34-133-24355

Well Details

Well ID: 34-133-24355
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Ravenna Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: GILLY
License Status: Producing
License Date: 2007-12-21
Spud Date: 2008-05-28
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2008-06-03
Well Total Depth: 4652.00 ft
Configuration: Directional
Latitude: 41.160000
Longitude: -81.210000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-12-21 Proposed Formations:CLINTON/MEDINA, Issued Date:12/21/2007, Expired Date:12/20/2008 6:00:00 AM, Drilling unit acres:41.03, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2007-12-28 CORRECTION TO SURFACE FOOTAGE, SHOULD BE "235'SL & 1500'EL OF LOT 24".
Reached Total Depth 2008-06-03
Construction Permit Expires 2008-12-20
Completion Report Received 2008-12-26
Correction to Well 2009-03-20 AS DRILLED SURVEY CORRECTION TO TARGET INFORMATION: FOOTAGE= 235'SL & 1500'EL OF LOT 24; X= 2,353,130; Y= 547,335.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-01-29 4360 4460 58
4360 4460 58
4360 4460 58

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 165140 Gal 0 2-STAGE FRAC; ONLY A SINGLE FRAC VOLUME OF WATER REPORTED… NO TREATMENT OR RESERVOIR PRESSURES WERE REPORTED

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BECK ENERGY CORPORATION 656.00 954.00 0
2009 BECK ENERGY CORPORATION 726.00 1260.00 365
2010 BECK ENERGY CORPORATION 509.00 725.00 365
2011 BECK ENERGY CORPORATION 143.00 533.00 365
2012 BECK ENERGY CORPORATION 113.00 532.00 366
2013 BECK ENERGY CORPORATION 135.00 354.00 365
2014 BECK ENERGY CORPORATION 18.00 357.00 365
2015 BECK ENERGY CORPORATION 3217.00 798.00 365
2016 BECK ENERGY CORPORATION 9849.00 616.00 365
2017 BECK ENERGY CORPORATION 11954.00 527.00 365
2018 BECK ENERGY CORPORATION 12399.00 488.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BECK ENERGY CORPORATION Brine 257
2009 BECK ENERGY CORPORATION Brine 121 365
2010 BECK ENERGY CORPORATION Brine 70 365
2011 BECK ENERGY CORPORATION Brine 70 365
2012 BECK ENERGY CORPORATION Brine 0 366
2013 BECK ENERGY CORPORATION Brine 70 365
2014 BECK ENERGY CORPORATION Brine 20 365
2015 BECK ENERGY CORPORATION Brine 410 365
2016 BECK ENERGY CORPORATION Brine 210 365
2017 BECK ENERGY CORPORATION Brine 150 365
2018 BECK ENERGY CORPORATION Brine 75 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-143541187 2008-5-28 0:00: DD No Violations
-185886875 2009-9-16 0:00: PL No Violations
-1997893887 2008-6-6 0:00:0 DD No Violations
-2005483572 2008-8-25 0:00: PW No Violations
-266950272 2008-6-2 0:00:0 DD No Violations
0143541187 2008-05-28 Drill / Deepen / Reopen No Violations Wildcat has set conductor casing and will resume drilling soon. The pits are lined and fenced. No violations at this time.
0166151463 2018-04-19 UrbanProduction Wells No Violations Status check inspection of this Clinton Sandstone well. My inspection found the wellhead fenced, screened, and locked. The well is equipped with 2.375 rods and tubing and operating with the aid of an electric powered pumping unit. A Murphy Switch gauge on the flow line indicates a pressure of 110psi. There is a domestic tap and meter, equipped with a line heater, on the 4.5 production casing port charged at 12.5psi. This well produces to a diked tank battery on location that is fenced, screened, and locked. The battery contains two (2) 140 barrel tanks, two (2) 35 barrel poly tanks, and a horizontal separator. The tank vents are plumbed to a 42 gallon charcoal filter and the stack is equipped with a low pressure relief valve. The chart at the separator indicates a differential production pressure of 50psi and there is a Dominion ROOTS meter run in the battery. The required ID is posted at the wellhead and at the tank battery. No violations.
0185886875 2009-09-16 Preliminary Restoration No Violations Preliminary restoration is approved.
0266950272 2008-06-02 Drill / Deepen / Reopen No Violations Wildcat is drilling ahead and should reach TD later today. The pits are lined and fenced but are full. The rig did not encounter water in the Newburg as expected. Pander Trucking has been contacted and is sending a water truck to remove several loads from the pits.
1213752616 2008-06-04 Drill / Deepen / Reopen No Violations Wildcat is moving off location. The drilling pits are very full and need to be pumped down soon. This information was given to Beck.
1363584982 2008-05-22 Drill / Deepen / Reopen No Violations Palmer Excavating is on site building the drilling location. The permit was not posted and Beck was notified to post the permit immediately.
1637379258 2008-10-27 Production Wells No Violations The well is in production and the required fencing and ID are up. Preliminary restoration will be approved after the vegetation has established.
166151463 2018-4-19 0:00: UP No Violations 0.60
1965406532 2008-08-14 Production Wells Violations Noted Status check inspection found that the well was on line without the required security fencing installed. I called David Beck and ordered the well shut in immediately and not turned back on until the fence was installed.
1997893887 2008-06-06 Drill / Deepen / Reopen No Violations Ray Pander Trucking is on site to pump down the drilling pits.
2005483572 2008-08-25 Production Wells No Violations A crew was on site today to finish installing the required fencing around the wellhead and the tank battery. Once completed the well can be turned on again.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1965406532 US-OH-119862 2008-08-25 General Safety

For data sources see[9]