34-133-24419

Well Details

Well ID: 34-133-24419
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Atwater Township
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: VILLA BEACH UNIT
License Status: Producing
License Date: 2011-08-11
Spud Date: 2011-09-12
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2011-09-17
Well Total Depth: 4938.00 ft
Configuration: Vertical
Latitude: 41.020000
Longitude: -81.120000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-08-11 Proposed Formations:CLINTON, Issued Date:8/11/2011, Expired Date:8/10/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2011-09-02 CORRECTION TO WELL NUMBER
Reached Total Depth 2011-09-17
Completion Report Received 2011-11-07
Construction Permit Expires 2013-08-10
Change of Owner 2016-10-07 Operator changed from 2050, ORION PETRO CORP to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-12-15 4770 4853 36
4770 4853 36
4770 4853 36

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-10-25 H2O 15 72500 Gal 45000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 ORION PETRO CORP 0.00 0.00 23
2012 ORION PETRO CORP 1613.00 347.00 366
2013 ORION PETRO CORP 1180.00 359.00 365
2014 ORION PETRO CORP 863.00 123.00 365
2015 ORION PETRO CORP 743.00 249.00 365
2016 ORION PETRO CORP 500.00 119.00 273
2017 PIN OAK ENERGY PARTNERS LLC 1082.00 322.00 365
2018 PIN OAK ENERGY PARTNERS LLC 772.00 120.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 ORION PETRO CORP Brine 1270 23
2012 ORION PETRO CORP Brine 624 366
2013 ORION PETRO CORP Brine 219 365
2014 ORION PETRO CORP Brine 134 365
2015 ORION PETRO CORP Brine 96 365
2016 PIN OAK ENERGY PARTNERS LLC Brine 0 365
2017 PIN OAK ENERGY PARTNERS LLC Brine 118 365
2018 PIN OAK ENERGY PARTNERS LLC Brine 49 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1000262820 2011-9-17 0:00: DD No Violations
-1315040769 2017-11-21 0:00 PW No Violations 0.60
-134548978 2011-11-9 0:00: PL No Violations
-2124167844 2011-9-13 0:00: DD No Violations
-346531823 2011-9-12 0:00: DD No Violations
0023305217 2011-09-12 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 11.75 conductor by Petroset on Poulson rig #10. There were no violations at this time.
0134548978 2011-11-09 Preliminary Restoration No Violations The top soil on the drilling location has been rough graded. There were no violations at this time.
0346531823 2011-09-12 Drill / Deepen / Reopen No Violations I performed a status check on Roy Poulsons rig #10. The rig crew were still rigging the equipment up. The drilling pit was in place. There were no violations at this time.
0495642508 2011-09-13 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 8 5/8 casing by Petroset on Poulson rig #10. There were no violations at this time.
0862758419 2011-09-07 Drill / Deepen / Reopen No Violations I received a call from Mr. Robert Besau(330-257-2302)of Rte 224 in Atwater. He wanted to know about the drilling of the well and what the company is going to do for keeping the water out of the location. He also was concerned about the smell,his water well and oil getting into the ditch. Mr. Besau stated that they were making the location now. He is concerned about the noise of the pumping unit from his house. His house is 156 from the wellhead with a small woods as a barrier. I told him the electric motor would not make much of a noise. He wanted a guarantee that there would not be any noise coming from the pumping unit. I could not do that. I stated that I would check the drilling location out and talk to Orion about his concerns. I talked face to face with the Orion field superintendent Warren Shoenselt cell 330-464-9634 about this matter. He stated that Mr. Besau had talked with him about all these issues. Warren is going to treat this well as a HB-278 well. Warren will check his water well before the drilling starts. A charchol filter will be installed at the tank battery along with a privacy fence and trees will be planted. The wellhead will have a dike around it for the protection from the ditch. The tank battery will have a higher dike around it for the same reason. This complaint is resolved.
1000262820 2011-09-17 Drill / Deepen / Reopen No Violations I witnessed the cementing of 4.5 casing by Petroset on Poulson rig #10. There were no violations at this time.
1315040769 2017-11-21 Production Wells No Violations Status check inspection of this Clinton Sandstone well. My inspection found the wellhead equipped with 2.375 rods and tubing and operating with the aid of an electric powered pumping unit. Gauges indicate 100psi on the tubing and 50psi on the 4.5 production casing. The well produces to a diked tank battery on location and contains two (2) 100 barrel tanks, a 35 barrel poly tank, a vertical separator, and the associated meter run. A gauge at the separator indicates 60psi and there is a domestic tap and meter on the separator sales line and the valve is open. Identification is posted at the tank battery. No violations.
2011910702 2011-09-12 Drill / Deepen / Reopen No Violations I performed a rig inspection on Poulsons rig #10. The rig crew were running into the hole with 11.75 conductor. This inspection satisfies 1501:9-9-03. There were no violations at this time.
2124167844 2011-09-13 Drill / Deepen / Reopen No Violations I performed an inspection on Poulson rig #10. The rig were drilling an 11 hole on fluid and the depth was 299. This inspection satisfies 1501:9-9-03. There were no violations at this time.
23305217 2011-9-12 0:00: DD No Violations
495642508 2011-9-13 0:00: DD No Violations
862758419 2011-9-7 0:00:0 DD No Violations

For data sources see[9]

References