If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-133-23343 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.34,"lon":-81.08,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Portage | |
Municipality: Nelson Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: ENERGY OPERATING SERVICES INC | |
License Status: Active Injection | |
License Date: 1985-01-02 | |
Spud Date: 1985-04-19 | |
Spud Drilling Contractor: PEYTON DRLG | |
Final Drill Date: 1985-04-25 | |
Well Total Depth: 3990.00 ft | |
Configuration: Vertical | |
Latitude: 41.340000 | |
Longitude: -81.080000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1985-01-02 | 9 EDC GeoDate 1/2/85 |
Conversion to Injector | 1985-01-02 | |
Salt Water Injection Well | 1985-01-02 | Issued Date 1/2/85 Expired Date 7/1/85 Acres 0018000 Tool Type RTF Proposed Formation NEWBURG Proposed Depth 03960 Proposed Drill Depth 03960 |
Storage Well | 1985-01-02 | Issued Date 1/2/85 Expired Date 7/1/85 Acres 0018000 Tool Type RTF Proposed Formation NEWBURG Proposed Depth 03960 Proposed Drill Depth 03960 |
Original Spud | 1985-04-19 | |
Completed | 1985-04-25 | |
Reached Total Depth | 1985-04-25 | |
First Injection | 1985-06-10 | |
Construction Permit Expires | 1985-07-01 | |
Completion Report Received | 1985-10-25 | |
Annulus Pressure Monitoring Approved | 1994-12-07 | |
Change of Owner | 2008-07-21 | Operator changed from 9, POWER GAS MARKETING & TRANS to 1388, EXCO - NORTH COAST ENERGY INC |
Change of Owner | 2009-12-14 | Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC |
Last Compliance Report | 2010-10-28 | |
Record Last Modified | 2017-10-19 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-05 | 3896 | 3902 | 4 |
2000-05-05 | 3924 | 3940 | 3 |
3896 | 3902 | 4 | |
3924 | 3940 | 3 | |
3896 | 3902 | 4 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 28 | 4300 Gal | 0 | |||
ACID | 15 | 4800 Gal | 0 | 500 GALLONS OF 15% HCL AND 4300 GALLONS OF 28% HCL |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | POWER GAS MARKETING & TRANS | 0.00 | 808.00 | 0 |
1996 | POWER GAS MARKETING & TRANS | 0.00 | 879.00 | 0 |
2010 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 0 |
2011 | ENERVEST OPERATING LLC | 0.00 | 0.00 | 0 |
2012 | ENERVEST OPERATING LLC | 0.00 | 573.00 | 366 |
2013 | ENERVEST OPERATING LLC | 0.00 | 315.00 | 365 |
2014 | ENERVEST OPERATING LLC | 0.00 | 90.00 | 365 |
2016 | ENERVEST OPERATING LLC | 0.00 | 147.00 | 116 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | POWER GAS MARKETING & TRANS | Brine | 0 | 0 |
1996 | POWER GAS MARKETING & TRANS | Brine | 0 | 0 |
2010 | ENERVEST OPERATING LLC | Brine | 0 | 0 |
2011 | ENERVEST OPERATING LLC | Brine | 0 | |
2012 | ENERVEST OPERATING LLC | Brine | 0 | 366 |
2013 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2014 | ENERVEST OPERATING LLC | Brine | 0 | 365 |
2016 | ENERVEST OPERATING LLC | Brine | 0 | 116 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1011192924 | 2003-11-18 0:00 | SW | No Violations | |
-1069159768 | 2010-8-26 0:00: | SW | No Violations | |
-1078442613 | 2011-3-9 0:00:0 | SW | No Violations | |
-1103609446 | 2010-9-14 0:00: | SW | No Violations | |
-1126694830 | 2002-6-25 0:00: | SW | No Violations | 1.00 |
-1191071925 | 2004-11-10 0:00 | SW | No Violations | |
-1227420643 | 2003-10-30 0:00 | SW | No Violations | |
-1284686363 | 2008-11-17 0:00 | SW | No Violations | |
-1357880468 | 2017-9-25 0:00: | SW | No Violations | 0.60 |
-1410088376 | 2009-8-27 0:00: | SW | No Violations | |
-1523630720 | 2010-3-18 0:00: | SW | No Violations | |
-1542894103 | 2016-9-1 0:00:0 | SW | No Violations | |
-1586641079 | 2004-5-10 0:00: | SW | No Violations | |
-1634010171 | 2009-3-19 0:00: | SW | No Violations | |
-1664294016 | 2018-3-13 0:00: | SW | No Violations | 0.70 |
-1678209742 | 2003-11-5 0:00: | SW | No Violations | |
-1715775605 | 2010-7-20 0:00: | SW | No Violations | |
-183656593 | 2006-5-2 0:00:0 | SW | No Violations | |
-1881535261 | 2008-8-19 0:00: | SW | No Violations | |
-2026253589 | 2018-6-25 0:00: | SW | No Violations | 0.80 |
-2096990412 | 2008-12-22 0:00 | SW | No Violations | |
-2110956842 | 2008-10-31 0:00 | SW | No Violations | |
-225173830 | 2003-10-27 0:00 | SW | No Violations | |
-258176827 | 2020-1-21 0:00: | SW | No Violations | 1.40 |
-310080740 | 2007-5-8 0:00:0 | SW | No Violations | |
-33504916 | 2017-3-31 0:00: | SW | No Violations | |
-341063392 | 2003-10-28 0:00 | SW | No Violations | |
-346410184 | 2018-11-14 0:00 | SW | No Violations | |
-434191908 | 2004-1-5 0:00:0 | SW | No Violations | |
-445839753 | 2018-3-1 0:00:0 | SW | No Violations | 0.80 |
-474948021 | 2003-6-17 0:00: | SW | No Violations | |
-494585435 | 2014-6-30 0:00: | SW | No Violations | |
-535552208 | 2010-9-13 0:00: | SW | No Violations | |
-687721492 | 2008-11-5 0:00: | SW | No Violations | |
-690913315 | 2003-10-9 0:00: | SW | No Violations | |
-694900603 | 2015-9-29 0:00: | SW | No Violations | |
-714657768 | 2003-9-18 0:00: | SW | No Violations | |
-798785364 | 2020-5-27 0:00: | SW | No Violations | 1.00 |
-845109808 | 2019-9-11 0:00: | SW | No Violations | 1.00 |
-875863494 | 2006-6-20 0:00: | SW | No Violations | |
-908525184 | 2019-12-2 0:00: | SW | No Violations | 0.50 |
-912288490 | 2006-2-23 0:00: | SW | No Violations | |
-961672675 | 2019-7-17 0:00: | SW | No Violations | 0.50 |
-967659162 | 2003-4-17 0:00: | SW | No Violations | |
0000UIC249 | 1987-06-03 | Salt Water Injection Well | No Violations | 1501:9-3-07(E)(F) |
0000UIC350 | 1987-09-14 | Salt Water Injection Well | No Violations | 1501:9-3-07 (E)(F) |
0000UIC938 | 1990-06-18 | Salt Water Injection Well | No Violations | 1509.226(C) SURFACE APPLICATION |
0006379055 | 2002-02-28 | Salt Water Injection Well | No Violations | Well was not running. No Violations. |
000UIC1023 | 1990-10-01 | Salt Water Injection Well | No Violations | 1509.03 |
000UIC1818 | 2000-01-27 | Salt Water Injection Well | No Violations | 1509.22 POLLUTION - LEAK |
002154i128 | 2002-04-24 | Salt Water Injection Well | No Violations | Well was not running at time of inspection. Noticed kill area on North side of concrete containment and fresh crude on South side of concrete containment. Spoke with John Firko in person at Power Gas Marketing office (330-527-5630). He said the areas would be cleaned up and seeded. Areas will be checked at next inspection. NO VIOLATIONS. |
002154i249 | 2002-06-25 | Salt Water Injection Well | Violations Noted | 4-24-02 Met with John Firko at the site and informed him that the kill area on the north side of the concrete containment and the spill area on the south side of the concrete containment needed cleaned up and seeded. Also the area around the injection pump needed cleaned up. 6-10-02 Met with John Firko at the site. Nothing has been cleaned up. 6-25-02 System was not running. Nothing was cleaned up or seeded. Issued N.O.V. |
002154i324 | 2002-07-29 | Salt Water Injection Well | Violations Noted | Nothing has been cleaned up or seeded. Met with John Firko and suggested that he initiate the clean up and seeding immediately. System was not running. |
002154i393 | 2002-08-21 | Salt Water Injection Well | Violations Noted | Violations still exist. System was not running. |
0033504916 | 2017-03-31 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
0107838081 | 2003-11-25 | Salt Water Injection Well | No Violations | Status check inspection on disposal pressures. No violations at this time. |
0183656593 | 2006-05-02 | Salt Water Injection Well | Violations Noted | Status check inspection found that the UIC numbers had been removed from the two salt water trucks that were on site. One truck had an Ohio license plate PEW2187 and the other truck had a Pennsylvania license plate AF25709. A call to Tom Tomastik also found that Power Gas did not submit the required plans for modifying the disposal system. These plans were requested on February 23, 2006. Power Gas must shut down the disposal system until the required pland have been provided and approved and the brine trucks have the required identification. |
0225173830 | 2003-10-27 | Salt Water Injection Well | Violations Noted | Power Gas has begun excavating around the concrete settling pond walls and repairing the cracks. They also emptied and lined the emergency containment pit on the north side. As long as work progresses in a timely manor, no additional action will be taken. |
0256704006 | 2003-09-25 | Salt Water Injection Well | Violations Noted | The concrete containment dike is still leaking into the earthen pit dug on the northeast side of the settling ponds. The system must be repaired to prevent this release of oil and brine. |
0299591256 | 2010-09-10 | Salt Water Injection Well | No Violations | Whipstock is attempting to back off the damaged 4-1/2 casing to replace with new pipe. The casing appeared to be backing off at approximately 800+ feet which exceeded the amount of casing available on site. The casing was reconnected and activity ended for the day. Work will resume on Monday 9/13. |
0310080740 | 2007-05-08 | Salt Water Injection Well | No Violations | Quarterly status check found no violations at this time. |
0341063392 | 2003-10-28 | Salt Water Injection Well | Violations Noted | Work is continuing on repairing the concrete pond walls. The cracks are being exposed, cleaned and patched with DAP concrete caulk. The label indicates that the caulk is resistant to oil and salt. |
0346410184 | 2018-11-14 | Salt Water Injection Well | No Violations | I found the injection well not operating on the day of my inspection. There was no facility operator on location. I observed no leaks or spills. Identification signs are posted. |
0347784271 | 2010-07-15 | Salt Water Injection Well | No Violations | Rick Kepler with Enervest called and reported a brine storage tank at this facility has been overfilled. The unknown quantity of brine was contained in the dike area and they were in the process of flushing the dike with fresh water. Hi-Range Quantab analysis of the water inside of the dike exceeded the maximum detectable level. Flushing and recovery will continue until the chloride levels are down to acceptable levels. |
0405288274 | 2009-05-12 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. |
0409177066 | 2010-12-16 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. The valves were frozen so pressures were read from the two pen chart recorder. |
0429069536 | 2003-06-17 | Salt Water Injection Well | Violations Noted | FOLLOW UP TO NOV # -474948021 UIC status check inspection. The northeast corner of the concrete settling pond was again topped and oil and brine were released. The impacted area extended approximately 40 feet to the north and 15 feet from east to west. The release killed the grass wh |
0434191908 | 2004-01-05 | Salt Water Injection Well | Violations Noted | The system has not been repaired. The proposal for temporarily repairing the containment system has been approved but has not been implemented. Power Gas claims to be waiting for the weather to improve before beginning implementation. |
0438112027 | 2008-05-14 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. |
0445839753 | 2018-03-01 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well and facility. I found the wellhead in good repair. I received a call from Enervest stating the annulus had been pressured up per my request. Identification signs are posted. An Enervest brine truck arrived on location with the proper UIC number displayed (#25-386). |
0474948021 | 2003-06-17 | Salt Water Injection Well | Violations Noted | UIC status check inspection. The northeast corner of the concrete settling pond was again topped and oil and brine were released. The impacted area extended approximately 40 feet to the north and 15 feet from east to west. The release killed the grass which had just been planted and mulched from a spill discovered on April 15, 2003. The settling pond must be repaired and/or modified to correct this situation. |
0478048131 | 2006-12-11 | Salt Water Injection Well | Violations Noted | NOV follow-up and quarterly status inspection found no violations at this time. |
0494585435 | 2014-06-30 | Salt Water Injection Well | No Violations | An inspection of the well and injection facility found no violations. |
0519189261 | 2004-05-20 | Salt Water Injection Well | No Violations | Power Gas is continuing to repair and rebuild the disposal well pit system. On this date, Stamm Contracting was pouring the new concrete pad for the three 210 bbl tanks. 22.5 cubic yards of concrete was poured over a prepared bed of bankrun gravel. The mix was 6.5 sacks per yard with one pound per yard of fiber and two pounds per yard of calcium chloride. Underneath the concrete and over the bankrun gravel was a double layer of 20 mil plastic. Expansion joints were placed around the new pad. The violations are corrected. |
0535552208 | 2010-09-13 | Salt Water Injection Well | No Violations | Enervest pulled and replaced the top joint of 4-1/2 casing and started the R-4 packer back in the hole. The packer will be set tomorrow followed by the MIT scheduled for 12:00. |
0560783797 | 2009-11-13 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. Met with no one on site. |
0604454622 | 2008-12-17 | Salt Water Injection Well | No Violations | Sutton is on site to steam clean the old concrete containment system prior to demolition. According to Joe Shepherd, they intend to remove the north wall and the center wall and backfill the area with subsoil material available on site. The concrete pads located west, east and southeast of the old containment system may remain for surface storage of supplies. The new aboveground storage system is nearing completion. As soon as it is completed, I will witness a MIT on the new injection pipeline and a mini MIT on the injection well. |
0675022396 | 2011-05-18 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. |
0687721492 | 2008-11-05 | Salt Water Injection Well | No Violations | North Coast personnel were on site to install the new 30 mil 60x100 liner. The floor of the earthen dike has been covered with 3 of sand. The liner was placed up and over the containment dike and an additional 3 of sand was placed on top of the liner. Road mat was placed over the liner and the floor of the containment area was covere with pea gravel. |
0690913315 | 2003-10-09 | Salt Water Injection Well | Violations Noted | Inspected site with Tom Tomastik. The emergency containment pond has not been closed in and the concrete dike walls are cracked and needs to be repaired. Met with John Firko and restated his obligations and our requirements. Failure to comply will result in notification to USEPA in Chicago. |
0694900603 | 2015-09-29 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
0714657768 | 2003-09-18 | Salt Water Injection Well | Violations Noted | Status check inspection. Pollution violations on the north side of the concrete settling pond. The earthen pit must be pumped out and closed in. The concrete dike must be repaired to prevent further releases. |
0763519043 | 2011-08-04 | Salt Water Injection Well | No Violations | I performed the quarterly UIC test on the annulus and the injection. The well was not running. There were no violations at this time. |
0786583713 | 2010-09-02 | Salt Water Injection Well | No Violations | Whipstock is on site to unseat and pull the packer after the well failed a mechanical integrity test. |
0819122446 | 2018-04-02 | Salt Water Injection Well | No Violations | I was on location for an UIC facility inspection. I found the injection not in operation on the day of my inspection. I observed no leaks or spills. Identification signs are posted. There are no violations at this time. |
0827659748 | 2004-08-12 | Salt Water Injection Well | No Violations | Salt water disposal well - status check inspection. Work is continuing toward site clean-up and improvements. |
0846187455 | 2013-12-30 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0862400859 | 2016-05-12 | Salt Water Injection Well | No Violations | I conducted a quarterly status check inspection of this active injection well and the associated surface facilities with Inspector John Fleming. The pump was not currently running and a gauge on the injection tubing indicated a pressure of 200psi. A gauge on the annulus between the 4.5 casing and injection tubing showed the annulus to be pressured at 450psi. I found no violations at this time. |
0875863494 | 2006-06-20 | Salt Water Injection Well | Violations Noted | A 1000 gallon fiberglass pad drain containment tank has been installed. However, the automatic sump pump to empty the tank has not. The system is still inadequate and the ID signs have not been posted. |
0887524896 | 2011-11-03 | Salt Water Injection Well | No Violations | I performed the quarterly UIC test on the annulus and the injection. The well was running. There were no violations at this time. |
0912288490 | 2006-02-23 | Salt Water Injection Well | No Violations | Status check inspection of this salt water disposal well. I spoke with John Firko and asked him to put more pressure (200 psi) on the annulus. The was some pressure but not enough to register on the gauge. He stated that they have a high pressure pump on one of their water trucks that could do the job. Power Gas has also completed some modifications to the containment system which probably should have had prior approval. The changes include 1) segregating ponds 1, 2 and 3 from ponds 4, 5 and 6 by placing a mechanical plug between ponds 3 and 4; 2) constructing a partially curbed concrete pad west of the ponds for use by trucks offloading directly into pond 3; and 3) failing to provide adequate secondary containment around the concrete pad. I told Mr. Firko to contact Tom Tomastik in Columbus to discuss these changes. I will follow up. |
0946906074 | 2010-05-20 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. |
0957279072 | 2017-10-24 | Salt Water Injection Well | No Violations | I found no changes since the last inspection. The UIC facility site has a locked chain link fence. The proper identification is posted. There are no violations at this time. |
0967659162 | 2003-04-17 | Salt Water Injection Well | Violations Noted | NOV follow up with Supervisor Cheslock. No action has been taken to remediate the contamination described on 4/15. No one was in the Power Gas field office during this site visit. The main office in Pittsburgh will be notified of these violations. |
0972881684 | 2009-02-03 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. The new pump system is not operational. The company is still using the old pump and the old injection line. |
1011192924 | 2003-11-18 | Salt Water Injection Well | No Violations | UIC inspection - the system is shut down while prior violations are being corrected - annulus 0, injection 0. |
1022675919 | 2014-09-23 | Salt Water Injection Well | No Violations | There were no violations found at the time. |
1043694193 | 2016-03-31 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1052269105 | 2003-04-28 | Salt Water Injection Well | No Violations | Remediation around the brine injection and storage system has been initiated. A backhoe was removing dead vegetation near the injection well and the storage tank pad had been steam cleaned. According to Paul Craemer with Power Gas, the oil in the brine pits will be skimmed off and the tank pad will be pressure washed again. I will continue to monitor the facility. |
1053997868 | 2003-05-12 | Salt Water Injection Well | No Violations | Follow up inspection. The impacted vegetation has been removed and the soil reseeded and mulched. Power Gas has also started to clean the tank pad and correct the problems with the settling ponds. |
1069159768 | 2010-08-26 | Salt Water Injection Well | No Violations | Quarterly status check inspection found that the annulus pressure had increased since the previous inspection in May. The injection pressure and the annulus pressure were not equalized but I advised Enervest to regularly monitor the pressures. Instead, Enervest decided to schedule a MIT for 8/30 to test the packer. |
1072210076 | 2003-12-22 | Salt Water Injection Well | Violations Noted | Work on the concrete pond walls is approximately 75% complete. Power Gas submitted a proposal to UIC for temporary repair of the system. The proposal was accepted and I am waiting for notification from Power Gas as to when then intend to begin work. The proposal calls for 1) the removal of the three 210 bbl tanks; 2) lining of the containment area around the tanks with clay and a 20 mil liner and 3) resetting two of the 210 tanks inside new containment area. The proposal calls for continued use of the concrete settling ponds. |
1073378290 | 2015-12-29 | Salt Water Injection Well | No Violations | An inspection of the injection well and surface facility found no violations. |
107838081 | 2003-11-25 0:00 | SW | No Violations | |
1078442613 | 2011-03-09 | Salt Water Injection Well | No Violations | On 3/7, Rick Keppler with EnerVest Operating reported a tank overfill inside of the containment dike associated with this system. The overfill occurred when a sump pump inside of the containment dike was left on over the weekend. The estimated loss was less than 20 bbl of oil /brine/fresh. The entire volume was contained and is being returned to the tanks with a vacuum truck and a steam truck. Recovery was initiated on 3/7, continued on 3/8 and 3/9 with an EnerVest vacuum truck, Sutton Pump steam trucks and EnerVest employees. Company response was prompt and effective. |
1094771520 | 2011-05-18 | Salt Water Injection Well | No Violations | I went with Bob Worstall to check pressures on this well. There were no violations at this time. |
1103609446 | 2010-09-14 | Salt Water Injection Well | No Violations | Universal Well Service was on site to complete another MIT. The premixed inhibitor was pumped down the annulus and up through the 2-7/8 tubing. Once inhibitor circulated to surface, the Halliburton R-4 packer was set in tension and the annulus was pressured up to 900 psi. The pressure began to fall immediately. Several more attempts also failed before Universal was released. Enervest now plans to test the casing at 500 intervals in an attempt to locate the leak. |
1126694830 | 2002-06-25 | Salt Water Injection Well | Violations Noted | FOLLOW UP TO NOV # 2154i249 4-24-02 Met with John Firko at the site and informed him that the kill area on the north side of the concrete containment and the spill area on the south side of the concrete containment needed cleaned up and seeded. Also the area around the injection |
1187095046 | 2007-07-31 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations. |
1191071925 | 2004-11-10 | Salt Water Injection Well | No Violations | Status check inspection. |
1199148359 | 2018-02-12 | Salt Water Injection Well | No Violations | I was on location to inspect the UIC well and facility. I found the well not in operation on the day of my inspection. I found no spills or leaks. The proper identification signs are posted. Pressure on the tubing and annulus read zero (0). I contacted Mike Burkhart of Enervest to add pressure to the annulus. Mr. Burkhart stated pressure would be placed on the annulus as soon as possible. Mr. Burkhart stated he would notify me of the date and time. |
1216i19542 | 2001-11-07 | Salt Water Injection Well | No Violations | No violations noted this date. Last inspetion: 09-10-2001 |
1216i1954266 | 2001-11-7 0:00: | SW | No Violations | 1.00 |
1216i45180 | 2000-01-28 | Salt Water Injection Well | No Violations | There was no inspection done this date. The information for the latitude and longitude was recorded at the last inspection and is now being entered. |
1216i451809 | 2000-1-28 0:00: | SW | No Violations | |
1227420643 | 2003-10-30 | Salt Water Injection Well | Violations Noted | Work is continuing to repair the cracks in the concrete settling ponds. Power Gas is still getting bids to repair the tank pad. |
1237215429 | 2009-03-10 | Salt Water Injection Well | No Violations | Completed a mini-MIT on the injection well. Exco provided their treating truck to pressurize the annular space between the 2-3/8 tubing and the 4-1/2 casing. The permitted pressure is 860 psi. Based on the response of the state issued Wica pressure gauge, Exco pressured the well up to 920 psi. After 5 minutes the pressure remained the same. After 15 minutes, the pressure remained at 920 psi. The MIT was a success. A MIT will be completed on the injection line as soon as it is ready. |
1254999488 | 2009-01-15 | Salt Water Injection Well | No Violations | The oil storage portion of the storage system is functional and in operation. The old pump is still in place. North Coast has been notified that a MIT will be required for the new injection line and I have requested a mini-MIT on the packer at the same time. |
1257553124 | 2005-05-31 | Salt Water Injection Well | No Violations | Status check inspection for this salt water disposal well. No violations at this time. I spoke with John Firko and requested that they put at least 200 psi on the annulus in order to show a pressure differential. |
1260215166 | 2005-08-25 | Salt Water Injection Well | No Violations | Status check inspection - no violations at this time. Power Gas is continuing to clean out the settling ponds. The three north ponds are completed with plans to clean out the three south side ponds this fall. Housekeeping is always an issue. |
1261743993 | 2020-7-8 0:00:0 | SW | No Violations | 0.50 |
1263551557 | 2013-06-28 | Salt Water Injection Well | No Violations | There were no violations found at the time of inspection. |
1270188102 | 2007-11-27 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. |
1284409492 | 2010-09-07 | Salt Water Injection Well | No Violations | Whipstock Natural Gas Services was on site to run a new Halliburton R-4 packer on a string of 2-7/8 tubing. Universal Well Service mixed and displaced inhibitor which was pumped down the tubing and returned through the annulus. Once inhibitor circulated to surface, the packer was set in tension, the wellhead was tightened and the MIT began. The planned MIT pressure was 900 psi. At approximately 500 psi, the 4-1/2 casing started leaking above the wellhead and below the top collar. The test was called off and the pressure released. Enervest will present a corrective action plan to repair or replace the leaking casing as soon as possible. |
1284686363 | 2008-11-17 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. The new storage facility is nearing completion. The required containment dike is completed and the eight 210 bbl tanks have been placed inside. The tanks are being connected and the pumphouse will be reconfigured prior to placing the new system in operation. The old concrete storage facility will be steam cleaned and pumped out before crushing and backfilling with limestone. |
1285704532 | 2010-09-20 | Salt Water Injection Well | No Violations | After replacing a leaking joint of 4-1/2 casing and several joints of leaking 2-7/8 tubing, Universal Well Service was on site to attempt the third mechanical integrity test. Universal circulated 1650 gallons of inhibitor down the annulus and up the tubing. Whipstock then set the rebuilt Halliburton R-4 packer in tension at 3784. Universal pressured up on the annulus to 900 psi. After five minutes the pressure was 895 psi and after 15 minutes the pressure was 875 psi. The pressure loss of 25 psi was within the allowable pressure loss and the MIT passed. |
1323575308 | 2012-08-20 | Salt Water Injection Well | No Violations | My inspection of the well site and injection facility was accompanied by another inspector, Tom Hill.
There were no violations at the time of inspection. |
1330401005 | 2008-02-21 | Salt Water Injection Well | No Violations | Quarterly status check inspection of this salt water injection well found no violations at this time. North Coast is still in the process of cleaning out half of the concrete holding ponds. |
1357880468 | 2017-09-25 | Salt Water Injection Well | No Violations | Status check inspection of this salt water disposal well. I was on location with DOGRM District Supervisor Steve Ochs to conduct quarterly status checks for the UIC Program. The 2.875 injection tubing was currently on vacuum. The pressure on the annular gauge between the 2.75 injection tubing and 4.5 casing indicated a pressure of 0psi. The plug on the needle valve was removed, the valve was opened, and it was found that the annulus was on vacuum. A call was made to Mike Burkhardt (Enervest) to inform him of the issue. He said he would get a pump truck to location and pressure up on the annulus to determine if the tubing or packer is leaking. He will inform the Division when the pressure test will occur so it may be witnessed by a Division Inspector. We will wait for notification. |
1380650490 | 2013-09-30 | Salt Water Injection Well | No Violations | My inspection of the well and injection facility found no violations. |
1396556958 | 2014-03-28 | Salt Water Injection Well | No Violations | The were no violations at the time of inspection. |
1410088376 | 2009-08-27 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. |
1418651353 | 2014-10-16 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. Tubing and casing pressures indicated mechanical integrity. There were no violations found at the time. |
1498049669 | 2017-06-21 | Salt Water Injection Well | No Violations | Quarterly status check inspection of this saltwater disposal well. The pump is currently off and there is no pressure indicated on the injection tubing. A gauge at the wellhead indicates and annular pressure of 240psi. The pressure chart in the pump house indicates the well has been operating at an injection pressure of 140psi. The facility is in good order. I found no violations at this time. |
1511185166 | 2017-11-20 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well and facility. There is an identification sign posted. There are no violations at this time. |
1520430923 | 2018-03-07 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well. There proper identification sign is posted. There are no violations at this time. |
1520869353 | 2011-02-15 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. |
1523630720 | 2010-03-18 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. Note the change in operator from EXCO-North Coast to Enervest Operating. |
1533840741 | 2018-08-09 | Salt Water Injection Well | No Violations | I found the injection well not operating on the day of my inspection. An identification sign is posted at the tank battery. I observed no leaks or spills. |
1542894103 | 2016-09-01 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1544845254 | 2007-02-08 | Salt Water Injection Well | No Violations | Quarterly inspection found no violations at this time. |
1556110040 | 2019-4-24 0:00: | SW | No Violations | |
1561467585 | 2019-6-25 0:00: | SW | No Violations | 1.10 |
1585668921 | 2020-3-31 0:00: | SW | No Violations | 1.00 |
1586641079 | 2004-05-10 | Salt Water Injection Well | No Violations | Status check inspection of this salt water disposal well. Power Gas is working on the surface facility and should have the well back in operation later this summer. No other violations at this time. |
1634010171 | 2009-03-19 | Salt Water Injection Well | No Violations | North Coast called and requested a time to complete a MIT on the new injection line from the new pump house to the well. The bypass was opened and fresh water was pumped through the line to purge any trapped air. At 10:23, the line was pressured to 1030 psi. After five minutes the pressure declined to 1020 psi. After ten minutes the pressure was at 1010 psi and after 15 minutes, the pressure was still at 1010 psi. The injection line passed the MIT. |
1664294016 | 2018-03-13 | Salt Water Injection Well | No Violations | I was on location to re-inspect the injection well since Enervest added pressure on the annulus on March 1, 2018. There are no violations at this time. |
1678209742 | 2003-11-05 | Salt Water Injection Well | Violations Noted | Work is continuing on the concrete pond wall repair. |
1710430838 | 2017-09-29 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well. There is a locked chain link fence around the tank battery. An identification sign is posted. There are no violations at this time. |
1715775605 | 2010-07-20 | Salt Water Injection Well | No Violations | 150 bbl of fresh water is being used every day to flush and recover brine from inside of the containment area. |
1778000207 | 2005-02-17 | Salt Water Injection Well | No Violations | Status check inspection of this salt water disposal well and storage system. Housekeeping is again becoming a problem. Will speek to the operator about correcting these issues before they become a violation. |
1791061626 | 2003-05-22 | Salt Water Injection Well | No Violations | The pollution violation remediation is progressing very slowly. No addition enforcement action is recommended as long as progress is being made. |
1817368960 | 2008-12-15 | Salt Water Injection Well | No Violations | Met on site with Joe Shepard to discuss closing the old brine storage system. They intend to steam clean each of the six holding ponds, pump out the accumulated water with their vac truck and collapse the western side wall and the center support walls. |
1820024966 | 2006-08-30 | Salt Water Injection Well | No Violations | Quarterly status check inspection. No violations at this time. |
1881535261 | 2008-08-19 | Salt Water Injection Well | No Violations | Quarterly status check inspection found no violations at this time. The well continues to operate below the maximum allowable injection pressure. |
1894717817 | 2017-12-12 | Salt Water Injection Well | No Violations | I found the injection and facility in good repair on the day of my inspection. I observed no leaks or spills. An identification sign is posted at the facility. There are no violations at this time. |
1914882254 | 2015-03-30 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1915212397 | 2020-4-7 0:00:0 | SW | No Violations | 0.70 |
1978960487 | 2005-11-30 | Salt Water Injection Well | No Violations | Status check inspection of this salt water injection well. No violations at this time. |
1987202711 | 2008-12-23 | Salt Water Injection Well | No Violations | Demolition work is completed and backfilling will begin after the holiday. The new containment system is nearly complete. |
2026253589 | 2018-06-25 | Salt Water Injection Well | No Violations | I found the injection well not in operation on the day of my inspection. An identification sign is posted. I observed no leaks or spills. There are no violations at this time. |
2057717846 | 2004-02-12 | Salt Water Injection Well | Violations Noted | Work has not begun on the temporary repair proposed and accepted by MRM on December 3, 2003. According to John Firko work will begin as soon as the weather permits. 120# injection, 0# annulus. |
2063638614 | 2007-03-01 | Salt Water Injection Well | No Violations | The requested changes and additions to the well and injection system have been completed. Thank you. |
2093089236 | 2010-08-30 | Salt Water Injection Well | No Violations | The quarterly inspection of this injection well indicated possible packer failure. Enervest decided to complete a mechanical integrity test to verify the packer integrity. The test was attempted several times and the pressure loss exceeded the allowable 5% over 15 minutes every time. Enervest will schedule a service rig to unseat and remove the packer. MRM records indicate that this Halliburton R-4 packer was set in tension on 12/7/1994. |
2096990412 | 2008-12-22 | Salt Water Injection Well | No Violations | Less Contracting was on site with two track hoes and a wrecking ball to start demolition of the concrete containment ponds. Demolition should be compelted tomorrow with backfilling to begin immediately. |
2110956842 | 2008-10-31 | Salt Water Injection Well | No Violations | The containment area for the disposal well is being moved to a new location on the North Coast property. The earthen containment dike has been built and finish work is scheduled for next week. The old containment area will be pressure washed, cleaned out and crushed before backfilling with stone. |
2111244723 | 2003-04-15 | Salt Water Injection Well | Violations Noted | UIC Inspection - the areas near the well head and the storage tanks have experienced vegataion kills from brine spills. The storage area and offloading areas are saturated with oil. The concrete retention ponds have been overfilled causing impact outside of the retention area. A brine release at the wellhead has impacted an area several hundred feet long and several feet wide. The entire facility needs to be remediated and operated properly. |
2154i128 | 2002-4-24 0:00: | SW | No Violations | 0.50 |
2154i249 | 2002-6-25 0:00: | SW | No Violations | 1.00 |
2154i324 | 2002-7-29 0:00: | SW | No Violations | 1.00 |
2154i393 | 2002-8-21 0:00: | SW | No Violations | 1.00 |
256704006 | 2003-9-25 0:00: | SW | No Violations | |
299591256 | 2010-9-10 0:00: | SW | No Violations | |
347784271 | 2010-7-15 0:00: | SW | No Violations | |
405288274 | 2009-5-12 0:00: | SW | No Violations | |
409177066 | 2010-12-16 0:00 | SW | No Violations | |
429069536 | 2003-6-17 0:00: | SW | No Violations | |
438112027 | 2008-5-14 0:00: | SW | No Violations | |
478048131 | 2006-12-11 0:00 | SW | No Violations | |
498947847 | 2019-3-13 0:00: | SW | No Violations | 0.40 |
519189261 | 2004-5-20 0:00: | SW | No Violations | |
560783797 | 2009-11-13 0:00 | SW | No Violations | |
604454622 | 2008-12-17 0:00 | SW | No Violations | |
6379055 | 2002-2-28 0:00: | SW | No Violations | 0.50 |
675022396 | 2011-5-18 0:00: | SW | No Violations | |
733588748 | 2019-2-1 0:00:0 | SW | No Violations | |
763519043 | 2011-8-4 0:00:0 | SW | No Violations | |
786583713 | 2010-9-2 0:00:0 | SW | No Violations | |
819122446 | 2018-4-2 0:00:0 | SW | No Violations | 0.50 |
827659748 | 2004-8-12 0:00: | SW | No Violations | |
846187455 | 2013-12-30 0:00 | SW | No Violations | |
862400859 | 2016-5-12 0:00: | SW | No Violations | 0.50 |
887524896 | 2011-11-3 0:00: | SW | No Violations | |
946906074 | 2010-5-20 0:00: | SW | No Violations | |
957279072 | 2017-10-24 0:00 | SW | No Violations | 0.50 |
972881684 | 2009-2-3 0:00:0 | SW | No Violations | |
UIC1023 | 1990-10-1 0:00: | SW | No Violations | |
UIC1818 | 2000-1-27 0:00: | SW | No Violations | |
UIC249 | 1987-6-3 0:00:0 | SW | No Violations | |
UIC350 | 1987-9-14 0:00: | SW | No Violations | |
UIC938 | 1990-6-18 0:00: | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
002154i249 | US-OH-122079 | 2002-06-27 | Pollution/Contamination | |
002154i324 | US-OH-122093 | 2002-07-30 | Pollution/Contamination | |
002154i393 | US-OH-121996 | 2002-08-21 | Pollution/Contamination | |
0183656593 | US-OH-118342 | 2006-05-03 | Permit not displayed | |
0225173830 | US-OH-122247 | 2003-09-22 | Pollution/Contamination | |
0225173830 | US-OH-122248 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
0256704006 | US-OH-122644 | 2003-09-22 | Pollution/Contamination | |
0256704006 | US-OH-122645 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
0341063392 | US-OH-123558 | 2003-09-22 | Pollution/Contamination | |
0341063392 | US-OH-123559 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
0429069536 | US-OH-124586 | 2003-06-30 | Pollution/Contamination | |
0429069536 | US-OH-124587 | 2003-06-30 | Pits not liquid tight/Improper construction or use | |
0434191908 | US-OH-124659 | 2003-09-22 | Pollution/Contamination | |
0434191908 | US-OH-124660 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
0474948021 | US-OH-125111 | 2003-06-30 | Pollution/Contamination | |
0474948021 | US-OH-125112 | 2003-06-30 | Pits not liquid tight/Improper construction or use | |
0478048131 | US-OH-125200 | 2006-05-03 | Permit not displayed | |
0690913315 | US-OH-127812 | 2003-09-22 | Pollution/Contamination | |
0690913315 | US-OH-127813 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
0714657768 | US-OH-128112 | 2003-09-22 | Pollution/Contamination | |
0714657768 | US-OH-128113 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
0875863494 | US-OH-129970 | 2006-05-03 | Permit not displayed | |
0967659162 | US-OH-131101 | 2003-04-21 | Pollution/Contamination | |
1072210076 | US-OH-101504 | 2003-09-22 | Pollution/Contamination | |
1072210076 | US-OH-101505 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
1126694830 | US-OH-103198 | 2002-06-27 | Pollution/Contamination | |
1227420643 | US-OH-106123 | 2003-09-22 | Pollution/Contamination | |
1227420643 | US-OH-106124 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
1678209742 | US-OH-116610 | 2003-09-22 | Pollution/Contamination | |
1678209742 | US-OH-116611 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
2057717846 | US-OH-120955 | 2003-09-22 | Pollution/Contamination | |
2057717846 | US-OH-120956 | 2003-09-22 | Failure to repair pits/Unlawful use of pits | |
2111244723 | US-OH-121585 | 2003-04-21 | Pollution/Contamination |
For data sources see[9]