X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-133-24420

Well Details

Well ID: 34-133-24420
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Suffield Township
Operator Name: CHESAPEAKE EXPLORATION LLC
Well Pad ID: US-OH-000600
Farm/Lease Name: HOSEY POR
License Status: Plugged Back
License Date: 2011-08-22
Spud Date: 2011-08-26
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2011-10-08
Well Total Depth: 6455.00 ft
Configuration: Vertical
Latitude: 40.990000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-08-22 Proposed Formations:TRENTON-BLACK RIVER, Issued Date:8/22/2011, Expired Date:8/21/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Plugged Back 2011-10-08
Reached Total Depth 2011-10-08
Completion Report Received 2011-12-21
Construction Permit Expires 2012-08-21
End of Confidential Data 2012-10-08
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-09-16 10079 10500 80
2012-09-16 13707 13876 20
2012-09-16 13483 13652 20
2012-09-16 7679 8100 80
2012-09-16 13931 14100 20
2012-09-16 13259 13428 20
2012-09-16 11999 12141 80
2012-09-16 11519 11940 80
2012-09-16 12479 12900 80
2012-09-16 13036 13204 20
2012-09-16 9599 10022 80
13931 14100 20
13707 13876 20
13483 13652 20
13259 13428 20
13036 13204 20
12479 12900 80
11999 12141 80
11519 11940 80
11039 11460 80
10559 10980 80
10079 10500 80
9599 10022 80
9119 9540 80
8639 9060 80
8159 8580 80
7679 8100 80
7199 7620 80
6719 7140 80
6719 7140 80
2012-09-16 11039 11460 80
2012-09-16 10559 10980 80
2012-09-16 9119 9540 80
2012-09-16 7199 7620 80
2012-09-16 6719 7140 80
2012-09-16 8639 9060 80
2012-09-16 8159 8580 80

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/15/2011 11/15/2011 6200.00 6,415,458.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WBK-132L Weatherford Breaker No Hazardous Components 0.00
EC6110A, EC6629A Nalco Anti-Bacterial Agent, Scale Inhibitor Water 7732-18-5
Proprietary Quaternary Ammonium Salt
Proprietary Acrylate Polymer
Methanol 67-56-1
CS-500 SI FTS International Scale Inhibitor Ethylene glycol 107-21-1 10.00 0.00010000
10.1 - 15 HCL FTS International Acid Water 7732-18-5 85.00 0.15
Hydrochloric acid 7647-01-0 15.00 0.02
WGA-15L Weatherford Gelling Agent Distillates, petroleum, hydrotreated light 64742-47-8 70.00 0.11
Additional Ingredients Not Listed on MSDS
WCS-631LC Weatherford Clay Stabilizer No Hazardous Components 0.00
FF850 Foaming Agent FTS International Foaming Agent Ethylene glycol 107-21-1 5.00 0.00083000
Polyethylene glycol monobutyl ether 9004-77-7 20.00 0.00332000
Northern White Sand Weatherford Proppant - Natural Quartz 14808-60-7 100.00 11.57
Inhibitor - WAI-251LC Weatherford Corrosion Inhibitor N,N-Dimethylformamide 68-12-2 40.00 0.00044000
2-Butoxyethanol 111-76-2 7.00 0.00008000
Tar bases, quinoline derivatives,

benzyl chloride-quaternized

72480-70-7 13.00 0.00014000
Cinnamaldehyde (3-phenyl-2-propenal) 104-55-2 10.00 0.00011000
Triethyl phosphate 78-40-0 7.00 0.00008000
Isopropanol 67-63-0 7.00 0.00008000
Ethylene glycol 107-21-1 60.00 0.00066000
WBK-134 Weatherford Breaker Quartz 14808-60-7 10.00 0.00058000
Peroxydisulfuric acid, diammonium salt 7727-54-0 80.00 0.00460000
Shale Surf 1000 FTS International Surfactant (4R)-1-methyl-4-(prop-1-en-2-yl)cyclohexene 5989-27-5 10.00 0.00047000
Proprietary Polyethoxylated Alcohol 20.00 0.00094000
Methanol 67-56-1 10.00 0.00047000
2-Butoxyethanol 111-76-2 10.00 0.00047000
Isopropanol 67-63-0 10.00 0.00047000
NE-100 (NON-EMULSIFIER) FTS International Non-Emulsifier Isopropanol 67-63-0 10.00 0.00002000
Alkylaryl sulphonic acid 27176-87-0 5.00 0.00001000
2-Butoxyethanol 111-76-2 10.00 0.00002000
WXL-105L Weatherford Crosslinker Boric acid 10043-35-3 30.00 0.01
Ethanolamine 141-43-5 7.00 0.00248000
Ethylene glycol 107-21-1 60.00 0.02
LT Encapsulated AP Breaker (LTB01) FTS International Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00562000
Proprietary Cured Acrylic Resin 25.00 0.00141000
Quartz 14808-60-7 25.00 0.00141000
CI-150, CS-500 SI, FE-100L, FF-850,

FRW-200, HVG-4, KCLS-4, LTB-01, NE 100, SHALESURF 1000

FTS International Breaker, Clay Stabilizer, Corrosion Inhibitor, Foaming Agent, Friction Reducer, Gelling Agent, Iron Control Agent, Non-Emulsifier, Scale Inhibitor, Surfactant Water 7732-18-5
Proprietary Corrosion Inhibitor Additive (CI-150)
Proprietary Breaker Additive (LTB-1)
Non-MSDS Components Not Provided by Supplier
Proprietary Friction Reducer Additive

(FRW-200 and FRW-200W)

Proprietary Clay Stabilizer Additive (KCLS-4)
KCLS4 FTS International Clay Stabilizer No Hazardous Components 0.00
CI-150 (Corrosion Inhibitor) FTS International Corrosion Inhibitor N,N-Dimethylformamide 68-12-2 10.00 0.00005000
Proprietary Organic Amine Resin Salt 30.00 0.00015000
Proprietary Aromatic Aldehyde 10.00 0.00005000
Isopropanol 67-63-0 60.00 0.00030000
Proprietary Quaternary Ammonium Compound 10.00 0.00005000
EC6110A Nalco Antibacterial Agent Glutaraldehyde 111-30-8 60.00 0.01
Quaternary Ammonium Compounds 10.00 0.00214000
Ethanol 64-17-5 5.00 0.00107000
WBK-133, Breaker Weatherford Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00214000
WFR-61LA Weatherford Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 40.00 0.02
Ethoxylated C12-16 alcohols 68551-12-2 7.00 0.00376000
Sodium chloride 7647-14-5 10.00 0.00537000
Ammonium chloride 12125-02-9 7.00 0.00376000
pH Adjusting Agents - WPB-584L Weatherford pH Adjusting Agent Potassium hydroxide 1310-58-3 40.00 0.01
Carbonic acid, dipotassium salt 584-08-7 60.00 0.01
FE 100L (Iron Chelator) FTS International Iron Control Agent Citric acid 77-92-9 55.00 0.00053000
Carbon Dioxide FTS International Energizing Agent Carbon dioxide 124-38-9 100.00 1.34
EC6629A Nalco Scale Inhibitor No Hazardous Components 0.00
FRW-200 FTS International Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 26.00 0.00089000
HVG-4 FTS International Gelling Agent Guar gum, carboxymethyl 2-hydroxypropyl ether, sodium salt 68130-15-4 55.00 0.00762000
Distillates, petroleum, hydrotreated light 64742-47-8 55.00 0.00762000
Clay 5.00 0.00069000
WAI-251LC, WBK-132L, WBK-134, WCS-631LC,

WFR-61LA, WGA-15L, WIC-641L, WPB-584L, WXL-105L

Weatherford Breaker, Clay Stabilizer, Corrosion Inhibitor, Cross Linker, Friction Reducer, Gelling Agent, Iron Control Agent, pH Adjusting Agent Proprietary Breaker Additive (WBK-134)
Proprietary Alcohol
Carbonic acid, dipotassium salt 584-08-7
Non-MSDS Components Not Provided by Supplier
Proprietary Non-Hazardous Salt
Guar gum 9000-30-0
Proprietary Ethoxylated Nonylphenol
Sorbitan, (9Z)-9-octadecenoate (2:3) 8007-43-0
Proprietary Friction Reducer Additive (WFR-61LA)
Ethoxylated C12-16 alcohols 68551-12-2
Iron Control - WIC-641L Weatherford Iron Control Agent Citric acid 77-92-9 70.00 0.00341000
Fresh Water Carrier/Base Fluid 83.49
100 Mesh Sand Weatherford Proppant - Natural Quartz 14808-60-7 100.00 2.53
ACID, HYDROCHLORIC, 15 PCT Weatherford Acid Water 7732-18-5 85.00 0.36
Hydrochloric acid 7647-01-0 15.00 0.06

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 CHESAPEAKE APPALACHIA LLC Brine 1796 20
2012 CHESAPEAKE EXPLORATION LLC Brine 7207 0
2013 CHESAPEAKE EXPLORATION LLC Brine 0 0
2014 CHESAPEAKE EXPLORATION LLC Brine 0 0
2015 CHESAPEAKE EXPLORATION LLC Brine 0 0
2016 CHESAPEAKE EXPLORATION LLC Brine 0 0
2017 CHESAPEAKE EXPLORATION LLC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1015793989 2011-11-9 0:00: UL No Violations
-1084069126 2017-5-8 0:00:0 PB No Violations 3.90
-146096985 2011-9-17 0:00: DD No Violations
-1461268082 2017-5-9 0:00:0 PB No Violations 5.00
-1703284766 2011-11-9 0:00: UL No Violations
-1829272889 2017-7-21 0:00: FR No Violations 0.60
-209223859 2017-2-17 0:00: UP No Violations 0.50
-555235434 2017-5-12 0:00: PB No Violations 9.00
-775400352 2017-6-5 0:00:0 PB No Violations 1.00
-850301554 2017-5-17 0:00: PB No Violations 8.00
-939976266 2011-10-14 0:00 DD No Violations
0146096985 2011-09-17 Drill / Deepen / Reopen No Violations I performed a rig inspection on Paterson rig #329. The rig crew were helping run into the hole with 13 3/8 casing. This inspection satisfies 1501:9-9-03. There were no violations at this time.
0207200480 2011-11-09 Completion Testing No Violations The workover rig moved on-site and preparing for the frac crew which are due on location on 11/11/11. There were no violations at this time.
0209223859 2017-02-17 UrbanProduction Wells No Violations I was on location to inspect the status of this horizontal, Utica Shale well and well pad. The current status of this well is listed as temporary inactive (1st year) and is incorrect as the inactive status expired on 11/21/2014. A plugging permit was issued on 5/25/2015 and expires on 5/25/2017. The only commercial production reported for this well was from flow-back operations during the 4th quarter of 2011. My inspection today found the lease road and well pad in stable condition. The well pad is fenced and secured. Vegetation and small brush are beginning to take root on the pad, but does not present a serious issue at this time. The wellhead is secured with tubular steel fencing and two (2) steel grates cover the cellar. The main and wing gate valves are closed, chained & locked, and the well is shut-in. I will speak with Chesapeake about their plans to plug the well as the permit will expire in just over three (3) months. No violations.
0210543536 2013-11-06 UrbanProduction Wells No Violations I inspected this well at the request of Columbus in regards to an application for temporary inactive status (1st year) for this horizontal well. My inspection found that identification is posted at the lease road entrance, at the pad gate, and at the wellhead. Access road gate is currently open and being used by the farmer. Entire well pad is secured with chain link fencing and topped with three strands of barbed wire. The lease road and pad are in good condition and constructed of limestone. Access gates to the pad are locked. Completion operations were conducted on the well (perforating/fracing) in November of 2011, and during flow back operations, produced 583 barrels of oil, 0 mcf of natural gas and 1796 barrels of brine. Continued testing in 2012 did not yield any commercial quantities of gas or oil and 7207 barrels of brine. The wellhead is shut in, surrounded by a gate, and contained within a liquid tight cellar that is covered by metal panels. The gate valves on the wellhead are chained and locked. There is no production equipment or tank battery on the location. Security cameras are located at the entrance to the pad. No violations.
0225283247 2017-05-22 Plug / Plug Back No Violations I was on location to verify the integrity and level of the top plug in this recently abandoned Point Pleasant well. I tagged the top of the cement plug inside the 9.625 intermediate casing with a weight and measuring tape at a depth of two (2) feet below the top of the casing. I did not observe any leaks or gas bubbling through the fluid on top of the cement. I notified Jason Nicholas (Nicks Well Plugging) that the casing may be cut off, the ID plate attached, and that the tin horn can be removed. No violations.
0239605548 2011-10-31 UrbanPreliminary Restoration No Violations Most of the rig equipment is gone. The rest of the equipment will be gone today. There were no drilling pits. Good vegetation growth on the berms with a chain link fence around the drilling site. There were no violations at this time.
0555235434 2017-05-12 Plug / Plug Back No Violations I was on location with Chesapeake (CHK) company man Wallace Bossert, Nicks Well Plugging (NWP), Weatherford, and Energy Fishing Services (EFS) to continue with plugging operations on this horizontal, Utica-Point Pleasant well. EFS used the casing jacks to unseat the casing slips and recover the 5.5 productions casing. 492 of 20lb/ft., P-110 casing was recovered during he job and had to be chop-sawed at the casing collars while coming out of the hole. The inside of the 9.625 casing is coated with dehydrated drilling mud which will need to be removed and cleaned prior to setting plugs in the casing. EFS will bring out a 9.625 casing scraper on Monday morning (5/15/17). See plugging report for more details on this job. No violations.
0775400352 2017-06-05 Plug / Plug Back No Violations I was on location to inspect this pad following plugging and abandonment operations that concluded on 5/17/17. My inspection found that all equipment has been removed, the tin horn (cellar) has been removed, and the wellhead has been cut off below grade and buried. There is a large pile of stone on the east side of the pad. Final Restoration is due in August 2017 (3 months). No violations.
0777546231 2017-05-10 Plug / Plug Back No Violations I was on location today with Chesapeake (CHK) field representative Wallace Bossert and Nicks Well Plugging (NWP) to continue plugging operations on this Point Pleasant well. NWP ran 2.375 tubing to a depth of 4992 and tagged the top of the cast iron bridge plug. They then rigged up, established circulation, and then spotted a 200 plug on top of the bridge from 4992-4792. The cement was allowed to cure for 7 hours and NWP tagged the top of the bottom plug at 4770 with a sinker bar on the sand line. The tubing was spotted at 4510 and NWP mixed and pumped a 300 plug to isolate the Clinton Sandstone inside the 5.5 production casing. See plugging report for more details on this job. No violations.
0850301554 2017-05-17 Plug / Plug Back No Violations I was on location with Chesapeake (CHK) company man Wallace Bossert, Nicks Well Plugging (NWP), Weatherford, and Nine Energy Services (NES) to continue with plugging operations on this horizontal, Utica-Point Pleasant well. NES rigged up and ran inside the 9.625 casing and set a cast iron bridge plug at a depth of 450. Negative and positive pressure tests were performed on the plug and passed. The annular gas has been shut-off and plugging can continue. NWP spotted tubing at the top of the bridge plug and filled the 9.625 casing with cement from 450 to surface in two (2) stages. The hole was topped off and NWP began rigging down. See plugging report for more details on this job. No violations.
0939976266 2011-10-14 Drill / Deepen / Reopen No Violations Paterson is drilling ahead on the horizontal leg of this well. They anticipate completing the well by the first of next week. No violations at this time.
0952668256 2017-05-15 Plug / Plug Back No Violations I was on location with Chesapeake (CHK) company man Wallace Bossert, Nicks Well Plugging (NWP), Stallion, and Energy Fishing Services (EFS) to continue with plugging operations on this horizontal, Utica-Point Pleasant well. EFS rigged up the 9.625 casing scraper and NWP picked up the tool and tripped into the 9.625 casing. The tool made it to a depth of 75 and would no long move downhole. NWP brought in a swivel and they were able to wash 10 joints into the hole and circulate the mud out of the casing. The solids in the mud were filling up the cellar and caused operations to cease until 5/16/17. Wallace had a super-sucker clean out the cellar later in the afternoon. See plugging report for more details on this job. No violations.
1015793989 2011-11-09 UrbanPreliminary Restoration No Violations The chain link fence was installed and vegetation was growing on the berms around the drilling location. This well PASSES PRELIMINARY RESTORATION.
1016526079 2013-09-25 UrbanPreliminary Restoration No Violations I inspected this plugged back well as a status check of preliminary restoration (PR). A records check indicates that Carl Roberts approved PR on 11/9/2011. My inspection found that the entire pad was fenced and the gate was locked. Vegetation is well established around the perimeter of the location. There is no production equipment on location. The wellhead is gated and all of the gate valves are chained and locked. The cellar is full of water and the well is shut in. There is no sign of anything leaking. Preliminary Restoration is approved. No violations.
1084069126 2017-05-08 Plug / Plug Back No Violations I was on location today with Chesapeake (CHK) field personnel Wallace Bossert and Blake Riley, Nicks Well Plugging (NWP), and RBS Wireline Services to begin plugging this horizontal, Utica-Point Pleasant well. The well has been equipped with a 10,000psi blow-out-preventer (BOP) for plugging operations. RBS ran in the 2.375 tubing and set a kill plug at 6687 prior to pulling the tubing string. NWP stabbed into the tubing head, unseated the slips, and began recovering the tubing. No violations. See plugging report for more details on this job.
1266431414 2013-09-25 UrbanPreliminary Restoration No Violations I inspected this well as a status check of preliminary restoration (PR). A records check indicates that Carl Roberts approved PR on 11/9/2011. My inspection found that the entire pad was fenced and the gate was locked. Vegitation is well established around the perimeter of the location. There is no production equipment on location. The wellhead is gated and all of the gate valves are chained and locked. The cellar is full of water and the well is shut in. There is no sign of anything leaking. Preliminary Restoration is approved. No violations.
1314201001 2011-08-23 Drill / Deepen / Reopen No Violations I checked on this well to see if the Rat Hole rig has started drilling the cellar yet. The rig is still broke down. Not sure when it will be fixed. There were no violations at this time.
1314355757 2011-08-25 Drill / Deepen / Reopen No Violations I performed a status check on the location. The rat hole rig has started back on drilling the cellar. It is 2 feet deep. Needs to go around 10 to set the ten horn or cellar. There were no violations at this time.
1314725252 2011-08-26 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 30 conductor by OTEX cementing to 40. There were no violations at this time.
1315487656 2011-09-06 Drill / Deepen / Reopen No Violations I performed a status check on the Paterson rig 329 rigs move. The move has not started yet. I talked with the Chesapeake consultant, Craig Harris(432-634-7983) about the move. Only frac tanks, trailers are on the drilling location. There were no violations at this time.
1315852880 2011-09-12 Drill / Deepen / Reopen No Violations I performed a status check on Paterson rig #329. I talked with Craig Harris (Chespeake consultant) about the spud time. He thought the rig would spud sometime tonight. There were no violations at this time.
1315933184 2011-09-13 Drill / Deepen / Reopen No Violations The Paterson rig #329 has not spudded yet. Craig from Chesapeake was hoping to spud by noon today. There were no violations at this time.
1316310270 2011-09-17 Drill / Deepen / Reopen No Violations I witnessed the cementing of 13 3/8 casing by BJ Baker on Paterson rig #329. There were no violations at this time.
1319207680 2011-10-08 Plug / Plug Back No Violations Patterson Drilling Rig 329 finished drilling the 8-3/4 vertical pilot hole at 6455. On this date, Halliburton was on site to plug back to the Clinton/Queenston interval to begin the horizontal component of the well. The plug back footage totaled 2100 divided into three equal stages of 700. Halliburton mixed 310 sacks of Densecem cement for each stage. Densecem System is a Class H based blend with a weight of 17.2 ppg and a yield of 0.98 cf/sack. The plugs were spotted using open ended 5 drill pipe. Halliburton broke and maintained circulation throughout each stage.
1320083895 2011-10-31 UrbanPreliminary Restoration No Violations Most of the rig equipment is gone. The rest of the equipment will be gone today. There were no drilling pits. Good vegetation growth on the berms with a chain link fence around the drilling site. There were no violations at this time.
1320778854 2011-11-07 Completion Testing No Violations The Chesapeake consultants were waiting on the workover rig to show up. There were no violations at this time.
1456841628 2016-02-25 UrbanProduction Wells No Violations I conducted a status check inspection of this Utica Shale well pad. My inspection found the lease road gate present and open (this is access to the farmers field). The lease road and apron are in good repair. The pad is fenced and the entrance gate and all man doors on the perimeter of the pad were locked. The wellhead is surrounded by a liquid-tight cellar with a two-piece grate covering the cellar and tubular steel gates surrounding the wellhead. The wellhead consists of a 5.5 (flanged) production casing wellhead with double wing gate valves on each side. The christmas tree consists of two (2) main gate valves with double, tubing wing gate valves on each side, and a swab gate valve on top of the tree. The well is shut-in and gauges on the casing and tubing valves read 0psi. The gate valves are chained and locked. There is no surface equipment or tank battery on the well pad. Chesapeake has applied for, and been issued, a plugging permit for this well that will expire on 5/25/2017. Video surveillance monitoring has been removed from the location. Note: Temporary Inactive status for this well expired in November of 2014.
1461268082 2017-05-09 Plug / Plug Back No Violations I was on location today with Chesapeake (CHK) field representative Wallace Bossert, Nicks Well Plugging (NWP), and Nine Energy Services (NES) to begin plugging operations on this Point Pleasant, horizontal well. NWP pulled the remaining tubing from the well and NES rigged up and ran a junk basket and gauge ring to 5050 to verify drift diameter. The tools were pulled and NES ran in and set a cast iron bridge plug (CIBP) at a depth of 4992. The CIBP was tested at 5000psi for fifteen minutes with no leak-off and operations continued. NWP began tripping 2.375 tubing back into the 5.5 production casing and will begin setting cement plugs in the morning (5/10/17). See plugging report for more details on this job. No violations.
1496165983 2017-05-11 Plug / Plug Back No Violations I was on location with Chesapeake (CHK) company man Wallace Bossert and Nicks Well Plugging (NWP) to continue with plugging operations on this horizontal, Utica-Point Pleasant well. NWP spotted plugs inside the 5.5 production casing across the top of the Big Lime and at the 9.625 intermediate casing shoe. The tubing was pulled and the crew was waiting on the casing shooters. I left location for the Murvay 8H (24423). See plugging report for more details on this job. No violations.
1496775976 2017-05-11 Plug / Plug Back No Violations I was on location with Chesapeake (CHK) company men Wallace Bossert and Blake Riley, Nicks Well Plugging (NWP), and Nine Energy Services (NES) to continue with plugging operations on this horizontal, Utica-Point Pleasant well. NES ran into the hole and shot the 5.5 production casing off at a depth of 492. A casing spear and grapple was set in the 5.5 casing and NWP pulled 75,000lbs on the casing and could not unseat the casing slips. It was decided to bring out casing jacks in the morning and attempt to recover the pipe. See plugging report for more details on this job. No violations.
1693950177 2017-05-16 Plug / Plug Back No Violations I was on location with Chesapeake (CHK) company man Wallace Bossert, Nicks Well Plugging (NWP), Weatherford, and Energy Fishing Services (EFS) to continue with plugging operations on this horizontal, Utica-Point Pleasant well. EFS and NWP continued to circulate and scrape the inside of the 9.625 casing. The 5.5 casing stub was tagged at 492 and the hole was swept with S-410, P-32, and diesel fuel to remove the oil residue from the casing walls. The tool was pulled and Weatherford ran a cement bond log (CBL). The CBL indicated no recoverable 9.625 casing and the remaining plugs will be s inside this casing. The annulus between the 5.5 casing and 9.625 casing continued to release low pressure gas and it was decided to set a cast iron bridge plug inside the 9.625 casing tomorrow morning (5/17/17). See plugging report for more details on this job. No violations.
1703284766 2011-11-09 UrbanPreliminary Restoration No Violations The vegetation was growing on the berms around the drilling location. The chain link fence was around the drilling location. This well PASSES PRELIMINARY RESTORATION.
1829272889 2017-07-21 Final Restoration No Violations I was on location to conduct a Final Restoration inspection of this plugged and abandoned Utica/Point Pleasant well that was plugged on 5/17/2017. The landowner, Mr. Edward Hosey, has executed the Landowner Waiver (Form 5) and has waived removal of the chain link fencing, removal of the entire access road, and removal of the entire well pad. My inspection today found that all equipment has been removed. The wellhead and cellar were cut off and buried following plugging operations and the area has been rough graded. A flow line, sales line, and tank battery were never installed or constructed for this well. The well pad is limestone and the establishment of vegetative cover is not required. Final Restoration is approved.
207200480 2011-11-9 0:00: CT No Violations
210543536 2013-11-6 0:00: UP No Violations
225283247 2017-5-22 0:00: PB No Violations 1.00
239605548 2011-10-31 0:00 UL No Violations
777546231 2017-5-10 0:00: PB No Violations 7.30
952668256 2017-5-15 0:00: PB No Violations 9.10

For data sources see[7]