34-133-24426

Well Details

Well ID: 34-133-24426
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Rootstown Township
Operator Name: PEP DRILLING LLC
Well Pad ID:
Farm/Lease Name: LITSINGER
License Status: Producing
License Date: 2014-06-13
Spud Date: 2012-08-21
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2012-09-05
Well Total Depth:
Configuration: Vertical
Latitude: 41.090000
Longitude: -81.200000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-12-23 Proposed Formations:CLINTON, Issued Date:12/23/2011, Expired Date:12/22/2013 12:00:00 PM, Drilling unit acres:58, Proposed Well Type:OG, Proposed Well Class:POOL
Change of Owner 2012-04-09 Operator changed from 1, HOPEWELL OIL & GAS DEVELOPMENT to 1198, PIPES PURSIE E
APP 2012-06-15 Proposed Formations:CLINTON/ROSE RUN, Issued Date:6/15/2012, Expired Date:6/15/2014 12:00:00 PM, Drilling unit acres:58, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2012-09-05
Correction to Well 2013-12-20 CORRECTION TO X,Y COORDINATES, ELEVATION AND UNIT SIZE CHANGED TO 61.23 ACRES.
Completion Report Received 2014-01-14
APP 2014-06-13 Proposed Formations:CLINTON, Issued Date:6/13/2014, Expired Date:6/12/2016 12:00:00 PM, Drilling unit acres:58, Proposed Well Type:OG, Proposed Well Class:POOL
Plugged Back 2014-06-25
Construction Permit Expires 2015-06-13
Change of Owner 2016-03-04 Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC
Record Last Modified 2017-10-23

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-07-31 H2O 0 78000 Gal 10000 Universal Well Services Inc. Universal rigged up to the well head and tested the lines at 3100psi with no leaks. The pressure was released and the gate valve was opened. The annulus between the surface casing and production casing was open. Universal displaced the acid in 2 stages and broke the formation at 1271psi. They established rate at 15.8 barrels/minute (bpm) and began slickwater with 0.25 lbs of 20/40 sand per gallon. The formation treated at an average rate of 22.1 bpm and the job went as designed. There was
2014-06-30 H2O 0 74319 Gal 7500 Universal Well Services Inc. I was on location with Pursie Pipes, Mark Smith, Perry Pipes, and Universal Well Services to observe slick water frac operations being conducted on the Clinton Sandstone. Universal tested the lines, opened the gate valve, and I confirmed that the annulus between the 4.5" production casing and 8.625" surface casing was open. They broke the formation at 1084psi and displaced 1000 gallons of 15% HCL in 4 stages. They established rate, began sand at 0.25ppg, pumped for 10 minutes and had to flush

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 PIPES PURSIE E 0.00 0.00 91
2014 PIPES PURSIE E 858.00 102.00 365
2016 PEP DRILLING LLC 1335.00 111.00 365
2017 PEP DRILLING LLC 876.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 PIPES PURSIE E Brine 1810 91
2014 PIPES PURSIE E Brine 835 365
2016 PEP DRILLING LLC Brine 0 365
2017 PEP DRILLING LLC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1184668839 2013-9-5 0:00:0 CT No Violations
-1203173566 2013-7-29 0:00: AM No Violations
-1266164928 2012-8-22 0:00: UD No Violations
-1543970235 2013-7-2 0:00:0 WR No Violations
-1602363212 2019-7-22 0:00: UL No Violations 0.60
-1689177234 2012-8-24 0:00: UD No Violations
-1829643601 2013-8-2 0:00:0 CT No Violations
-507048636 2012-8-17 0:00: DD No Violations
-56124051 2014-6-30 0:00: CT No Violations 4.00
-69414604 2012-7-25 0:00: AM No Violations
-71174592 2014-6-20 0:00: PB No Violations 3.00
-819422953 2013-10-28 0:00 UP No Violations
-906671643 2012-8-21 0:00: UD No Violations
0056124051 2014-06-30 Completion Testing No Violations I was on location to witness the hydraulic fracturing of the Clinton Sandstone in this recently plugged-back well. Universal Well Services conducted the stimulation operations. Pursie Pipes, Perry Pipes, and Mark Smith were on location overseeing the frac job. The formation broke down at 1,084psi and the well was treated with 1,000 gallons of HCL, 74,319 gallons of water, and 7500 pounds of proppant. The job went as designed. See stimulation report for more details on this job. No violations.
0069414604 2012-07-25 Administrative Inspection No Violations Talked to Mark Smith (PEP Drilling) on 7/20/12 about building the lease road. I granted PEP permission to move the lease road approximately 150-200 east of the original proposed location. The move was approved by Rootstown Zoning and moved the entrance away from a guardrail. I was on location to GPS the new entrance and inspect the apron and road. The apron and road were in good condition and constructed of durable material. No violations. Note: The well status is listed as cancelled and I have a call into Steve Opritza (Division of Oil & Gas) to check the discrepancy as of 7/27/12.
0071174592 2014-06-20 Plug / Plug Back No Violations I was on location to continue with plug-back operations. Mark Smith, Appalachian Well Surveys, and Chipco were on location to conduct operations. Appalachian ran in the 4.5 casing with a 10 perforating string and perforated the casing at the top of the Trenton Limestone from 6,264-6,274. Chipco will run the tubing back in to a depth of 6,274 and a squeeze plug and isolation plug will be set on Monday (6/23/14).
0145223001 2012-08-16 Drill / Deepen / Reopen No Violations I was on location at the request of Mark Smith to discuss changing the rig and pit layout that was decided on during the pre-site review with Bob Worstall on 5/2/2012. After discussion, I granted the proposed change so that the rig would could be oriented north-south and the pits could be placed to the west of the rig due to the presence of a low drainage area and field tile immediately to the east and south. I granted this change on the condition that the excavated soil be placed as a large embankment to the west of the pits to protect the tree line from any gas flares or blow-outs.
0175522428 2012-10-05 Urban Drill / Deepen / Reopen No Violations During this status check inspection, Mark Smith (PEP) was on location with Chipcos service rig attempting to drill out the two stage cementing tool that was run in the well during the production casing cement job. I talked with Mark and he informed me that they were not told about the two stage tool and discovered it when they sat down on it with a perforating gun the previous week. They were attempting to drill out the plug and the mill-tooth bit broke apart so they were trying to get the metal out of the hole with a magnet. They are going to continue and try to drill out the tool for the remainder of the day. No violations.
0507048636 2012-08-17 Drill / Deepen / Reopen No Violations I was on location to inspect the pits Pyramid Pipeline was excavating on this site. The pits were free of rock or sharp objects and the excavated soil was being stockpiled to the west in front of the treeline as I requested. No violations.
0524762359 2013-06-27 Work Over Reconditioning No Violations I was on location to inspect the remedial work on this Rose Run well. Chipco was on location making repairs to their service rig. They will start running tubing in the hole tomorrow with a a mill bit to try and get through the obstruction at the two-stage cementing tool. No violations.
0545193954 2013-10-17 UrbanProduction Wells No Violations I was on location to follow up on complaint #4504 about a loud popping noise emanating from this location. The pumping unit was operating with a natural gas motor and was equipped with an exhaust that emitted a low frequency popping sound when operating. The exhaust was directed to the northwest and the house of the complainant was approximately 1200 to the west of the location. I went to the house and could hear the exhaust from the pumping unit. I called Mark Smith (PEP) to see if there was a way to reduce the noise and he said he would attach another muffler to the end of the other muffler to reduce the noise. I will check back in several days on the progress.
0708366163 2013-06-28 Work Over Reconditioning No Violations I was on location to inspect the remedial work on this Rose Run well. Chipco was on location and tripping into the hole with tubing collars, tubing, and a mill bit to try and drill out an obstruction encountered near the two stage cementing tool. They will likely begin milling on Monday. No violations.
0819422953 2013-10-28 UrbanProduction Wells No Violations I was on location to follow up on complaint #4504 concerning a noisy exhaust. My inspection found that the second muffler has been installed on the natural gas powered pumping unit. This should mitgate the noise reaching the home to the west. This issue has been addressed. No violations.
0884362996 2014-06-17 Plug / Plug Back No Violations I was on location to check the preparation status for plug back operations. Chipco was rigged-up over the hole pulling rods and tubing. They will run the tubing back into the hole and should be ready to begin plug-back operations on 6/19/14. No violations.
0906671643 2012-08-21 Urban Drill / Deepen / Reopen No Violations I arrived on location and delivered the proper permit to Allen Irwin and we reviewed the conditions in the permit. They finished digging and lining the working pit. No violations.
1184668839 2013-09-05 Completion Testing No Violations I was on location to check the status of this well following completion operations. A Lufkin pumping unit has been installed and is operating with propane being supplied by a temporary 250 gallon steel tank on a skid. The unit is currently pumping and producing to a newly constructed tank battery near the entrance of the lease road. The battery is diked and contains 2-210 barrel tanks and a vertical separator which is not yet plumbed into flow line or tanks. There are charcoal filters on the vent stacks of the tanks. Pressure gauges showed 580psi on the tubing and 445psi on the casing. 2-500 barrel frac tanks are on location and ready to be hauled out. This site still requires preliminary restoration. No violations.
1203173566 2013-07-29 Administrative Inspection No Violations I was on location with Mark Smith and Appalachian Well Surveys to observe the running of the down hole camera into the 4.5 casing. The camera was being run to verify casing integrity following drill out of an obstruction in the two-stage cementing tool. Integrity was previously established with a pressure test after the drill out on 7/8/13. The camera was run and reached the top of the tool collar. There was no apparent damaged to the inside of the casing, at the collars, or inside the tool. Stimulation operations will commence on 7/31/13. No violations.
1208027502 2013-07-09 Work Over Reconditioning No Violations I was on location to check the status of operations. Chipco is rigging down and moving off location. No violations.
1266164928 2012-08-22 Urban Drill / Deepen / Reopen No Violations I was on location at 6:00am to witness the cementing of the conductor pipe. PEP Drilling drilled a 14.75 hole to a total depth of 146 at the kelly bushing (KB +10) and ran 126 (KB) of 11.75 conductor into the hole. Universal Well Services rigged up, established circulation, and cemented the conductor pipe with 85 sacks of Type 1 cement. 1.5 barrels of cement returned to and held at the surface. See cement/casing ticket for more details.
1376058208 2013-06-25 Work Over Reconditioning No Violations I was on location to check the status of this Rose Run well. The Chipco service rig was on location but there was no activity at this time. The location was in good condition. No violations.
1376661826 2013-07-08 Work Over Reconditioning No Violations I was on location to witness a casing integrity pressure test on this Rose Run well following the drill out of an obstruction. Producer Service Corporation was on location with Mark Smith (PEP) and Chipco. A 5000psi rated gate valve was threaded onto the 4.5 casing and was rigged up to the pump truck and the hole was loaded. At the start of the test, the bottom of the gate valve began leaking. The valve was removed and it was determined that the threads on the valve were worn enough that it could not be used. A 4x2 swedge valve was used in place of the gate valve. The pump truck rigged up to the swedge and began the test. 2,737psi was placed on the casing and after 30 minutes the pressure was 2,644psi (a loss of 3.4%). Casing integrity has been verified in accordance with OAC:1501-9-08 (3) and well completion operations may continue. No violations.
1378473784 2013-07-31 Completion Testing No Violations I was on location with Pursie Pipes, Mark Smith, Chipco, and Universal Well Services to witness the hydraulic fracturing of this Rose Run well. Universal rigged up to the well head and tested the lines at 3100psi with no leaks. The pressure was released and the gate valve was opened. The annulus between the surface casing and production casing was open. The stimulation went as designed and there were no pressure deviations during the job. See stimulation report for details on this job. No violations.
1379439891 2013-09-16 Completion Testing No Violations I was on location to check the status of this recently completed well. The well is still being tested for commercial viability. The 2-500 barrel frac tanks have been removed from location. No violations.
1409344500 2012-08-20 Urban Drill / Deepen / Reopen No Violations I arrived on location and found that PEP Drilling was rigging up. I talked with Allen Irwin (toolpusher) and he said they planned to spud the well in the morning. I asked if he had reviewed the permit conditions and discovered that he had been given a copy of the old permit. I told him I would bring him a copy first thing in the morning. A copy of the permit was posted at the entrance off Tallmadge Road. As I was leaving location, a street sweeper was delivered to take care of the mud on Tallmadge Road. No violations.
1416403344 2014-06-23 Plug / Plug Back No Violations I was on location to witness plug-back operations. Chipco spotted 2.375 tubing at 6,274 at the base of the perforations. Petroset rigged up, loaded the hole, and spotted 13 barrels of cement slurry in the 4.5 casing. Chipco pulled 30 joints of tubing, packed in the wellhead, and Petroset rigged up to the tubing and squeezed 6 barrels of cement through the perforations at 1000psi. Chipco pulled the tubing up to 4,850 and Petroset spotted an isolation plug to 4,650. I spoke with Mark Smith (PEP) on 6/25/14 and he tagged the isolation plug at 4,650 and set a mechanical bridge plug at 4,567, 10 above the two-stage cementing tool. Completion operations for the Clinton Sandstone will commence on 6/30/14. See plug report for more details on this job. No violations.
145223001 2012-8-16 0:00: DD No Violations
1455364425 2013-10-01 Completion Testing No Violations I was on location to check the status of this well. The well was still being tested to determine the commercial viability of the Rose Run Sandstone. The well was plumbed into a separator and the liquids were being produced to 210 barrel tanks. Gas was being sold into a Dominion line through a new Roots Meter. I talked with Mark Smith (PEP) and he is trying to get a bigger dozer out here to reclaim the location before winter. No violations.
1543970235 2013-07-02 Work Over Reconditioning No Violations I was on location to check the status of workover operations on this well. Chipco was preparing to run into the hole with the new mill bit. No violations.
1689177234 2012-08-24 Urban Drill / Deepen / Reopen No Violations I was on location at 9:00am to witness the cementing of the surface casing. PEP Drilling drilled an 11 hole to a total depth of 758 at the kelly bushing (KB +10) and set 738 (KB) of 8.625 surface casing in the hole. Universal rigged up, established circulation, and cemented the surface casing with 195 sacks of tail and lead cement. 3 barrels of cement returned and the cement held at the surface. See casing/cement ticket for more details.
1722673313 2013-07-03 Work Over Reconditioning No Violations I was on location to check on the progress of drilling out an obstruction in this well. Chipco has successfully milled through the obstruction in the two stage tool and ran to the bottom of the hole with the tubing. The casing will be pressure tested on Monday 7/8/13 to verify casing integrity. No violations.
175522428 2012-10-5 0:00: UD No Violations
1808999224 2013-08-19 Completion Testing No Violations I was on location to check the status of this well following completion. The service rig was gone from location and the well was shut in. Two frac tanks remained on location. I met with the landowner and discussed getting the site put back together. I will talk to Mark Smith (PEP) about a time frame for restoration. No violations.
1829643601 2013-08-02 Completion Testing No Violations I was on location to check the status of this well following stimulation on 7/31/13. Chipcos service rig was rigged over the hole and swabbing the flowback. All fluids are being contained/swabbed to a steel tank through a 2 steel line. No violations.
1996152407 2012-08-24 Urban Drill / Deepen / Reopen No Violations I was on location at 10:00pm to witness the testing of the blow-out-preventor (BOP). PEP drilling closed the annular on the drill pipe and pressured up to 500 psi. The pressure was held for 15 minutes with no observable leak-off on the gauge or in the cellar. No violations.
2005629396 2013-07-01 Work Over Reconditioning No Violations I was on location to check the status of this Rose Run well. Mark Smith was on location with Baker Atlas and Chipco. Chipco had been milling on the obstruction most of the morning and tripped out of the hole. The mill bits teeth were worn away and the bit was badly damaged. An impression block was prepared with tar and Chipco ran it into the hole on a sand line. They tagged the obstruction and pulled it out of the hole. Half of the tar pulled off of the block and we were unable to determine the nature of the obstruction. The Baker representative was going to return tomorrow with a new mill bit. No violations.
2092975735 2014-07-30 UrbanPreliminary Restoration No Violations I was on location to check the preliminary restoration status of this well. This well was plugged back to the Clinton Sandstone and re-completed on 6/30/14. The well is equipped with a gas pumping unit and gauges at the wellhead indicate 440psi on the casing and 125psi on the tubing. The belt guard is off of the pumping unit. The tank battery needs to be fenced and is properly diked. The battery contains 2-210 barrel tanks and are equipped with the required charcoal filters. The battery also contains a vertical separator with 125psi on the gauge and a Dominion meter run. The required ID is posted at the tank battery. I spoke with Mark Smith (PEP) about the belt guard and fencing. He told me he would get the belt guard on immediately and that the fencing should be up next week. I will check back next week to see if the work has been done or the well will have to be shut-in until it is completed.
2143362626 2014-06-19 Plug / Plug Back No Violations I was on location to witness plug back operations conducted by Chipco and Petroset Cementing. Company man Mark Smith was overseeing operations. Chipco sat down at 7171 with 2.375 tubing and picked up a joint to 7139 to set the bottom plug. Petroset rigged up and broke circulation. They then mixed and pumped 6.3 barrels of cement slurry and began displacing the slurry to 6828 with salt water. The hole was circulating gas cut oil and water to the tub and I had Chipco shut down their rig motor as a safety precaution. The cement set up in the tubing 1.6 barrels (403) short of displacement. I calculated the top of the cement at just over 200 above the formation top and this satisfies OAC 1501:9-11-08(1) of the plugging requirements. The tubing string was pulled and the cement had filled 23 joints. Squeeze and plug-back operations will continue tomorrow. No violations.
524762359 2013-6-27 0:00: WR No Violations
545193954 2013-10-17 0:00 UP No Violations
708366163 2013-6-28 0:00: WR No Violations
884362996 2014-6-17 0:00: PB No Violations 1.00

For data sources see[8]

References