X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-133-24263

Well Details

Well ID: 34-133-24263
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Atwater Township
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: DRAKULICH UNIT
License Status: Producing
License Date: 2001-07-31
Spud Date: 2001-09-18
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2001-09-24
Well Total Depth: 4869.00 ft
Configuration: Vertical
Latitude: 41.040000
Longitude: -81.130000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2001-07-31 2050 ORION PETRO CORP Proposed Formation CLINTON Issued Date 7/31/01 Expired Date 7/31/02 6:00:00 AM
Original Spud 2001-09-18 RBDMS Rec
Completed 2001-09-24 RBDMS Rec
Reached Total Depth 2001-09-24 RBDMS Rec
Completion Report Received 2001-11-19 RBDMS Rec
Construction Permit Expires 2002-07-31 RBDMS Rec
Change of Owner 2016-10-07 Operator changed from 2050, ORION PETRO CORP to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-01-16 4684 4772 42
4684 4772 42
4684 4772 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1333 Bbl 20000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 ORION PETRO CORP 0.00 1059.00 71
2002 ORION PETRO CORP 11180.00 2542.00 365
2003 ORION PETRO CORP 5682.00 1377.00 365
2004 ORION PETRO CORP 4516.00 976.00 365
2005 ORION PETRO CORP 3602.00 783.00 365
2006 ORION PETRO CORP 3426.00 724.00 365
2007 ORION PETRO CORP 3278.00 609.00 365
2008 ORION PETRO CORP 2692.00 521.00 365
2009 ORION PETRO CORP 2245.00 511.00 365
2010 ORION PETRO CORP 2544.00 408.00 0
2011 ORION PETRO CORP 2093.00 454.00 0
2012 ORION PETRO CORP 2466.00 354.00 366
2014 ORION PETRO CORP 1736.00 354.00 365
2015 ORION PETRO CORP 1598.00 263.00 365
2016 ORION PETRO CORP 1203.00 272.00 273
2017 PIN OAK ENERGY PARTNERS LLC 1557.00 288.00 365
2018 PIN OAK ENERGY PARTNERS LLC 1591.00 256.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 ORION PETRO CORP Brine 1477 71
2002 ORION PETRO CORP Brine 657 365
2003 ORION PETRO CORP Brine 240 365
2004 ORION PETRO CORP Brine 150 365
2005 ORION PETRO CORP Brine 81 365
2006 ORION PETRO CORP Brine 135 365
2007 ORION PETRO CORP Brine 38 365
2008 ORION PETRO CORP Brine 100 365
2009 ORION PETRO CORP Brine 70 365
2010 ORION PETRO CORP Brine 85 0
2011 ORION PETRO CORP Brine 60
2012 ORION PETRO CORP Brine 33 366
2014 ORION PETRO CORP Brine 25 365
2015 ORION PETRO CORP Brine 35 365
2016 PIN OAK ENERGY PARTNERS LLC Brine 0 365
2017 PIN OAK ENERGY PARTNERS LLC Brine 50 365
2018 PIN OAK ENERGY PARTNERS LLC Brine 37 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0001216i43 2001-10-10 Production Wells No Violations Pits partially closed. Service rig on site swabbing into a frac tank.
1216i43 2001-10-10 0:00 PW No Violations 0.50
1353465590 2018-02-09 Production Wells No Violations Status check inspection of this Clinton Sandstone well. My inspection found the wellhead equipped with 2.375 rods and tubing and operating with the aid of a natural gas powered pumping unit. This well produces to a diked tank battery to the southwest and is shared with the Hardway #1 (PN#24262). The battery contains two (2) 210 barrel tanks, two (2) 50 barrel tanks, and two (2) horizontal separators. A chart at the separator indicates a differential production pressure of 50psi. The required ID is posted at the tank battery. No violations.

For data sources see[9]