Well Details

Well ID: 34-129-20258
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Pickaway Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: BJM CO INC
License Status: Producing
License Date: 2015-06-12
Spud Date: 2015-06-16
Spud Drilling Contractor:
Final Drill Date: 2015-06-21
Well Total Depth: 2488.00 ft
Configuration: Vertical
Latitude: 39.550000
Longitude: -82.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-06-12 Proposed Formations:TRENTON, BLACK RIVER, TREMPEALEAU,ROSE RUN, Issued Date:6/12/2015, Expired Date:6/11/2017 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2015-06-21
Completion Report Received 2015-09-28
Construction Permit Expires 2017-06-11
Record Last Modified 2017-10-23

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2015 WE ENERGY LLC 0.00 6705.00 142
2016 WE ENERGY LLC 0.00 2800.00 301
2017 WE ENERGY LLC 0.00 1525.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2015 WE ENERGY LLC Brine 0 142
2016 WE ENERGY LLC Brine 0 301
2017 WE ENERGY LLC Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-100786531 2016-5-9 0:00:0 PL No Violations 2.50
-1603139383 2017-11-24 0:00 PW No Violations 0.30
-2055910883 2019-6-6 0:00:0 PW No Violations 0.30
-711396011 2018-1-12 0:00: PW No Violations 0.30
-763725910 2015-6-22 0:00: DD No Violations 3.00
-772943214 2015-6-18 0:00: DD No Violations 8.00
0100786531 2016-05-09 Preliminary Restoration No Violations The purpose of this inspection is a status check on a preliminary restoration. During my inspection I witnessed the production equipment consists of six 210 bbl. tanks and two vertical separators. Production equipment is shared with wells 3412920590, 3412920580, 3412920258, 3412920217. Gravel lease road and the well is located in a Farmers crop field. Location has met 1509.072 A requirements and preliminary restoration has passed.
0417013877 2015-06-17 Drill / Deepen / Reopen No Violations Kilbarger rig number 1 reached 179 at 2:34AM. Formation cementing on site, 200 sacks of class A cement was ran with good cement returns.
0711396011 2018-01-12 Production Wells No Violations Production well inspection. The well consists of a pumping unit and 2-100 barrel tanks. The tanks are surrounded by an earthen dike. No violations noted.
0763725910 2015-06-22 Drill / Deepen / Reopen No Violations Kilbarger rig 1 reached total depth of 2488. Production casing was ran and cemented. The rig is moving to a Hocking Hills Energy well site.
0772943214 2015-06-18 Drill / Deepen / Reopen No Violations Kilbarger rig number 1 has reached 808. 760 of 7 surface casing has been ran in the well bore.
1433344796 2019-10-24 0:00 PW No Violations 0.50
1434468015 2015-06-16 Drill / Deepen / Reopen No Violations Kilbarger rig number 1 has spudded. The pits have been lined with 8 Mil reinforced fabric. They have reached 92 by 1530 hours. Conductor will be set using 3 centralizers.
1446126234 2015-10-29 Production Wells No Violations Production well inspection. The well has been put in production. The tanks have been painted. No violations noted.
1549648267 2017-06-02 Production Wells No Violations production well inspection. The well consists of a pumping unit and 2-100 barrel tanks. The tanks are surrounded by a earthen dike. No violations noted.
1597122024 2018-07-18 Production Wells No Violations My inspection revealed the well was in production during my inspection. The well consists of a pumping unit and 2-210 barrel tanks. Legible identification was posted.
1603139383 2017-11-24 Production Wells Violations Noted My inspection revealed the well is owned by WE Energy LLC. The well consists of a pumping unit and 5-210 barrel tanks. The well was venting gas through a 1 inch diameter hose. I contacted pumper Ron Uhlman to reconnect the gas to the flare stack. This well shares a common tank battery with 3412920217 and 3412920053. The tank battery is surrounded by a dike. Legible identification was posted.
417013877 2015-6-17 0:00: DD No Violations 6.00
635802421 2019-7-31 0:00: PW No Violations 1.30

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1603139383 US-OH-115730 2018-03-05 9-9-05(B) Unlawful venting or flaring of gas

For data sources see[7]