X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-139-20539

Well Details

Well ID: 34-139-20539
Loading map...
Country: United States
State: Ohio
County: Richland
Municipality: Springfield Township
Operator Name: HOUGHTON INVESTMENTS LLC
Well Pad ID:
Farm/Lease Name: BEER CHESTER ETAL
License Status: Producing
License Date: 1973-03-19
Spud Date: 1973-03-22
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1973-03-28
Well Total Depth: 4166.00 ft
Configuration: Vertical
Latitude: 40.780000
Longitude: -82.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1802-01-01
Original Spud 1973-03-22
Completed 1973-03-28
Reached Total Depth 1973-03-28
Completion Report Received 1973-05-17
CO 1987-09-21 2838 ROSCOE GAS & OIL CO
CO 1995-07-18 213 LOMAK OPERATING CO GeoDate
Change of Owner 1998-09-17 Operator changed from 213, LOMAK OPERATING CO to 6227, HOUGHTON INVESTMENTS, L.L.C.
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 2000 Gal 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 CYCLOPS CORP 7422.00 11622.00 346
1986 CYCLOPS CORP 10907.00 10784.00 337
1987 ROSCOE GAS & OIL CO 0.00 0.00 0
1988 ROSCOE GAS & OIL CO 10243.00 11943.00 365
1995 TRANSFUEL RESOURCES CO 682.00 0.00 270
1996 RANGE OPERATING COMPANY 0.00 120.00 31
1998 HOUGHTON INVESTMENTS LLC 0.00 320.00 102
1999 HOUGHTON INVESTMENTS LLC 0.00 1625.00 0
2000 HOUGHTON INVESTMENTS LLC 0.00 2857.00 0
2001 HOUGHTON INVESTMENTS LLC 0.00 2500.00 365
2002 HOUGHTON INVESTMENTS LLC 0.00 1878.00 365
2003 HOUGHTON INVESTMENTS LLC 0.00 2155.00 365
2004 HOUGHTON INVESTMENTS LLC 0.00 3026.00 365
2005 HOUGHTON INVESTMENTS LLC 0.00 2772.00 365
2006 HOUGHTON INVESTMENTS LLC 0.00 3044.00 365
2007 HOUGHTON INVESTMENTS LLC 0.00 2535.00 365
2008 HOUGHTON INVESTMENTS LLC 0.00 1158.00 365
2009 HOUGHTON INVESTMENTS LLC 0.00 1818.00 365
2010 HOUGHTON INVESTMENTS LLC 0.00 3041.00 365
2011 HOUGHTON INVESTMENTS LLC 0.00 2397.00 365
2012 HOUGHTON INVESTMENTS LLC 0.00 2432.00 366
2013 HOUGHTON INVESTMENTS LLC 0.00 2865.00 365
2014 HOUGHTON INVESTMENTS LLC 0.00 2983.00 365
2015 HOUGHTON INVESTMENTS LLC 0.00 3093.00 365
2016 HOUGHTON INVESTMENTS LLC 0.00 2606.00 365
2017 HOUGHTON INVESTMENTS LLC 0.00 2189.00 365
2018 HOUGHTON INVESTMENTS LLC 0.00 1668.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 CYCLOPS CORP Brine 0 346
1986 CYCLOPS CORP Brine 487 337
1987 ROSCOE GAS & OIL CO Brine 140 0
1988 ROSCOE GAS & OIL CO Brine 0 365
1995 TRANSFUEL RESOURCES CO Brine 0 270
1996 RANGE OPERATING COMPANY Brine 0 31
1998 HOUGHTON INVESTMENTS LLC Brine 621 102
1999 HOUGHTON INVESTMENTS LLC Brine 2660
2000 HOUGHTON INVESTMENTS LLC Brine 1938
2001 HOUGHTON INVESTMENTS LLC Brine 3740 365
2002 HOUGHTON INVESTMENTS LLC Brine 4020 365
2003 HOUGHTON INVESTMENTS LLC Brine 5190 365
2004 HOUGHTON INVESTMENTS LLC Brine 3840 365
2005 HOUGHTON INVESTMENTS LLC Brine 5400 365
2006 HOUGHTON INVESTMENTS LLC Brine 0 365
2007 HOUGHTON INVESTMENTS LLC Brine 0 365
2008 HOUGHTON INVESTMENTS LLC Brine 1000 365
2009 HOUGHTON INVESTMENTS LLC Brine 4427 365
2010 HOUGHTON INVESTMENTS LLC Brine 6520 365
2011 HOUGHTON INVESTMENTS LLC Brine 6789 365
2012 HOUGHTON INVESTMENTS LLC Brine 7255 366
2013 HOUGHTON INVESTMENTS LLC Brine 9195 365
2014 HOUGHTON INVESTMENTS LLC Brine 8170 365
2015 HOUGHTON INVESTMENTS LLC Brine 8460 365
2016 HOUGHTON INVESTMENTS LLC Brine 8260 365
2017 HOUGHTON INVESTMENTS LLC Brine 7490 365
2018 HOUGHTON INVESTMENTS LLC Brine 6830 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1011610360 2009-12-14 0:00 PW No Violations
-1152978733 2003-5-29 0:00: PW No Violations
-13219123 2017-4-25 0:00: PW No Violations 1.50
-134017356 2016-8-1 0:00:0 PW No Violations 2.00
-1405257914 2016-8-9 0:00:0 PW No Violations 1.00
-1619222885 2016-12-1 0:00: PW No Violations 2.00
-344200666 2007-6-21 0:00: PW No Violations
-45217313 2017-1-26 0:00: PW No Violations 0.50
-461171197 2016-7-28 0:00: PW No Violations 2.00
-625827014 2010-11-8 0:00: PW No Violations
0013219123 2017-04-25 Production Wells No Violations The dyke around the tank battery contains water which tested 5.6 on the high range Quantab chloride test strip. This corresponds to 1303 parts per million chlorides. Kevin Mullins was contacted to clean up water from the containment. He stated that they isolated each of the 3 production tanks and measured fluid levels in the tanks and that the tanks are not leaking. He also stated that the salt in the containment is from maintenance last year when they replaced a tank and spilled some brine within the containment dyke. The containment is lined. Salt levels are dropping slowly as indicated on field test results.
0045217313 2017-01-26 Production Wells No Violations Water in the tank battery was tested using Quantab chloride test strips. A high range and low range strip were used at different locations. The high range strip indicated 360 ppm chloride and the low range indicated 232 ppm chloride. The salt content of the tank battery is decreasing. No leakage was observed from equipment in the tank battery.
0134017356 2016-08-01 Production Wells No Violations The fluid in the tank battery has been cleaned up. The tank heater was shut off and no gas was venting from it. Gas was audibly leaking from the well head. There is a fluid leak at the well head from the solvent injector. The oil and absorbent around the well is partially cleaned up. There is a pile of black mucky material next to the pump jack. The third tank from the well in the tank battery is unhooked from the flowline. The tank was empty. The loadout line and a vent line connected to the middle tank were still in place. The loadout line to the first tank is unhooked. The clear plastic hose was removed from the dike and is coiled on top of it. The operator needs to locate the tank leak and repair or replace the leaking tank. The pumper told Tom Benko that a tank overflowed over the winter due to the vent line freezing up between the middle and third tanks. They also replaced the first tank closest to the well.
0344200666 2007-06-21 Production Wells No Violations Inspect well and locations. New tank battery has been constructed, three 210 bbl tanks are constructed within a dike area lined with a liner. The original tank battery at the house has been removed and cleaned up. Site looks good. Well has been serviced recently and has newer stuffing box with a stuffing box leak detector. Although the stuffing box appears to have a slow leak. Well head area heavily stained with oil. Well in production during inspection.
0461171197 2016-07-28 Production Wells No Violations The operator has placed absorbent around the well. Oil is cleaned up. The pumper was advised to remove the absorbent material. There is still water in the tank battery. There hasnt been any rain in a significant time. The field around the location is dry; there are no puddles. Soil in the field is powdery and produces dust. Water within the tank battery registered 9.2 on a high range Quantab strip which is above the scale on the Quantab chart. The chart stops at 9.0 or 6482 ppm chloride. A 1 inch diameter clear vinyl hose was located over the containment berm with one end submerged in the fluid. Staining and dead grass were found at the other end of the hose outside containment. The hose was not discharging at the time of inspection. No sump pump has been installed in the dike as the pumper stated would be done. The pumper was contacted and stated he carries the pump with him and pumps the dike when he tends the well. No leaks are visible from any of the tanks or lines. The pumper blamed water on rainfall, which is not supported by evidence in the surrounding area and the salt content of water in the containment. The tank heater was venting gas through the burner tube in the 200 barrel tank closest to the well. The burner was not lit. The well was pumping during inspection. The flowline valve to the tank the burner was under was closed.
0625827014 2010-11-08 Production Wells No Violations Inspect well. Site ok.
0641890248 2016-06-23 Production Wells No Violations The pumper requested to meet with the inspector. Oil around the well has been cleaned up with peat sorb. Heavy rain fell on the area overnight. No free oil was observed. The pumper stated they had pumped out the tank battery but rainfall filled it up again. The pumper stated they would be installing a sump pump in the containment area and plumbing it into the water tank.
0696949705 2016-10-12 Production Wells No Violations All 3 tanks in the tank battery have fluid in them. The well was pumping during inspection. Water has been vacuumed from the dike. Remaining fluid measured 7.8 on the high range quantab for chlorides. This is down slightly from the previously measured values of 9.2. There is an audible leak of gas from the wellhead. There is fluid around the wellhead. A 2 inch line in the tank battery was observed dripping brine slowly. The well has not been brought into compliance with the previously issued compliance notice yet.
0842297970 2006-04-05 Production Wells No Violations Newly constructed tank battery with dike and liner and limestone on liner. Holds 30 210 Bbl tanks. Well is pumping and recently reworked. Small unlined pit open. Took 3 photos. Bob Atha showed up while I was there. Asked him to get pit emptied and filled in. He called Paul Mullins. Paul to be there in 1.5 hrs. to empty pit.
0909587630 2013-12-15 Brine Hauler No Violations Collected brine sample from Mullins Energy Service UIC 25-538 Truck. Brine will be delivered to 3411721901 Tretow #2 SWIW # 48.
1011610360 2009-12-14 Production Wells No Violations Inspect well and location. Site ok.
1035817064 2002-10-28 Production Wells Violations Noted Well inspection. Stuffing box on well has leaked. Release of petroleum onto surface at well head and onto access road. Impacted area approximately 30 feet by 30 feet. Identification is not legible at well site. Tank battery inspection. Identification is present and legible at tank battery. Buried steel tank used for salt water storage. Older style tank, manufactured with rivets. Tank integrity is unknown. Catholic protection is not present. Debris is present on the top of the tank. Not able to determine the presence of an interior tank coating. Overall site conditions are marginal, oil staining inside the dike field and oil staining outside dike field near load out piping. Probable brine staining of drive area along diked field.
1057132295 2017-05-26 Production Wells No Violations Rain water has accumulated in the tank containment area and needs to be pumped out again. Cleanup of the wellhead remains to be completed to satisfy the compliance notice.
1152978733 2003-05-29 Production Wells No Violations Inspect Site, well and tanks. Pump jack is running. Tank battery. The production unit is leaking at several locations. Small amount of oil is accumulating on the ground.
1176402004 2017-01-09 Production Wells No Violations No leaks observed during inspection. The well was being pumped. Water in the tank battery is frozen and couldnt be tested.
1405257914 2016-08-09 Production Wells No Violations The water level in the dike has risen since the pumper vacuumed it out with the water truck. The water tested 9.2 for chlorides on a high range Quantab. The chloride level has not diluted from the previous test prior to the pumper removing the water. A fitting on the 2 inch line connecting the tanks at the rear of the tank battery was dripping slowly. The third tank from the well has fluid in it about 4 feet deep. The dike is lined. The burner is shut off and is not venting gas. The vinyl hose has been removed from the tank battery. Oil around the wellhead has been cleaned up. The leak in the tank battery needs to be repaired.
1427134261 2015-03-23 Production Wells No Violations ID posted. The well is equipped with a pump jack and is in production. There are 3 200 Bbl oil tanks in the tank battery. The area inside the dyke is stained with crude however there is no fluid present. The stuffing box on the well is leaking. The operator was contacted to repair the well head. Bob Atha, 614-206-5394 is the contact for the company. He is sending the pumper out to repair the stuffing box and clean up oil around the well.
1465318621 2016-06-07 Production Wells Violations Noted ID is posted. The well is equipped with a pump jack, rods and tubing and is in production. There is oil on the ground at the wellhead. There is oil floating on a puddle adjacent to the well and the soil is stained black about 15 to 20 feet from the well. The operator was previously advised following inspection in 2015 to repair the leak at the wellhead and clean up spilled oil. The wellhead is repaired. Cleanup needs to be completed. The tank battery has water in the dike and there is oil staining on the ground inside the containment area. The tank battery is lined. The operator is heating the tank that fluid is being produced into. The operator was contacted and advised to turn off the tank heater while the well is being produced. Clean up contaminated soil and spilled fluid at the wellhead and tank battery by July 7, 2016.
1493643254 2017-04-18 Brine Hauler No Violations Inspect Mullins Energy Service Truck UIC #25-538. Truck and log are in compliance. Collect water sample TSB-122 from truck for chemical analysis. The source water is from the Beer #3 API# 3413920539. The Specific Gravity was measured at 1.200 units.
1499883270 2017-07-12 Production Wells No Violations Kevin Mullins contacted the inspector to advice that they had a service rig on the well. On arrival, the rig was on the well and rods had been pulled. No rig personnel were on site.
1499954037 2017-07-13 Production Wells No Violations The service rig is on the well. The well has been serviced and returned to operation. Kevin Mullins was on site during inspection. The wellhead rubbers were replaced and the stuffing box was replaced. The wellhead leakage has been repaired. Water has been pumped from the tank battery and no leaks were observed. Paraffin and fluid around the well have been cleaned up. The well is in compliance.
1550161154 2019-02-12 Production Wells No Violations Inspected wellsite area. Well was producing at the time of this inspection. Six inches of water was discovered in the dike area and was tested for chlorides. Test determined no chlorides in the water at the time of this inspection. Identification is posted at wellsite.
1567535524 2019-9-3 0:00:0 PW No Violations
1619222885 2016-12-01 Production Wells No Violations The well is in production and was pumping during inspection. Water is accumulated in the tank battery dike and is nearly up to the burner tubes in the tanks. Water tested approximately 1000ppm chlorides (4.9 on high range Quantab test strip). There is a sheen on the water in the tank battery and there are dirty absorbent pads in the dike as well. No leakage was observed during the inspection from exposed lines in the tank battery. Gas is audibly leaking from the well head. Kevin Mullins, contract pumper, was contacted following inspection. He was advised to remove fluid and pads from the containment dike and to work with the owner of the well to investigate the source of brine leakage in the dike. He was also advised that the owner will have to install a flare to continue venting of gas at the well site. The compliance notice remains unresolved at this time.
1633597489 2017-02-23 Production Wells No Violations Water in the tank battery dike was tested for chlorides. The water registered 7.6 on a high range Quantab test strip, which equals 3033 ppm chloride.
1712282844 2009-07-14 Production Wells No Violations Inspect well. Site ok. Operator on site during inspection.
1739328299 2018-01-30 Production Wells No Violations The well is equipped with a pump jack, rods and tubing and is in production. There are 3-200 barrel tanks in the tank battery. ID is posted at the tanks.
1795775980 2003-04-30 Production Wells No Violations Inspect well site and tank battery site. Well site ok. Recently brought in pea gravel to raise the level of the drive due to water sitting in drive. Covered over previous spill / release of petroleum products. A 100 bbl tank is located on site at n40.78646,w82.606836.

The main tank battery has three 210 bbl tanks. Properly identification. A ~1000 gallon tank is buried in the ground.

1973149656 2017-05-15 Production Wells No Violations The pumper contacted the inspector on Saturday and stated the tank battery had been cleaned up. Water and brine have been removed from the containment area of the tank battery. Parrafin and fluid around the wellhead need to be cleaned up to satisfy the compliance notice. No leakage was observed during inspection.
2023248825 2013-01-09 Production Wells No Violations Inspect well and tanks. Well is in production and capable. Site looks ok.
641890248 2016-6-23 0:00: PW No Violations 3.00
696949705 2016-10-12 0:00 PW No Violations 2.00
842297970 2006-4-5 0:00:0 PW No Violations
909587630 2013-12-15 0:00 BH No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1035817064 US-OH-100140 2002-10-28 Well operation causing pollution and contamination
1465318621 US-OH-113453 2017-08-14 9-1-07 Well operation causing pollution and contamination
1465318621 US-OH-113454 2017-08-14 9-9-05(A)9 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[8]

References