If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-131-20091 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.03,"lon":-82.83,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Pike | |
Municipality: Marion Township | |
Operator Name: PAXTON MADISON LLC | |
Well Pad ID: | |
Farm/Lease Name: BRUST J C | |
License Status: Final Restoration | |
License Date: 2007-09-05 | |
Spud Date: 2007-10-25 | |
Spud Drilling Contractor: BOWMAN DRILLING | |
Final Drill Date: 2007-10-26 | |
Well Total Depth: 389.00 ft | |
Configuration: Vertical | |
Latitude: 39.030000 | |
Longitude: -82.830000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-09-05 | Proposed Formations:OHIO SHALE, Issued Date:9/5/2007, Expired Date:9/4/2008 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-10-26 | |
Reached Total Depth | 2007-10-26 | |
Plugged/Abandoned | 2007-11-20 | |
Completion Report Received | 2008-01-24 | |
Construction Permit Expires | 2008-09-04 | |
Record Last Modified | 2013-03-14 |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | PAXTON MADISON LLC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | PAXTON MADISON LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1398116014 | 2009-5-21 0:00: | FR | No Violations | |
-1780412241 | 2007-11-20 0:00 | PB | No Violations | |
-960724872 | 2007-10-28 0:00 | PB | No Violations | |
0960724872 | 2007-10-28 | Plug / Plug Back | No Violations | Bowman has excavated out around the hole and is building it up with large stones. No water is coming out of the well at this time. Drill pipe is still in the hole. Conductor is still in the hole. Pit has been filled in does not look like the pit was pumped out before it was filled in. |
1194445027 | 2007-10-26 | Drill / Deepen / Reopen | No Violations | Spud date 10-25-2007. Air Rotary only ran 42 of conductor. Permit called for 60 min. if on air. TD 383 at 375 hit a large amount of water, The water filled up the 7 flow line. Some water came up on the back side of the conductor. Site started to subside. Driller cut off the drill pipe in the hole and skidded the rig away from the subsidence. A 40 area around the well site dropped 24-30. The pit water measured 1000ppm on a High End Quantab. They have to fill in the subsidence with large rocks. This has to be done before a rig can move on to the site. |
1204124612 | 2008-02-27 | Administrative Inspection | No Violations | I had received a call from Mark Bailey Paxtons Operations manager Re: has not been able to talk to Mr. Brust. Mark leaves messages and no one returns the call. I called the Brusts at 9:45am on 2-27-08 and talked to Mrs. Brust and gave her an update on their complaint. I told her that the electric to the well is shut off so it is not a hazard to their live stock. I told her about the restoration plan and the 9 month time frame to complete it. I informed her Paxtons plan to bury the electric line at the well head during restoration. I told her that the gravel on the road to the water tower is temporary and that Mark told me they will fix the road back to original condition during the restoration. I asked Mrs. Brust to please give this message to Mr. Brust and that they should call Mark soon so that the issue with the dead cow can be resolved. I gave Mrs. Brust Mark Baileys Cell phone number and My cell phone number. I told her to call me if they have any questions or problems in the future. |
1213624063 | 2008-06-05 | Final Restoration | No Violations | Restoration has not been completed yet. Site is saturated and so is the field leading to the site. I have contacted Paxton Madison and they are waiting for the ground to dry out. Then they are going to finish both the 20091 and the 20093. They are going to finish them at the same time. Plastic pit liner pieces are all over the ground. |
1222890300 | 2008-10-01 | Final Restoration | Violations Noted | Final restoration is not done. Pit liner pieces are sticking out of a pile of soil and drill cuttings. The disturbed area is 170 feet by 145 feet. 5 gallon buckets are partially buried on location. The top soil is in a pile. A soil sample was taken of the disturbed site. I received a call from the land owner Chris Brust on 9-30-08 he wanted to meet with me on location. I had a meeting with Mr. Brust on 10-1-08 to discuss the restoration violations. Mr. Brust is upset and wants take the companys bond. I explained that he cannot take the bond him self. Mr. Brust wants to approve of the contractors before they start the work. Mr. Brust also stated his concern for the access road to the water tower. The road has been recently resurfaced and is in good shape. |
1227102903 | 2008-10-06 | Final Restoration | No Violations | Meeting on location with Dale Stewart (contractor for Paxton Madison) We went over the scope of the work to be done. Remove the contaminated soil and replace it with good soil from a permitted location. Seed, lime, fertilize and mulch the site. I called Chris Brust (landowner) before the meeting and after the meeting to keep him informed on the progress. |
1313871779 | 2008-10-24 | Final Restoration | No Violations | Site graded. Seed and mulch applied. All debris removed from location and taken to landfill. Access road looks good. Took pictures of site. |
1338037968 | 2008-10-15 | Final Restoration | No Violations | 6 loads of debris has been removed and taken to a landfill. Site has been graded and they are installing the fence around the restoration today. No seed or mulch has been applied yet. |
1398116014 | 2009-05-21 | Final Restoration | No Violations | FR passed site looks good. Restoration area fenced in to keep cattle off site. Good vegetative cover established. |
1629240166 | 2007-10-30 | Plug / Plug Back | No Violations | Plugging lost hole. Tried to run 2 tubing down the hole. Could only get 2.5 joints down the hole. Getting hung up right bellow the conductor. Had to use 4 drill pipe to place the plugs. Set 3 plugs 100 each total of 300. Could not tell where the top of cement was at with the drill pipe and decided to stop plugging and wait on the service rig to finish the plugging. |
1780412241 | 2007-11-20 | Plug / Plug Back | No Violations | Ran tubing down and TD top of cement plug at 50. Circulated hole and pumped cement through tubing. Cement stayed at the top. |
1820343846 | 2007-11-19 | Plug / Plug Back | No Violations | I arrived on location and the service rig was set up on the Brust 1-A well completing the production casing cement job. I talked to the rig hands about the method they planed to use to finish the plug job on the #1. Dick Pulling said that he did not want to TD top of the cement and to just fill it with cement from the top. I said no they need to find the top of the cement and go from there. I told him that it should be 80 to the top of the cement if no fill up occurred. We compromised by using the 2 tubing to find the top of the plug. They did not have enough 2 tubing on site to do the job. We rescheduled for the next day. I suggested they bring a total of 120 of tubing to allow for any loss that could have occurred. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1222890300 | US-OH-106001 | 2008-10-01 | Failure to restore land surface within 6 months (CHANGE) |
For data sources see[7]