line and annulus have not been installed. The injection line leak sensor has not been installed. The well is not equipped with 1/4 fittings on the annulus or injection tubing. I talked to Shawn Maynard about the items that need to be installed prior to requesting the Chief Order to inject.
1463145005 2016-05-10 Surface Facility Construction No Violations Inspected the containment dike, tanks, injection pump, injection pressure sensor installation, annulus pressure sensor installation, Pressure cut off switch (Murphy Switch), Flow meter (currently reading 327 barrels) I asked Shawn Maynard why they have injected 327 barrels. Shawn stated that it was during testing of the facility sensors and tank level sensors. I told him that they do not have authorization to inject. All valves from the facility to the well are open including the injection tubing master valve. The injection line leak sensor is connected to the 4 plastic conduit. The sensor is not vented to the tank as described in the submitted plans. The rubber transition fitting from the 4 plastic conduit to the 2 injection line is not installed on the facility side. It is also not connected on the well side. The injection pressure sensor has been installed at the facility on the injection line between the pump and the flow meter. Identification was not posted at the well or facility. 1/4 injection fitting and 1/4 annulus fitting has been installed.
1466428107 2016-06-16 Surface Facility Construction No Violations Permit to convert to salt water injection well issued 9-23-2015. Inspected the facility, containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. The tanks are full of brine. All valves are open(including the injection tubing master valve and the injection line valves). The electric service is connected and all switches are on. New filter socks are on top of the filter housing. The flow meter read out is contained in a locked metal cabinet at the facility. I was not able to access the flow meter display. The containment dike is free of fluids. Identification is posted at the facility and the well. The injection line leak sensor is not bolted to the housing. The leak sensor housing is also not vented to the tank. The leak sensor housing is vented into the containment dike.
1467381388 2016-06-29 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well and facility. The flow meter is not connected to a visual display.
1469798748 2016-07-28 Salt Water Injection Well No Violations Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification posted at the well and facility. The onsite digital display for volume and pressure was not operational during the inspection. The containment dike was free of fluids.
1480685346 2016-11-28 Salt Water Injection Well No Violations Compliance Notice # 213407752 follow up inspection. Berry Well Service rig installed a rebuilt DL shear Tension Packer DL412-4500-087, with new 2 3/8 inch tubing set at 2328.65 feet. After setting the packer, 150 gallons of fresh water was placed in the annulus with corrosion inhibitor. The annulus fluid level was at the surface. The annulus was pressure tested at 620 psi for 15 minutes with no loss in pressure.
150249310 2017-12-13 0:00 SW No Violations 0.10
1502799603 2017-08-15 Salt Water Injection Well No Violations My inspection today reveled the well is in compliance. The two pin recorder has been installed and is working. No violations noted. I did not check the annulus or tubing pressure this inspection.
1518736152 2016-03-17 Production Wells No Violations Compliance Notice # 1456879632 follow up inspection. Tested standing water with high end Quantabs. Results ranged from 2521 ppm Cl to 486 ppm Cl. Reviewed the results with Shawn Maynard on site.
1527564798 2019-04-29 Salt Water Injection Well No Violations My inspection of this well revealed the well was on vacuum and the annulus had 8 psi. The dike was relativity free of fluids. Legible identification was posted.
1599664728 2015-10-29 Production Wells No Violations Production well inspection. Kilbarger Drilling has a service rig on site. No work today. The well has been permitted to become a injection well.
1628947817 2016-05-09 Preliminary Restoration No Violations The purpose of this inspection is a status check on a preliminary restoration. During my inspection I witnessed the salt water injection well is equipped with 4.5 inch casing and tubing. The Injection equipment consists of two 300 bbl. fiberglass tanks, one 210 bbl. steel tank, a filtration system, and a 400 RPM 33 GPM reciprocation pump all within a steel dike with 30 mil liner and gravel. The lease road has gravel on top of a woven fabric liner. The site has vegetation growing up through the straw mulch. Location has met 1509.072 A requirements and preliminary restoration has passed.
1670037329 2015-07-14 Production Wells No Violations Permit application to convert to salt water injection well. I measured the access road from Smith Haus road to the stream crossing it was 440.
1680537534 2015-01-08 Drill / Deepen / Reopen No Violations - On site for drilling progress, drilling depth 2,392 well permited to 3500
1694279984 2016-01-26 Production Wells No Violations Permit to convert to salt water injection well. Drilled out (cleanout) open portion of well with a 3 7/8 bit to 3391. Circulate well capacity to surface, flow into a plastic lined pit. Disconnect power swivel and mud pump. Start extracting tubing.
1737859529 2017-11-28 Work Over Reconditioning No Violations Berry Well Service reworked the well. The tubing and packer were tripped out of the hole on November 27, 2017. The tubing was in poor condition and was replaced. Used pressure tested and drifted 2 3/8 inch, 4.70 pound per foot, 8 round thread, EUE (upset), L80 and J55 lined pipe was utilized. The D L Shear Tension Packer DL412-4500-087 was rebuilt and utilized. On November 28, 2017 a total of 72 joints of pipe were run in the hole with a tally of 2315.15 feet in length, the packer at 2.85 feet and set at 2318.00 feet with a pup joint that was 3.45 feet. Inhibitor was mixed with 55 barrels of water in the Martindill Oilfield Service LLC truck UIC 25-344. Cemenco Services pumped the water through the tubing and circulated to the surface. The packer was set, well head completed, and pressure tested. The well lost less than one percent of the original pressure after 15 minutes. The well passed and was put back into service.
1745286350 2017-09-06 Salt Water Injection Well No Violations My inspection today revealed the saltwater injection well had 129 psi on the annulus. The injection tubing was on vacuum.
1833773600 2016-01-14 Production Wells No Violations Permit the convert to salt water injection well. Currently running tubing and drill bit into the 4.5 casing to drill out the packer at the bottom of the 4.5 casing. Packer set at 2387.60.
1841363082 2016-11-21 Salt Water Injection Well No Violations Compliance Notice # 213407752 follow up inspection. The injection tubing master valve is closed. Annulus is on vacuum.
1929070593 2016-06-20 Salt Water Injection Well No Violations I was asked by UIC inspector Jon Scott to witness the start up of this injection well. Per Chiefs order 2016-203, this allows the operator to begin injecting salt water. The flow meter before injecting today read 2979 barrels. During my inspection, the operator put down 8 barrels of salt water. The injection side measured 0 PSI. The annulus pressure was 168 PSI. I did not observe any leaks during the operation of the well.
1946943445 2016-04-01 Production Wells No Violations Compliance notice # 1456879632 follow up. Standing water at the well site was tested with high range Quantabs, The results ranged from 2284 ppm cl to 403 ppm cl.
2039418780 2016-03-11 Production Wells No Violations Compliance Notice # 1456879632 follow up inspection. Field tested standing water with High Range Quantabs on the previously delineated contamination area. (1) 486 ppm Cl (2)693 ppm Cl (3) 693 ppm Cl (4) 1037 ppm Cl (5) 2521 ppm Cl (6)533 ppm Cl (7) 753 ppm Cl (8) 486 ppm Cl. Meet with Shawn Maynard on site to review continued remediation.
2051237981 2018-03-15 Salt Water Injection Well No Violations My inspection revealed the salt water injection well was on vacuum on the tubing and had 20 psi on the annulus. The dike was free of fluids. Legible identification was posted.
2062427552 2017-08-02 Salt Water Injection Well No Violations The purpose of my inspection was to determine if the system that was installed to monitor the annulus and injection line and tank levels was working correctly. The sonic tank level detection system has been replaced with float switches and a murphy switch, The murphy switch is set at 300 PSI. Only two tanks are being used. The two 300 barrel fiberglass tanks are being used. The 210 barrel steel tank has been taken out of service due to the corrosion of the steel tank. The fiberglass tank that is being used to hold salt water to be pumped down the injection well is protected by a float switch. The second fiberglass tank is a over flow tank and will be protected by a float switch that will shut down the electronic valve on the production line. The two pin recorder will be installed by 8-4-2017.
2087691996 2020-5-26 0:00: SW No Violations 1.00
399489207 2016-4-12 0:00: SC No Violations 3.00
451637177 2018-8-29 0:00: SW No Violations 0.70
765945029 2016-11-23 0:00 SW No Violations 8.50
913363599 2017-6-1 0:00:0 SW No Violations 2.50
953064122 2017-7-13 0:00: SW No Violations 0.40
959113957 2015-1-5 0:00:0 CS No Violations 3.30

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0213407752 US-OH-121880 2016-12-22 Mechanical failure/contamination
1053754982 US-OH-100935 2019-04-08 Failure to report disposal fees
1232364877 US-OH-106247 2019-05-09 Failure to file salt water injection annual report
1456879632 US-OH-113236 2016-05-06 Well operation causing pollution and contamination

For data sources see[3]