34-133-24060

Well Details

Well ID: 34-133-24060
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Randolph Township
Operator Name: PEP DRILLING LLC
Well Pad ID:
Farm/Lease Name: EBIE
License Status: Producing
License Date: 1996-05-08
Spud Date: 1996-06-11
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 1996-06-20
Well Total Depth: 7490.00 ft
Configuration: Vertical
Latitude: 41.010000
Longitude: -81.200000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1996-05-08 1198 PIPES PURSIE E GeoDate 5/8/96
Oil and Gas 1996-05-08 Issued Date 5/8/96 Expired Date 5/8/97 Acres 0040000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth 07490 Proposed Drill Depth 07490
Original Spud 1996-06-11
Completed 1996-06-20
Reached Total Depth 1996-06-20
Completion Report Received 1996-12-05
Construction Permit Expires 1997-05-08
Change of Owner 2016-03-04 Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 7348 7433 153
7348 7433 153
7348 7433 153

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 1000 Gal 0 FRAC W/1500 BW & 300 SX SAND
H2O 0 1500 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1996 PIPES PURSIE E 4493.00 5284.00 173
1997 PIPES PURSIE E 14973.00 824.00 365
1998 PIPES PURSIE E 9559.00 3934.00 365
1999 PIPES PURSIE E 8492.00 3955.00 365
2000 PIPES PURSIE E 5337.00 1723.00 365
2001 PIPES PURSIE E 3250.00 963.00 365
2002 PIPES PURSIE E 2555.00 116.00 365
2003 PIPES PURSIE E 3605.00 1955.00 365
2004 PIPES PURSIE E 3457.00 1375.00 365
2005 PIPES PURSIE E 2903.00 1217.00 365
2006 PIPES PURSIE E 3481.00 1108.00 365
2007 PIPES PURSIE E 3572.00 805.00 365
2008 PIPES PURSIE E 2928.00 716.00 365
2009 PIPES PURSIE E 2272.00 703.00 365
2010 PIPES PURSIE E 4038.00 710.00 365
2011 PIPES PURSIE E 2895.00 501.00 365
2012 PIPES PURSIE E 3075.00 426.00 366
2013 PIPES PURSIE E 3843.00 493.00 365
2014 PIPES PURSIE E 3457.00 310.00 365
2016 PEP DRILLING LLC 1101.00 115.00 365
2017 PEP DRILLING LLC 1016.00 38.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1996 PIPES PURSIE E Brine 2038 173
1997 PIPES PURSIE E Brine 6584 365
1998 PIPES PURSIE E Brine 4968 365
1999 PIPES PURSIE E Brine 690 365
2000 PIPES PURSIE E Brine 4156 365
2001 PIPES PURSIE E Brine 3757 365
2002 PIPES PURSIE E Brine 4087 365
2003 PIPES PURSIE E Brine 5550 365
2004 PIPES PURSIE E Brine 4848 365
2005 PIPES PURSIE E Brine 4636 365
2006 PIPES PURSIE E Brine 4957 365
2007 PIPES PURSIE E Brine 4852 365
2008 PIPES PURSIE E Brine 6185 365
2009 PIPES PURSIE E Brine 5006 365
2010 PIPES PURSIE E Brine 6552 365
2011 PIPES PURSIE E Brine 5270 365
2012 PIPES PURSIE E Brine 5696 366
2013 PIPES PURSIE E Brine 5058 365
2014 PIPES PURSIE E Brine 4475 365
2016 PEP DRILLING LLC Brine 0 365
2017 PEP DRILLING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-900319584 2018-6-29 0:00: UP No Violations 0.40
0436060709 2009-09-29 Production Wells No Violations The wells that were effected: Abie #4, API 4060, Abie #5, API 4064.

Randolph Co. Fire Dept. received a call from a landowner across the street at around 10:30 AM, 9/29/09. The landowner(Craig Klodt) later stated that he had heard it thundering earlier in the morning. The pumper was called, Steve Pero. Steve called Mark Smith. The tank battery was owned by PEP Company. Bob Whorstall called me, Carl Roberts at 12:30PM to make the call to investigate the incident. Bob was in Columbus for a meeting. I arrived on the location at 1:00PM. The fire department had extinguished the fire with foam. There were 4 stock tanks going north to south. Lightening had hit the 3rd stock tank. The stock tank was launched some 120 feet southeast of the tank battery area. A chain reaction occurred to the other 2 stock tanks and the separator. The separator ball valve failed and the sales line gas came back in and set the separator on fire. There were 15 barrels of fluid that was released from inside the 3rd stock tank that ended up inside the dike. The whole 15 barrels were recovered. The clean up started immediately. There were 2 water trunks and a track hoe.

0900319584 2018-06-29 UrbanProduction Wells No Violations Status check inspection of this Rose Run Sandstone well. My inspection found the wellhead equipped with 2.375 rods and tubing and operating with the aid of an electric powered pumping unit. This well produces to a diked tank battery to the south and is shared by the Ebie #s 2 & 5 (PN#s 3208 & 4064). This well and the #5 produce through a horizontal separator and into three (3) 210 barrel tanks. The chart at the meter run indicates a differential production pressure of 70psi. The required ID is posted at the wellhead and at the tank battery. This well was drilled prior to the implementation of HB 278, and due to its remote location in a cornfield and the presence of a locked access gate, urban requirements will not be enforced at this time. No violations.
1504945738 2003-11-05 Production Wells No Violations Status check inspection - no violations at this time.
436060709 2009-9-29 0:00: PW No Violations
iDIAN00038 1998-08-31 Preliminary Restoration No Violations
iDIAN000387 1998-8-31 0:00: PL No Violations

For data sources see[9]