Well ID: 34-139-20105 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.71,"lon":-82.35,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Richland | |
Municipality: Monroe Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: COWELL H G | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1949-09-29 | |
Spud Drilling Contractor: | |
Final Drill Date: 1949-10-25 | |
Well Total Depth: 2426.00 ft | |
Configuration: Vertical | |
Latitude: 40.710000 | |
Longitude: -82.350000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1949-09-29 | GL=P-1020.2-G, STORAGE |
Completed | 1949-10-25 | GL=P-1020.2-G, STORAGE |
Reached Total Depth | 1949-10-25 | GL=P-1020.2-G, STORAGE |
Change of Owner | 2011-10-18 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
Record Last Modified | 2013-03-11 | GL=P-1020.2-G, STORAGE |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-09-24 | H2O | 0 | 12599 Gal | 24500 | Universal Well Services Inc. | This job used a crosslinked polymer fluid assisted by nitrogen. Guar was the polyermizing agent. Nitrogen comprised 20% of the total volume with total nitrogen used at 50,000 cubic feet. No issues were noted during the job. |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1561346604 | 2015-12-1 0:00: | SO | No Violations | 0.50 |
-196158945 | 2013-9-24 0:00: | SO | No Violations | 3.00 |
-364003471 | 2019-3-15 0:00: | SO | No Violations | |
-427731852 | 2018-11-9 0:00: | SO | No Violations | |
0196158945 | 2013-09-24 | Storage Well | No Violations | Columbia requested ODNR to witness fracture stimulation of the well following reconditioning. |
0276181644 | 2019-04-03 | Storage Well | No Violations | Identification is posted . Drip connected to wellhead. Wellsite is maintained. |
0364003471 | 2019-03-15 | Storage Well | No Violations | Identification is posted. Well is connected to a drip. Rural domestic meter tap at wellsite. Wellsite is maintained |
0414847016 | 2017-12-05 | Storage Well | No Violations | ID is posted and the location is maintained. The gate valve and annulus are shut in. There is a 5 barrel tank connected to the separator. The tank is empty. The well is equipped with a house gas tap at the pipeline tie in. |
0427731852 | 2018-11-09 | Storage Well | No Violations | ID is posted and the location is maintained. The annulus is shut in. The well is equipped with a separator, 5 barrel tank and house gas connection at the pipeline tie in. |
1042234918 | 2014-12-17 | Storage Well | No Violations | ID posted, location maintained. There is a 5 Bbl tank connected to the well. The well is shut in at the drip. |
1376938931 | 2013-08-19 | Storage Well | No Violations | Columbia Gas is reworking the storage well. The operator requested ODNR witness the cementing of 3.5 inch liner in the well. Incorrect ID is posted on the well. |
1382363843 | 2013-10-17 | Storage Well | No Violations | The site has been finish graded, seeded and mulched. The well recently underwent a workover. |
1536287777 | 2020-6-26 0:00: | SO | No Violations | |
1561346604 | 2015-12-01 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve. The annulus is shut in. There is a 5 barrel fluid tank at the well. The tank is empty. |
1743459179 | 2013-08-21 | Work Over Reconditioning | No Violations | Columbia Gas requested ODNR witness the surface casing cement job. See the casing report for details. |
2088217167 | 2016-12-07 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in. There is a 5 barrel tank connected to the separator. There is a house gas meter at the well. |
276181644 | 2019-4-3 0:00:0 | SO | No Violations | |
414847016 | 2017-12-5 0:00: | SO | No Violations |
For data sources see[4]