X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-133-24404

Well Details

Well ID: 34-133-24404
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Randolph Township
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: M & L WOHLWEND
License Status: Producing
License Date: 2010-12-02
Spud Date: 2010-12-01
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2010-12-19
Well Total Depth: 7080.00 ft
Configuration: Vertical
Latitude: 41.040000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-12-02 Proposed Formations:TRENTON THRU KNOX, Issued Date:12/2/2010, Expired Date:12/1/2012 12:00:00 PM, Drilling unit acres:160, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-12-19
Completion Report Received 2011-01-27
Correction to Well 2011-03-18 UNIT SIZE DECREASED TO 130.94 ACRES.
Correction to Well 2011-09-16 UNIT SIZE DECREASED TO 40 ACRES.
Construction Permit Expires 2011-12-02
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-06-06 6950 6958 36
2011-06-06 6924 6928 20
6924 6928 20
6950 6958 36
6924 6928 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-01-20 ACID 15 2000 Gal 0 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 M & M ROYALTY LTD 0.00 0.00 0
2011 M & M ROYALTY LTD 2597.00 4287.00 261
2012 M & M ROYALTY LTD 13336.00 4487.00 366
2013 M & M ROYALTY LTD 5308.00 2305.00 365
2014 M & M ROYALTY LTD 3948.00 1792.00 365
2015 SOUND ENERGY CO INC 1733.00 1043.00 305
2016 SOUND ENERGY CO INC 2153.00 1200.00 365
2017 SOUND ENERGY CO INC 1361.00 1202.00 365
2018 SOUND ENERGY CO INC 1929.00 1170.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 M & M ROYALTY LTD Brine 0 0
2011 M & M ROYALTY LTD Brine 1745 261
2012 M & M ROYALTY LTD Brine 1323 366
2013 M & M ROYALTY LTD Brine 768 365
2014 M & M ROYALTY LTD Brine 814 365
2015 SOUND ENERGY CO INC Brine 755 305
2016 SOUND ENERGY CO INC Brine 572 365
2017 SOUND ENERGY CO INC Brine 538 365
2018 SOUND ENERGY CO INC Brine 399 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1247162963 2010-12-6 0:00: UD No Violations
-129316398 2010-12-28 0:00 UD No Violations
-1599041129 2019-5-31 0:00: UP No Violations 0.70
-173244135 2010-12-27 0:00 UD No Violations
-1879468117 2011-1-20 0:00: UD No Violations
-2117039447 2013-9-25 0:00: UL No Violations
-450080600 2011-11-22 0:00 PW No Violations
-654254921 2010-12-21 0:00 UD No Violations
-817359435 2011-11-7 0:00: PW No Violations
0129316398 2010-12-28 Urban Drill / Deepen / Reopen No Violations Turbo Excavating and Chem Tech were onsite to start solidifying and closing the drilling pits. Advent Drilling moved off on 12/21. Work should be completed by the first of the year.
0173244135 2010-12-27 Urban Drill / Deepen / Reopen No Violations Turbo Excavating is on site to begin pit solidification and closure. The first three loads of lime dust are scheduled to arrive on 12/28. No violations at this time.
0256664013 2011-11-01 Production Wells No Violations I received a anonymous (330-524-1572) call from a house on Palm Road about noise coming from the gas pumping unit. She stated that it has increased in noise from yesterday. She also stated that she lives 300 to 400 feet away from the pumping unit. I inspected the gas pumping unit and found the noise to be low. I called Mike Weinsz (330-324-1957) and met with Mike at the location. The fence around the pumping unit is getting installed. Mike will install a privacy fence around the west and north sides with a tarp inside to muffle the sound. A new car muffler will be installed to reduce the exhaust noise. The car muffler will be installed after Mikes crew measure for the right muffler. This complaint continues.
0450080600 2011-11-22 Production Wells No Violations I inspected the well pumping unit. It had the car mufflers installed and the pumping unit was running. The unit was as quite as a electric pumping unit. I called Tracy Dardenner (330-524-1572) of 2202 Palm Road to let her know that the mufflers had been installed but that I had not performed a decibel test yet. She stated that the noise was gone during the day but she could still hear some noise at night. She said she thought she could try and live with it. I called Gene Chini and gave him the update on this complaint. This complaint is resolved.
0654254921 2010-12-21 Urban Drill / Deepen / Reopen No Violations Advent Drilling is moving off location. The drilling pits are fenced, lined and in good condition. Turbo Excavating is scheduled to start pit solidification 12/28. No violations at this time.
0817359435 2011-11-07 Production Wells No Violations I received a call from Mrs. Tracy Dardenner, 2202 Palm Road (330-524-1572) about the noise at the pumping unit. The noise has been keeping her up all night. This complaint is a continuation of the anonymous complaint about the noise at the pumping unit (11-1-11). When I performed the inspection the pumping unit was not pumping but the fence was up with a tarp over the west and the northwest sides of the fence. Two car mufflers had been installed but were down on the ground. I called Mike Wiensz (330-324-19570) to find out why this well was not pumping. Mike stated that they installed the mufflers that morning but the down hole pump locked up when they turned the pump on. A workover rig will be on location by 11/11/11. The new mufflers have not run at all. I called Mrs. Dardenner back to let her know what was going on. Mike would call me when the well is back into production. I called Gene Chini to give him an update on this complaint. This complaint continues.
1247162963 2010-12-06 Urban Drill / Deepen / Reopen No Violations Advent is drilling ahead on air/soap in the top of the Salina section. The pits are fenced, lined and in good condition.
1253715289 2010-12-14 Urban Drill / Deepen / Reopen No Violations Advent Drilling is down for repairs to the mud pump. They switched over to fluid near the base of the Utica shale. No violations at this time.
1293553244 2010-12-16 Urban Drill / Deepen / Reopen No Violations Advent is drilling ahead on fluid. The pits are lined, fenced and in good condition. No violations at this time.
1296588694 2011-01-27 Urban Drill / Deepen / Reopen No Violations The well has been acidized with a good show of oil during flowback. On this date, Turbo Excavating and Chem Tech were on site to solidify and close the last drilling pit. M&M requested and were granted permission to relocate the tank battery 150 feet to the east and to increase both the individual size (210 bbl) and number (6) of stock tanks in the tank battery.
1297353709 2011-02-03 Urban Drill / Deepen / Reopen No Violations The well is still connected to a 500 bbl frac tank for flowback and testing purposes. The tank battery equipment is starting to be delivered.
1318340654 2011-09-27 Preliminary Restoration No Violations Preliminary Restoration is approved.
1437403433 2015-07-01 UrbanProduction Wells No Violations Follow up to complaint #5063 received on 7/30/15 concerning the noise from the pumping unit and the unit running all night. The southeast corner of the landowners home is 800 northwest of the pumping unit. The pumping unit is a Dansco 320D equipped with a natural gas powered motor. The motor is equipped with two (2) car muffler exhausts on the north side of the unit and away from the residence. Apparently, the unit would run only in the day and shut off at night and something has changed so that the unit is running all night and off during the day. I called the pumper, Bob Allen, and he told me that the controller (timer) was being repaired and he had to manually turn the unit on for continuous pumping several days of the week. I asked him to run the unit only during daylight hours to resolve the noise issues and he said that would not be a problem. I called the landowner and let her know of my findings and she seemed satisfied that the issue was going to be resolved. I gave her my cell number and asked her to call me directly if the issue continues. This complaint is resolved.
1441375895 2015-08-13 UrbanProduction Wells No Violations I was on location to check the status of this Rose Run well after ownership was transferred to Sound Energy on 5/12/15. The proper ID signs have been posted at the wellhead and the tank battery indicating Sound Energy as the new owner of the well. The emergency contact numbers have been updated. No violations.
1665666304 2011-04-27 Urban Drill / Deepen / Reopen No Violations The well is waiting for turn on and salesline completion. Preliminary restoration is due now and the site needs both grading and seed work. I will talk to M&M about completing the job.
1879468117 2011-01-20 Urban Drill / Deepen / Reopen No Violations On site to witness treating the Rose Run with 1500 gallons of hydrochloric acid. The service rig is Steve Hagen and the treating company is Universal Well Service. Flowback indicated a show of oil and gas. The decision to frac the well will be made at a later date.
2117039447 2013-09-25 UrbanPreliminary Restoration No Violations I was on location to inspect final restoration status of the Wohlwend 1-K which was a lost hole that was plugged and abandoned prior to this well being drilled. A check of records indicates that PR was passed by Bob Worstall on 9/27/2011. My inspection found the pumping unit fenced and locked. The tank battery was was diked, fenced, and the gate was locked. The battery contained 4-210 barrel stock tanks and a 100 barrel tank. There was a domestic hook up with 8psi on the gauge. The tanks were equipped with charcoal filters and lightning arrestors. The well was being produced through a fire heated, horizontal separator that was fenced and locked. All equipment meets the required set backs. The ID sign is posted on location. The site has been graded and seeded and vegitation is well established. Preliminary Restoration is approved. No violations.
256664013 2011-11-1 0:00: PW No Violations

For data sources see[9]

References