X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-133-21473

Well Details

Well ID: 34-133-21473
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Charlestown Township
Operator Name: B & B OILFIELD SERVICES INC
Well Pad ID:
Farm/Lease Name: FERRARA & FERRARA INC
License Status: Active Injection
License Date: 1988-08-05
Spud Date: 1978-06-08
Spud Drilling Contractor: DELTA DRILLING
Final Drill Date: 1978-07-05
Well Total Depth: 4533.00 ft
Configuration: Vertical
Latitude: 41.200000
Longitude: -81.190000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1978-05-24 260 TWINOAKS OIL & GAS CO GeoDate 5/24/78
Original Spud 1978-06-08 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
Completed 1978-07-05 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
Reached Total Depth 1978-07-05 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
CO 1988-08-05 260 TWINOAKS OIL & GAS CO GeoDate 8/5/88
Conversion to Injector 1988-08-05
Salt Water Injection Well 1988-08-05 Issued Date 8/5/88 Expired Date 8/5/89 Acres 0058020 Tool Type NT Proposed Formation NEWBURG Proposed Depth 00000 Proposed Drill Depth 00000
Storage Well 1988-08-05 Issued Date 8/5/88 Expired Date 8/5/89 Acres 0058020 Tool Type NT Proposed Formation NEWBURG Proposed Depth 00000 Proposed Drill Depth 00000
Plugged Back 1988-08-19 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
First Injection 1988-08-27 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
Construction Permit Expires 1989-08-05 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
Annulus Pressure Monitoring Approved 1997-02-25 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
Change of Owner 2004-11-29 Operator changed from 260, TWINOAKS OIL & GAS CO to 3436, B & B OILFIELD SER INC
Last Compliance Report 2014-03-05 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET
Record Last Modified 2017-10-19 COVERT 8-6-88 - SPECIFIC GRAVITY ADJUSTMENT TO MAXIMUM ALLOWABLE INJECTION PRESSURE TO 1215 PSI - TET

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-05 4409 4410 2
2000-05-05 4423 4426 7
2000-05-05 4417 4418 3
4169 4176 0
4395 4396 2
4409 4410 2
4417 4418 3
4420 4421 3
4431 4432 3
4435 4436 3
4460 4460 2
4169 4176 0
2000-05-05 4405 4405 2
2000-05-05 4169 4176 0
2000-05-05 4395 4396 2
2000-05-05 4435 4436 3
2000-05-05 4460 4460 2
2000-05-05 4431 4432 3
2000-05-05 4420 4421 3

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 2000 Gal 0
FOAM 0 0 Lbs 91600 1600 LBS OF WATER, 50,000 BLS OF 100 MESH AND 40,000 LBS OF 20/40 SAND
H2O 0 1600 Bbl 90000

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1099517743 2019-2-4 0:00:0 SW No Violations
-1170303263 2017-6-21 0:00: SW No Violations 1.00
-1186889465 2008-12-17 0:00 SW No Violations
-1284440370 2008-3-31 0:00: SW No Violations
-1310867745 2003-7-17 0:00: SW No Violations
-1367809878 2020-1-29 0:00: SW No Violations 1.00
-1390280194 2006-2-28 0:00: SW No Violations
-1520455209 2011-6-14 0:00: SW No Violations
-152419892 2016-9-28 0:00: SW No Violations
-1575899654 2019-2-20 0:00: SW No Violations 0.80
-1618852364 2013-9-25 0:00: SW No Violations
-1646627675 2019-6-25 0:00: SW No Violations 0.50
-1719688740 2016-3-24 0:00: SW No Violations
-1794938019 2002-4-24 0:00: SW No Violations
-1814706466 2006-12-11 0:00 SW No Violations
-1894009940 2013-6-12 0:00: SW No Violations
-198723090 2004-2-19 0:00: SW No Violations
-2001721559 2009-3-3 0:00:0 SW No Violations
-2059817421 2009-9-10 0:00: SW No Violations
-258088677 2008-8-25 0:00: SW No Violations
-275704762 2010-9-11 0:00: SW No Violations
-288464133 2014-1-10 0:00: SW No Violations
-314001160 2005-8-23 0:00: SW No Violations
-33136585 2015-3-30 0:00: SW No Violations
-421480655 2019-12-24 0:00 SW No Violations 1.50
-421507322 2012-3-28 0:00: SW No Violations
-437089165 2017-9-25 0:00: SW No Violations 0.70
-439281751 2019-10-21 0:00 SW No Violations 0.70
-462622723 2006-5-2 0:00:0 SW No Violations
-463305106 2014-1-13 0:00: SW No Violations 1.50
-568161232 2004-8-12 0:00: SW No Violations
-583967160 2014-1-16 0:00: SW No Violations
-590102265 2005-2-25 0:00: SW No Violations
-610490657 2009-11-17 0:00 SW No Violations
-67125542 2006-8-30 0:00: SW No Violations
-900435763 2018-2-12 0:00: SW No Violations 0.80
0000UIC897 1990-04-20 Salt Water Injection Well No Violations 1509.22 A STORAGE AND DISPOSAL
0001216i33 2001-11-07 Salt Water Injection Well No Violations No violations noted this date. Last inspection: 09-12-2001
0001879485 2002-04-24 Salt Water Injection Well No Violations Inspectors Claus and Worstall checked UIC pressures and inspected the facility. The injection system was operating during the inspection. Met with landowner/operator (Mr. Ferrara) and requested a general improvement in housekeeping practices.
0008479069 2002-03-14 Salt Water Injection Well No Violations Injection well was running at the time of the inspection. No Violations.
000UIC1064 1991-02-27 Salt Water Injection Well No Violations 1501:9-3-05 (A) (6) CONSTRUCTION
000UIC1065 1991-02-27 Salt Water Injection Well No Violations 1501:9-3-04 POLLUTION
000UIC1414 1993-05-05 Salt Water Injection Well No Violations 1509.03 RULES & REGULATIONS
000UIC1415 1993-05-05 Salt Water Injection Well No Violations 1501: 9-3-04 (A) PREVENT CONTAMINATE
000UIC1445 1993-08-20 Salt Water Injection Well No Violations ACTION 940218 1509.22 (A) (2) STORAGE & DISPOSAL
000UIC1446 1993-08-20 Salt Water Injection Well No Violations 1501: 9-3-04 PREVENT CONTAMINATE
000UIC1447 1993-08-20 Salt Water Injection Well No Violations 1509.072 RESTORATION
000UIC1450 1993-11-22 Salt Water Injection Well No Violations 1509.22 (A) (2) STORAGE & DISPOSAL
000UIC1451 1993-11-22 Salt Water Injection Well No Violations 1501: 9-3-04 (A) PREVENT CONTAMINATE
000UIC1669 1997-06-10 Salt Water Injection Well No Violations 1501:9-3-07(H),1501:9-3-8 EMPTY PITS
002154i245 2002-06-25 Salt Water Injection Well Violations Noted 4-24-02 Inspectors Claus and Worstall requested Mr. Ferrara to install new needle valves at the wellhead and informed him that the injection pump shed should be cleaned up. 5-29-02 Inspector Claus showed Jay Cheslock (North Region Assistant Manager) the injection pump shed. Mr. Cheslock agreed that the pump shed should be cleaned up. 6-25-02 System was not running. Unable to get an injection pressure reading due to a bad needle valve. Met with Mr. Ferrara and requested him to replace the injection needle valve and the annulus needle valve. The pump shed still needs cleaned up. Issued N.O.V.
002154i395 2002-08-22 Salt Water Injection Well Violations Noted Needs additional clean-up in pump house. System was running.
0033136585 2015-03-30 Salt Water Injection Well Violations Noted On the tubing, a 1/4 inch nipple was dripping. The well owner, Dave Ballentine, was notified of the problem and instructed to make repairs as soon as possible.
0066112147 2015-09-18 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0067125542 2006-08-30 Salt Water Injection Well No Violations Quarterly status check inspection. No violations at this time.
0096546938 2018-11-14 Salt Water Injection Well No Violations I found the injection well not in operation on the day of my inspection. I observed no spills or leaks. The facility is in good repair. Identification signs are posted.
0131618200 2010-05-20 Salt Water Injection Well No Violations Quarterly status check inspection found no violations at this time. Used the company gauge for the annulus pressure.
0145448939 2014-09-09 Salt Water Injection Well No Violations The oil clean-up was completed. The well site was restored. The well was found in compliance.
0152419892 2016-09-28 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0198723090 2004-02-19 Salt Water Injection Well No Violations Status check inspection - no violations at this time. Could not get an annular pressure due to valve frozen or seized. Both the tank battery and the well have proper identification. 180# injection.
0243447461 2017-04-26 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0258088677 2008-08-25 Salt Water Injection Well No Violations Quarterly status check inspection found no violations at this time. The well is operating below the maximum allowable injection pressure.
0275704762 2010-09-11 Salt Water Injection Well No Violations Heagan successfully recovered the remaining 2-3/8 tubing and the old packer. On this morning Heagan ran a reconditioned Halliburton R-4 packer on a string of 2-7/8 tubing. I witnessed the packer going in the hole and Inspector Roberts witnessed the MIT. After the packer reached setting depth, five gallons of inhibitor was mixed with 80 bbl of fresh water and the mixture was pumped down the tubing and up through the annulus until the inhibitor mixture circulated to surface. The packer was set in tension at 4118.5 by pulling 15,000# over string weight. The annulus was pressured up to 1198 psi. After 15 minutes, the annulus pressure had fallen to 1181 psi for a total loss of 17 psi. The pressure loss was well below the allowed loss of 60 psi. The MIT was successful and the Compliance Notice is resolved.
0288464133 2014-01-10 Salt Water Injection Well No Violations Service rig was running into the well in order to tag bottom. No violations were found.
0314001160 2005-08-23 Salt Water Injection Well No Violations Status check inspection - no violations at this time. I spoke with Dave Ballentine about cleaning up the tank battery and maintenance around the wellhead. He stated that he intended to complete the tank battery and maintenance work this fall.
0411837238 2014-07-22 Salt Water Injection Well Violations Noted Oil was pooling on the closed work over pit. Dave Balentine was instructed to clean up the oil and restore the well site.
0421507322 2012-03-28 Salt Water Injection Well No Violations No violations were found at the time of inspection.
0437089165 2017-09-25 Salt Water Injection Well No Violations Status check inspection of this salt water disposal well. I was on location with DOGRM District Supervisor Steve Ochs to conduct quarterly status checks for the UIC Program. The well was currently injecting at a pressure of 325psi. The pressure on the annulus between the 2.75 injection tubing and 4.5 casing was 0psi. No violations.
0437918227 2005-06-01 Salt Water Injection Well No Violations Status check inspection for this salt water disposal well. Ownership of the well recently changed to B&B from Twinoaks. The 210 bbl tanks need to repaired of replaced and the pumphouse needs to be cleaned. I will contact Dave Ballentine about starting this work. No violations at this time.
0448725675 2007-05-09 Salt Water Injection Well No Violations Quarterly status check found no violations at this time.
0462622723 2006-05-02 Salt Water Injection Well No Violations Status check inspection found no violations at this time. I did talk to Dave Ballentine and told him to reclaim the disturbed area around the wellhead, replace the damaged ID sign and paint the tank battery.
0463305106 2014-01-13 Salt Water Injection Well No Violations I was on location with Inspector Steve Ochs to observe workover operations on this well. The operator discovered that there was a hole in the 4.5 casing and were running a bond log to find the top of the cement. Their plan was to run in with tubing and a packer and pressure test zones to find the hole. No violations.
0481326628 2015-10-27 Salt Water Injection Well No Violations The well passed a mechanical integrity test.

A pressure of 1500 psi. was placed on the tubing-casing annulus. There was no pressure loss during a fifteen minute period.

0528747897 2010-09-10 Salt Water Injection Well No Violations Heagen Well Service is on site to release and unseat the old Halliburton R-4 packer. When pulling the packer, the tubing parted. At this time, Heagen was picking up fishing tools and will attempt to recover the remaining tubing and the packer. If successful, the new packer and a new string of 2-7/8 tubing will be run in the hole tomorrow.
0568161232 2004-08-12 Salt Water Injection Well No Violations Salt water disposal well - no violations at this time. I will contact Twinoaks regarding a replacement schedule for three of the four 210 bbl tanks. The tanks are deteriorating and need attention.
0583967160 2014-01-16 Salt Water Injection Well No Violations The service rig was drilling out the composite bridge plug. All conditions were acceptable.
0590102265 2005-02-25 Salt Water Injection Well No Violations Status check inspection of this salt water disposal well and storage system. No violations at this time.
0610490657 2009-11-17 Salt Water Injection Well No Violations Quarterly status check inspection found no violations at this time.
0634615893 2009-06-10 Salt Water Injection Well No Violations The trash and debris have been removed from in and around the tank battery and the pump house as requested. While they were not leaking this day, there is still concern for the condition of the manway hatch seals on the easternmost tanks. They will need to checked regularly.
0718254906 2009-05-21 Salt Water Injection Well No Violations I called Dave Ballentine about removing impacted vegetation around the wellhead and cleaning up trash and debris around the tank battery.
0808607029 2002-06-25 Salt Water Injection Well Violations Noted FOLLOW UP TO NOV # 2154i245 4-24-02 Inspectors Claus and Worstall requested Mr. Ferrara to install new needle valves at the wellhead and informed him that the injection pump shed should be cleaned up. 5-29-02 Inspector Claus showed Jay Cheslock (North Region Assistant Manager) th
0844038743 2012-12-18 Surface Facility Construction No Violations My inspection of the injection facility found no violations. Sod was installed on the dike walls.
0900435763 2018-02-12 Salt Water Injection Well No Violations I was on location to inspect the UIC well and facility. I found the well not in operation on the day of my inspection. I found no spills or leaks. The proper identification signs are posted at the facility and well. There are no violations at this time.
0905534748 2014-01-17 Salt Water Injection Well No Violations A Baker Hughes Lok set packer was set in compression at 4086 feet. A mechanical integrity test was performed on the well. 1410 psi. of pressure was placed on the tubing/casing annulus. The test passed.
0907131595 2014-03-07 Salt Water Injection Well No Violations The work over pit was closed. The lease road and well site will need restored, when the weather permits. There were no violations at the time of inspection.
0973781457 2016-06-21 Salt Water Injection Well No Violations I conducted a quarterly inspection of this salt water disposal well. My inspection found the well head equipped with 2.875 injection tubing, 4.5 production casing, and 8.626 surface casing. The well is currently injecting through the tubing at a pressure of 370psi. A gauge on the annulus between the tubing and production casing indicates a pressure of 210psi and a gauge on the production casing-surface casing annulus reads 4psi. The surface facilities (tank battery and pump house) were inspected and I found no leaks or contamination. No violations.
1014468226 2010-08-31 Salt Water Injection Well No Violations Quarterly status check inspection found that the injection pressure and annulus pressure had equalized at 680 psi. The injection pump was running at the time. I contacted Dave Ballentine and told him of the problem and requested that the system be shut down until the problem can be corrected. He will schedule a MIT as soon as possible.
1046618771 2019-2-1 0:00:0 SW No Violations
1078078730 2009-08-27 Salt Water Injection Well No Violations Status check inspection found the injection pressure and the annulus pressure nearly equal. The injection pressure could not be verified with the MRM issued gauge due to the fact that the B&B gauge could not be removed. I advised the company that the pressures would be rechecked next week and if they remained nearly equal or equal, a MIT would be required.
1101777927 2004-11-18 Salt Water Injection Well No Violations I received a call from Red Davis with Twinoaks informing me that this disposal well has been sold to B&B Oilfield Services (Dave Ballentine). I spoke with Dave Balentine and told him what was necessary to get this well back into operation. The leaking 210 bbl storage tanks need to be repaired or replaced and the pump house needs cleaned out. Ballentine said that he planned to replace three 210 bbl tanks with two 300 bbl horizontal tanks.
1130949139 2005-10-24 Salt Water Injection Well No Violations Witnessed pulling, reconditioning, and running Halliburton R-4 packer. Witnessed MIT on the packer. Test passed.
1135263691 2005-12-06 Salt Water Injection Well No Violations Completed a MIT on the 2 injection line from the pump house to the wellhead. The test was conducted with Barton Well Service. The initial shut in pressure was 1180 psi, after 5 minutes the pressure was 1180 psi and after 15 minutes, the pressure was 1180 psi. The injection line passed the MIT.
1170303263 2017-06-21 Salt Water Injection Well No Violations Quarterly status check inspection of this saltwater disposal well. The pump is currently off, the filter pumps are running, and gauges at the wellhead indicate a pressure of 360psi on the injection tubing and an annular pressure of 90psi on the 4.5 casing. The facility is in good order. I found no violations at this time.
1186889465 2008-12-17 Salt Water Injection Well No Violations Status check inspection found no violations at this time.
1189627869 2007-08-30 Salt Water Injection Well No Violations Quarterly status check inspection found no violations at this time.
1212092734 2008-05-21 Salt Water Injection Well No Violations Quarterly status check inspection found no violations at this time.
1216i33 2001-11-7 0:00: SW No Violations 1.00
1284377435 2010-09-11 Salt Water Injection Well No Violations I witnessed the running in the hole with 2 7/8 tubing. The tubing length is 4115.55. The B & B pump truck pumped 63 barrels of fresh water with Halliburton corrosion inhibitor AN HIBII. The Halliburton R-4 packer was set at 4118.55 in 15,000# tension. The annulus was pressured up to 1198 psi. The pressure after 5 minutes was 1198 psi. The 15 minute pressure was 1181 psi. This well passed MIT.
1284440370 2008-03-31 Salt Water Injection Well No Violations Quarterly status inspection found no violations at this time. I did call Dave Ballentine and requested that he attend to several housekeeping issues around the loading pad and tank battery.
1301579988 2011-11-02 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time.
1302293285 2011-03-21 Salt Water Injection Well No Violations Quarterly status check inspection found no violations at this time. The vault associated with the loading pad was full and I contacted Dave Ballentine and asked that the vault be emptied.
1310867745 2003-07-17 Salt Water Injection Well No Violations Status check inspection - the needle valves on both the injection and annular sides are heavily corroded and need to be replaced.
131618200 2010-5-20 0:00: SW No Violations
1324557525 2011-12-21 Salt Water Injection Well No Violations John Fleming and myself witnessed the pressure testing of the injection line from the tank battery to the wellhead by Dave Balentine. The line was pressured up to 1200 PSI and there was no pressure lost in 15 minutes. The injection line passed and there were no violations at this time.
1360093060 2012-11-13 Surface Facility Construction No Violations My inspection of the surface facility found the new tank battery dike constructed. The liner was installed. The operator was in the process of spreading out sand over the liner. All completed construction was acceptable.
1390280194 2006-02-28 Salt Water Injection Well No Violations Salt water disposal well quarterly status check. No violations at this time.
1390923104 2014-01-17 Salt Water Injection Well No Violations I was on location with inspector Steve Ochs to witness the setting of the packer and the mechanical integrity test (MIT) at this active injection well. Petrowell, Nabors, Pryamid Pipeline, Baker Atlas, and Northeast Ohio Oilfield Services were on location conducting operations. Petrowell ran 2.875 tubing into the hole with a packer and an on/off tool and set the packer. They came off of the tool and Nabors began circulating the hole with freshwater and pumped 3 gallons of corrosion inhibitor into the annulus between the tubing and 4.5 casing. Pyramid pumped diesel fuel to fill the top of the annulus to prevent freezing and damage to the casing and tubing in cold conditions. The tubing was placed back on the on/off tool and Nabors rigged up to conduct the MIT test. The test was conducted at 1410psi and after 15 minutes the pressure had not dropped. The test passed and the well can resume operations. See Inspector Ochs report for details on this job. No violaltions.
1404327282 2014-06-30 Salt Water Injection Well No Violations There were no violations at the time of inspection.
1433981518 2010-09-02 Salt Water Injection Well No Violations The quarterly status check inspection found that the injection and annulus pressures were equalized indicating that the packer or tubing has failed. Barton Well Treating was on site to complete a mechanical integrity test on the annulus. The annular pressure increased less than 100 psi after pumping four barrels of water. Dave Ballentine is scheduling a service rig to unseat and pull the packer.
145448939 2014-9-9 0:00:0 SW No Violations
1509454568 2017-10-31 Salt Water Injection Well No Violations I found the UIC facility in good repair on the day of my inspection. The proper identification sign is posted at the facility and well. There is a wire fence around the tank battery. The dike is in good repair and covered with vegetation. I observed no leaks or spills. There are no violations at this time.
1520455209 2011-06-14 Salt Water Injection Well No Violations Quarterly status check inspection found no violations at this time. The company pressure gauge on the annulus was broken but could not be removed to check the annulus pressure. I asked B&B to replace the gauge.
1524827601 2018-04-26 Salt Water Injection Well No Violations I was on location for an UIC facility inspection. I found the injection in operation on the day of my inspection. I observed no leaks or spills. Identification signs are posted. There are no violations at this time.
1532973294 2018-07-30 Salt Water Injection Well No Violations I found the injection well in operation on the day of my inspection. There are identification signs posted. I observed no leaks or spills. There is fencing around the diked tank battery. There was no facility operator on location.
1536947026 2018-09-14 Salt Water Injection Well No Violations I found the injection well operating on the day of my inspection. There is wire fencing around the facility. Identification signs are posted. I observed no leaks or spills. A Northeast Ohio Oilfield brine truck arrived on location with the proper UIC number displayed (#25-222).
1548836629 2014-12-30 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1549547195 2019-2-7 0:00:0 SW No Violations 1.00
1552915180 2019-3-18 0:00: SW No Violations 1.30
1557149113 2019-5-6 0:00:0 SW No Violations 1.50
1600356393 2020-9-17 0:00: SW No Violations 1.40
1618852364 2013-09-25 Salt Water Injection Well No Violations My inspection of the well and injection facility found no violations.
1637266940 2011-08-03 Salt Water Injection Well No Violations I performed the quarterly UIC test on the annulus and the injection. The well was running. There were no violations at this time.
1684639158 2014-01-14 Salt Water Injection Well No Violations A contractor was running a bond log. No violations were found.
1719688740 2016-03-24 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1794938019 2002-04-24 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 18 Inspectors Claus and Worstall checked UIC pressures and inspected the facility. The injection system was operating during the inspection. Met with landowner/operator (Mr. Ferrara) and requested a general improvement in housekeeping practices.
1814706466 2006-12-11 Salt Water Injection Well No Violations Quarterly status inspection found no violations at this time.
1879485 2002-4-24 0:00: SW No Violations
1894009940 2013-06-12 Salt Water Injection Well No Violations My inspection of the well and surface facility found no violations.
1896047310 2019-8-19 0:00: SW No Violations 1.20
2001721559 2009-03-03 Salt Water Injection Well No Violations Quarterly status check inspection found general housekeeping issues at this time. The concrete vault connected to the slit drain in the unloading pad is full and needs to be pumped. Used sock filters need to be picked up inside of the pump house. A pressure valve failed at the wellhead and sprayed a small 3x3 area. The impacted vegetation needs to be removed and the valve replaced.
2059817421 2009-09-10 Salt Water Injection Well No Violations Status check inspection found that the injection and annulus pressures are still close but not equalized. I still could not verify the injection pressure with the MRM gauge.
2154i245 2002-6-25 0:00: SW No Violations 1.00
2154i395 2002-8-22 0:00: SW No Violations 1.00
243447461 2017-4-26 0:00: SW No Violations
411837238 2014-7-22 0:00: SW No Violations
437918227 2005-6-1 0:00:0 SW No Violations
448725675 2007-5-9 0:00:0 SW No Violations
481326628 2015-10-27 0:00 SW No Violations
528747897 2010-9-10 0:00: SW No Violations
634615893 2009-6-10 0:00: SW No Violations
66112147 2015-9-18 0:00: SW No Violations
718254906 2009-5-21 0:00: SW No Violations
808607029 2002-6-25 0:00: SW No Violations 1.00
844038743 2012-12-18 0:00 SC No Violations
8479069 2002-3-14 0:00: SW No Violations 2.50
905534748 2014-1-17 0:00: SW No Violations
907131595 2014-3-7 0:00:0 SW No Violations
96546938 2018-11-14 0:00 SW No Violations 1.00
973781457 2016-6-21 0:00: SW No Violations 0.50
985577790 2019-2-5 0:00:0 SW No Violations 0.70
iTOMK00008 2000-07-13 Salt Water Injection Well Violations Noted
iTOMK000081 2000-7-13 0:00: SW No Violations
UIC1064 1991-2-27 0:00: SW No Violations
UIC1065 1991-2-27 0:00: SW No Violations
UIC1414 1993-5-5 0:00:0 SW No Violations
UIC1415 1993-5-5 0:00:0 SW No Violations
UIC1445 1993-8-20 0:00: SW No Violations
UIC1446 1993-8-20 0:00: SW No Violations
UIC1447 1993-8-20 0:00: SW No Violations
UIC1450 1993-11-22 0:00 SW No Violations
UIC1451 1993-11-22 0:00 SW No Violations
UIC1669 1997-6-10 0:00: SW No Violations
UIC897 1990-4-20 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
002154i245 US-OH-122076 2002-06-27 Pollution/Contamination
002154i245 US-OH-122077 2002-06-27 Violation of injection tubing/fitting requirements
002154i395 US-OH-121998 2002-08-22 Pollution/Contamination
0033136585 US-OH-123468 2015-04-23 Pollution/Contamination
0411837238 US-OH-124369 2014-10-06 Pollution/Contamination
0808607029 US-OH-129199 2002-06-27 Pollution/Contamination
0808607029 US-OH-129200 2002-06-27 Violation of injection tubing/fitting requirements
iTOMK00008 US-OH-131622 Violation of injection tubing/fitting requirements

For data sources see[5]

References