If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-139-20719 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.59,"lon":-82.49,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Richland | |
Municipality: Jefferson Township | |
Operator Name: ROMAN WELL SERVICES INC | |
Well Pad ID: | |
Farm/Lease Name: MCCONKIE | |
License Status: Final Restoration | |
License Date: 2006-11-13 | |
Spud Date: 2000-08-31 | |
Spud Drilling Contractor: G & H DRLG | |
Final Drill Date: 2000-09-18 | |
Well Total Depth: 2443.00 ft | |
Configuration: Vertical | |
Latitude: 40.590000 | |
Longitude: -82.490000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2000-08-23 | 2521 ROMAN WELL SERVICES INC Proposed Formation CLINTON/TREMPEALEAU Issued Date 8/23/00 Expired Date 8/23/01 6:00:00 AM |
Original Spud | 2000-08-31 | RBDMS Rec |
Completed | 2000-09-18 | RBDMS Rec |
Reached Total Depth | 2000-09-18 | RBDMS Rec |
Completion Report Received | 2000-12-08 | RBDMS Rec |
APP | 2005-10-26 | Proposed Formations:CLINTON, Issued Date:10/26/2005, Expired Date:10/26/2006 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
APP | 2006-11-13 | Proposed Formations:CLINTON, Issued Date:11/13/2006, Expired Date:11/13/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2006-11-21 | RBDMS Rec |
Construction Permit Expires | 2007-11-13 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2001-02-08 | 2286 | 2390 | 16 |
2286 | 2390 | 16 | |
2286 | 2390 | 16 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 900 Bbl | 20000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
2001 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
2002 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
2003 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
2004 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
2005 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
2006 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
2007 | ROMAN WELL SERVICES INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
2001 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
2002 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
2003 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
2004 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
2005 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
2006 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
2007 | ROMAN WELL SERVICES INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1201594229 | 2003-10-22 0:00 | PW | No Violations | |
-280697419 | 2005-1-20 0:00: | PW | No Violations | |
-315623359 | 2003-7-14 0:00: | DD | No Violations | |
-981682032 | 2005-4-12 0:00: | PW | No Violations | |
0280697419 | 2005-01-20 | Production Wells | No Violations | Inspect well with Jeff Fry. No Identification. Pump jack is now set on well and set up to test well. Fluids are diverted to driller tank on site, empty. No production line has been laid. Operator has had time to evaluate this well. |
0315623359 | 2003-07-14 | Drill / Deepen / Reopen | No Violations | No activity. Field should be dry enough to move in. |
0377264611 | 2003-07-08 | Drill / Deepen / Reopen | No Violations | Informed that activity to put well into production was supposed to initiate today. No activity. Location may be too wet due to severe rain storms today and over weekend. |
0664064177 | 2004-03-26 | Production Wells | No Violations | Inspect well. Well has been completed and well head piping connected. Production line has not been installed. Well shut in. Frac tank on site. |
0891586756 | 2003-07-08 | Drill / Deepen / Reopen | No Violations | Inspect site. No activity. Site too wet. |
0981682032 | 2005-04-12 | Production Wells | No Violations | Inspect well. Setup for well has not changed. No activity. Not capable of production. |
1037814513 | 2002-11-20 | Production Wells | Violations Noted | Well inspection. Well incapable of production. Well string including tubing and rods on ground adjacent to well head. Well head open hole with 4.5 inch casing at surface. No production lines and no tanks to well. Digital pictures of site tank, five(5). Preliminary restoration is rough graded. No identification present.
Note: Discussed Well with Dennis Weese 12-1-02. This well has not been completed as of this date. The well was drilled to the total depth. The four(4) inch long string was installed with a cement shoe and cemented in place. The well requires to be shot and swabbed. NOTE: This report was resolved due to a data base issue with the violations the violation was re created and issued on 3-10-03. Tsb.
|
1047314650 | 2003-01-20 | Production Wells | Violations Noted | Well inspection. Well incapable of production. Well string including tubing and rods on ground adjacent to well head. Well head open hole with 4.5 inch casing at surface. No production lines and no tanks to well. Digital pictures of site tank, five(5). Preliminary restoration is rough graded. No identification present.
Note: Discussed Well with Dennis Weese 12-1-02. This well has not been completed as of this date. The well was drilled to the total depth. The four(4) inch long string was installed with a cement shoe and cemented in place. The well requires to be shot and swabbed. 3-10-03: The well is required to be placed into production or plugged and abandoned by the remedy date. 1/7/07: well plugged. |
1059742771 | 2003-07-31 | Drill / Deepen / Reopen | No Violations | Inspect Site Activities. Swab rig on hole. Tubing placed in well. Sucker rods being placed in hole during inspection. |
1062348724 | 2002-11-20 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1037814513 Well inspection. Well incapable of production. Well string including tubing and rods on ground adjacent to well head. Well head open hole with 4.5 inch casing at surface. No production lines and no tanks to well. Digital pictures of site tank, five(5)
1/2/07: well plugged. |
1089740878 | 2004-07-13 | Production Wells | No Violations | Well is equiped with pumpjack. Line hooked up to an old drilling tub. Well has no ID and is not pumping at this time. |
1111156250 | 2005-03-18 | Administrative Inspection | No Violations | I received a call this morning from Bob McConkie regarding the Dennis Weese well. He stated Dennis pumped on the well for several days a year ago and has not worked the well since. He would like the well plugged to get his field back. |
1128350616 | 2005-09-30 | Production Wells | No Violations | Inspect Well for Tom Tugend, with Jeff Fry. No change at well head. Well shut in. No ID, Incapable of produciton, Pump jack. Tubing runs to a flat tank. Well head overgrown. Dennins Weese Has previously indicated he would plug well. |
1201594229 | 2003-10-22 | Production Wells | No Violations | Inspect Well site. Well has been serviced. Tubing and rods have been installed in well. Well head piping has been completed. No pump jack is on site or set up. No tanks or production units at location. Production line from well head to gathering line has not been installed or completed. |
1801380439 | 2006-12-07 | Final Restoration | No Violations | Inspect location. Well plugged, site graded. Final restoration ok. |
377264611 | 2003-7-8 0:00:0 | DD | No Violations | |
664064177 | 2004-3-26 0:00: | PW | No Violations | |
891586756 | 2003-7-8 0:00:0 | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1037814513 | US-OH-100021 | 2002-11-20 | Failure to restore land surface within 9 mos. (CHANGE) (REPLACE) | |
1037814513 | US-OH-100022 | 2002-11-20 | Failure to legibly identify well | |
1037814513 | US-OH-100023 | 2002-11-20 | Well shall be plugged | |
1047314650 | US-OH-100749 | 2002-11-20 | Failure to restore land surface within 9 mos. (CHANGE) (REPLACE) | |
1047314650 | US-OH-100750 | 2002-11-20 | Failure to legibly identify well | |
1047314650 | US-OH-100751 | 2003-03-10 | Well shall be plugged | |
1062348724 | US-OH-101232 | 2002-11-20 | Failure to restore land surface within 9 mos. (CHANGE) (REPLACE) | |
1062348724 | US-OH-101233 | 2002-11-20 | Failure to legibly identify well | |
1062348724 | US-OH-101234 | 2002-11-20 | Well shall be plugged |
For data sources see[9]