34-133-23405

Well Details

Well ID: 34-133-23405
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Mantua Township
Operator Name: CEDAR VALLEY ENERGY INC
Well Pad ID:
Farm/Lease Name: FUGMAN-YANEGA UNIT
License Status: Producing
License Date: 1985-07-26
Spud Date: 1985-09-17
Spud Drilling Contractor: NANCY DRLG
Final Drill Date: 1985-09-23
Well Total Depth: 4205.00 ft
Configuration: Vertical
Latitude: 41.340000
Longitude: -81.280000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1985-07-26 1553 NORTH AMERICAN PROD CO GeoDate 7/26/85
Oil and Gas 1985-07-26 Issued Date 7/26/85 Expired Date 7/26/86 Acres 0085930 Tool Type RTF Proposed Formation CLINTON Proposed Depth 04205 Proposed Drill Depth 04205
Original Spud 1985-09-17
Completed 1985-09-23
Reached Total Depth 1985-09-23
Completion Report Received 1985-10-17
Construction Permit Expires 1986-07-26
Change of Owner 2006-05-15 Operator changed from 1553, NORTH AMERICAN PROD CO to 2037, CEDAR VALLEY ENERGY INC
Last Compliance Report 2017-03-16
Record Last Modified 2017-03-16

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3986 4104 0
3986 4104 0
2006-09-11 4014 4056 40
4014 4056 40
3986 4104 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 81650 Gal 50000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 EAGLE INVESTMENT INC 2826.00 486.00 61
1986 NORTH AMERICAN PROD CO 10978.00 1054.00 331
1987 NORTH AMERICAN PROD CO 4794.00 782.00 112
1988 NORTH AMERICAN PROD CO 4855.00 448.00 339
1989 NORTH AMERICAN PROD CO 3794.00 504.00 320
1990 NORTH AMERICAN PROD CO 3483.00 402.00 348
1992 NORTH AMERICAN PROD CO 2446.00 378.00 365
1993 NORTH AMERICAN PROD CO 1747.00 189.00 296
1994 NORTH AMERICAN PROD CO 2168.00 168.00 318
1995 NORTH AMERICAN PROD CO 1641.00 172.00 299
1996 NORTH AMERICAN PROD CO 1308.00 131.00 323
1997 NORTH AMERICAN PROD CO 933.00 350.00 365
1998 NORTH AMERICAN PROD CO 1136.00 252.00 365
2000 CEDAR VALLEY ENERGY INC 1052.00 177.00 365
2001 CEDAR VALLEY ENERGY INC 898.00 183.00 365
2002 CEDAR VALLEY ENERGY INC 998.00 138.00 365
2003 CEDAR VALLEY ENERGY INC 902.00 183.00 364
2004 CEDAR VALLEY ENERGY INC 792.00 63.00 365
2005 CEDAR VALLEY ENERGY INC 1379.00 99.00 365
2006 CEDAR VALLEY ENERGY INC 1318.00 116.00 365
2007 CEDAR VALLEY ENERGY INC 1505.00 156.00 365
2008 CEDAR VALLEY ENERGY INC 1173.00 0.00 365
2009 CEDAR VALLEY ENERGY INC 1295.00 82.00 365
2010 CEDAR VALLEY ENERGY INC 1227.00 86.00 365
2011 CEDAR VALLEY ENERGY INC 1324.00 114.00 365
2012 CEDAR VALLEY ENERGY INC 1127.00 97.00 366
2013 CEDAR VALLEY ENERGY INC 1633.00 0.00 365
2014 CEDAR VALLEY ENERGY INC 1488.00 153.00 365
2015 CEDAR VALLEY ENERGY INC 1906.00 88.00 365
2016 CEDAR VALLEY ENERGY INC 1433.00 51.00 365
2017 CEDAR VALLEY ENERGY INC 1160.00 70.00 365
2018 CEDAR VALLEY ENERGY INC 984.00 53.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 EAGLE INVESTMENT INC Brine 361 61
1986 NORTH AMERICAN PROD CO Brine 610 331
1987 NORTH AMERICAN PROD CO Brine 140 112
1988 NORTH AMERICAN PROD CO Brine 123 339
1989 NORTH AMERICAN PROD CO Brine 84 320
1990 NORTH AMERICAN PROD CO Brine 115 348
1992 NORTH AMERICAN PROD CO Brine 69 365
1993 NORTH AMERICAN PROD CO Brine 29 296
1994 NORTH AMERICAN PROD CO Brine 39 318
1995 NORTH AMERICAN PROD CO Brine 70 299
1996 NORTH AMERICAN PROD CO Brine 39 323
1997 NORTH AMERICAN PROD CO Brine 48 365
1998 NORTH AMERICAN PROD CO Brine 94 365
2000 CEDAR VALLEY ENERGY INC Brine 63 365
2001 CEDAR VALLEY ENERGY INC Brine 76 365
2002 CEDAR VALLEY ENERGY INC Brine 39 365
2003 CEDAR VALLEY ENERGY INC Brine 71 364
2004 CEDAR VALLEY ENERGY INC Brine 33 365
2005 CEDAR VALLEY ENERGY INC Brine 0 365
2006 CEDAR VALLEY ENERGY INC Brine 103 365
2007 CEDAR VALLEY ENERGY INC Brine 22 365
2008 CEDAR VALLEY ENERGY INC Brine 81 365
2009 CEDAR VALLEY ENERGY INC Brine 0 365
2010 CEDAR VALLEY ENERGY INC Brine 139 365
2011 CEDAR VALLEY ENERGY INC Brine 75 365
2012 CEDAR VALLEY ENERGY INC Brine 90 366
2013 CEDAR VALLEY ENERGY INC Brine 80 365
2014 CEDAR VALLEY ENERGY INC Brine 150 365
2015 CEDAR VALLEY ENERGY INC Brine 80 365
2016 CEDAR VALLEY ENERGY INC Brine 69 365
2017 CEDAR VALLEY ENERGY INC Brine 29 365
2018 CEDAR VALLEY ENERGY INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1093118925 2017-1-19 0:00: TD No Violations 0.40
-1649753715 2005-9-6 0:00:0 AD No Violations
-1894707428 2010-8-26 0:00: PW No Violations
-681129968 2010-4-21 0:00: AD No Violations
0000PL5979 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0418570940 2012-05-21 Production Wells No Violations I was on location today to inspect the well due to, two adjacent water well complaints. I had the company expose the annulus and asses the pressure. I meet with Tim Cosma from Cedar Valley. Tim exposed the annulus and it was found that the annulus was open. Three weeks ago the operator repaired a flow line leak by clamping it. The operator also tripped out the old pump and replaced it. Adjacent landowners are claiming that there water issues started at the same time. The well has a pumping unit on it. The area around the well has been affected by the work over and the repair of the line. Operator will need to reclaim affected area. The tank battery was in good repair. The tank batterys inventory was: two 210 barrel production tanks and two vertical separators. Tank battery was fenced and the identification sign was posted.
0681129968 2010-04-21 Annular Disposal No Violations Columbus requested this inspection to determine the current annular disposal status. Annular disposal does not appear to be used at this time.
1093118925 2017-01-19 Temporary Abandoned Annular Disposal No Violations I was on location to inspect this well for the use of annular disposal. My inspection found the wellhead equipped with an electric-powered pumping unit. The wellhead and unit are fenced and the required ID is posted on the fencing. A gauge indicates 76psi on the production tubing and there is a domestic tap on the 4.5 production casing. This well produces to a diked tank battery to the south containing two (2) 210 barrel tanks, two (2) vertical separators, and the associated meter run. The tank battery is fenced and locked, and the required ID is posted on a tank. I found no evidence of annular disposal being used at this time. No violations.
1190353321 2010-04-06 Production Wells No Violations The area impacted by the salesline leak still needs to be seeded and mulched before the case is closed.
1270146520 2010-04-01 Production Wells No Violations I inspected the yard area. Top soil has been spread over the area of the spill. It will be around 2 weeks before Cedar Valley will plant the pine tree and seed the spill area. This complaint continues.
1372859841 2010-03-31 Production Wells No Violations I received a call from Jay Cheslock at 11:43AM about a complaint from Mr. And Mrs. Tom Zenkewicz of 12777 Chamberlain road. The complaint(#2641) was a oil spill in the southeast corner of there front yard. I called Tim Cosma-Field Supt. Cedar Valley (330-853-9565). He was aware of the spill and headed that way. I arrived on the scene at 1:38PM. Tim and I met and looked over the spill. The spill was approximately 1 quart of oil. Bruderly Excavating was called and will be on the location shortly. Bruderly arrived with the trackhoe and proceeded to dig up the spill area and dumped the contaminated soil in his truck. There were 2 lines in the ground. One line was the production line for well number 3405 and the other was a dead line from the other well of 3399 across the road. A patch was installed on the 2 steel dead line. Tim stated that they would flush the old line at a later date. The hole was filled back in. The owners also talked about replacing a pine tree that was 4 feet to the southeast of the leak. Tim stated that they would do that. He wanted to ground to settle out before replacing the pine tree. Top soil will be hauled in tomorrow. This complaint continues.
1649753715 2005-09-06 Annular Disposal No Violations No annular disposal at this site at this time.
1894707428 2010-08-26 Production Wells No Violations The area affected by the salesline leak is restored and grass is growing. The case is closed.
418570940 2012-5-21 0:00: PW No Violations
PL5979 PL No Violations

For data sources see[9]

References