X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-139-60273

Well Details

Well ID: 34-139-60273
Loading map...
Country: United States
State: Ohio
County: Richland
Municipality: Worthington Township
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: MUSKINGUM W C DISTRICT
License Status: Plugged and Abandoned
License Date: 2016-07-21
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.630000
Longitude: -82.370000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2016-07-21 Proposed Formations:CLINTON SANDSTONE, Issued Date:7/21/2016, Expired Date:7/21/2018 12:00:00 PM, Drilling unit acres:2417.55, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-02-10
Construction Permit Expires 2018-07-21

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1020797954 2016-5-2 0:00:0 PB No Violations 0.50
-111383407 2017-5-31 0:00: PB No Violations 2.50
-1410734142 2017-6-27 0:00: PB No Violations 1.00
-1427169652 2017-5-25 0:00: PB No Violations 2.00
-1495792987 2017-6-6 0:00:0 PB No Violations 4.00
-1778121340 2016-3-2 0:00:0 PB No Violations 2.00
-1848300303 2016-3-21 0:00: PB No Violations 3.00
-301376642 2017-6-1 0:00:0 PB No Violations 2.00
-341523726 2017-4-28 0:00: PW No Violations 1.00
-417528158 2017-6-14 0:00: PB No Violations 1.50
-817022218 2017-3-23 0:00: PW No Violations 3.00
0111383407 2017-05-31 Plug / Plug Back No Violations Columbia Gas service rig is rigged up with a power swivel and they are drilling to clean out the hole. Drilling was at 975 feet on arrival. 5 drill collars were ran during inspection and no resistance was encountered. Some wood chips are coming back in fluid returns. The operator is drilling with a 7.875 inch bit. The BOP was tested prior to inspector arrival. The BOP passed testing at 1100 psi. Field pressure is 750 psi based on gauge of well 34-139-20135.
0301376642 2017-06-01 Plug / Plug Back No Violations Columbia Gas service rig is cleaning out the well with a 7.875 inch bit. Drilling is proceeding on fluid. Two joints of drill pipe were ran in the hole during inspection. Drilling is at 1416 feet in the big lime. A small gas kick was reported at the top of the lime. Drilling is producing minimal cuttings. The rig operator believes the cuttings are from the sides of the hole. Drilling is proceeding with little resistance.
0341523726 2017-04-28 Production Wells No Violations Columbia Gas is building an access road to the well location. They have laid down mud mats with liner and curbing to surface the road.
0402891222 2017-05-17 Production Wells No Violations Whan Incorporated is on site building location. Subcontractors are installing liner and plastic mats on the work area. Columbia is planning to move in on Friday.
0417528158 2017-06-14 Plug / Plug Back No Violations The well has been cut off and Columbia is moving equipment off location. The cellar is full of rain water.
0817022218 2017-03-23 Production Wells No Violations Columbia Gas Transmission, Muskingum Watershed and contractor representatives met at the well location to discuss work to access, reopen and replug the well. The well is leaking gas from the storage field. Columbia Gas installed a vent riser over the well for safety after receiving a gas leak complaint last year. Columbia Gas obtained a plug permit for the well to reopen and replug the well. They have received approval from the US Army Corps of Engineers to build location. Surface work limits have been staked and flagged. They are going to begin clearing trees at the location prior to an April 1 deadline. Plugging will likely start in June due to flooding potential of the location in April and May.
0853897078 2017-05-22 Plug / Plug Back No Violations Columbia Gas is rigging up the service rig on the well to reopen and replug the well due to leakage.
0862839726 2017-06-02 Plug / Plug Back No Violations 7 inch casing top was encountered at 1634 feet. Wait on rig to run 6.25 inch bit to the 7 inch casing and attempt to drill ahead. The bit entered the casing with no resistance. An obstruction was encountered below the anticipated 7 inch seat. Wood chips came up in the fluid returns. The rig was able to continue drilling to 1830 feet. Rock fragments were observed in the returns. Drilling stopped and the hole was circulated to clean it out at 1830. Drilling will resume Monday.
1020797954 2016-05-02 Plug / Plug Back No Violations The vent stack is stable on the well. No leakage was observed at ground level. Columbia Gas stated they are going to get a permit to reopen and plug the well this summer.
1410734142 2017-06-27 Plug / Plug Back No Violations Whan Incorporated is on site restoring the well location and access road. The rig location has been topsoiled and finish graded. The area has been disced from the well up to the stream crossing. The temporary bridge has been removed from the crossing. Whan is removing timber mats from the access road.
1427169652 2017-05-25 Plug / Plug Back No Violations 8.625 inch surface casing was installed and cemented in the well. No leakage was observed outside the casing. No one is working on the rig today. Mac Oil delivered a fluid tank to the location.
1490791511 2017-03-28 Production Wells No Violations The contractor for Columbia Pipeline Group has begun clearing trees to access the well.
1491485825 2017-03-31 Storage Well No Violations Columbia Gas has completed cutting down trees within the marked work area associated with the well. The well is leaking gas from the storage field and Columbia is going to reopen and replug the well.
1495792987 2017-06-06 Plug / Plug Back No Violations Arrive 930 AM. Drilling is proceeding against an obsruction in the well at 2340 feet. Rock fragments are coming back in the drill mud. Returned to job at 2:00 with surveyor to take location on well. The rig tripped out of the hole to reduce bit from 6.25 to 4.75 inch at 2372 feet. The original hole reduced size.
1496320208 2017-05-30 Plug / Plug Back No Violations The rig crew rigged up the BOP and they are setting up dumpsters for drill cuttings. The BOP pressure test was anticipated in the afternoon, however, the rig crew was waiting on additional equipment and the test was delayed until tomorrow.
1497289081 2017-06-12 Plug / Plug Back No Violations The Columbia Gas service rig ran drill pipe to set Berea and surface plugs. The lime plug was tagged at 1250 feet. The operator pulled up to 631 feet and set a 100 sack plug at the Berea sand. The drill pipe was pulled above cement and the well was filled to surface. Cement returned to surface.
1498737258 2017-06-28 Final Restoration No Violations The well location and access road have been topsoiled and finish graded. The disturbed area has been seeded with a wildlife seed mix per the surface owners request. All equipment and road materials have been removed. Whan Incorporated personnel were on site during inspection. Final restoration is approved. No pipeline was found around the well. The well was not connected at the time it was replugged.
1634238135 2017-05-24 Plug / Plug Back No Violations Cement a 8 5/8 inch surface casing to protect the groundwater for clean out and plugging of the well. Pump 115 sacks of cement, cement returns were observed prior to releasing wiper plug for displacement. Good cement returns.
1778121340 2016-03-02 Plug / Plug Back No Violations A gas leak was reported to Columbia Gas. They determined they have no pipeline in the area. Terry VanSickle and Brent Criser of Columbia requested an inspection to determine if there is a historic well at the location. We examined the leak. The well location is within the tailwater of the Pleasant Hill Lake and dam. The area is wet woods and the well is below grade with water laying on the ground. No oil or brine was evident. Gas is bubbling through the water. Columbia installed orange safety fence at the location. The Division had no record of the well; permitting staff assigned the API number. A metal detector and probe revealed the presence of casing at the leak location. Historic well maps indicate a Clinton well at the location. There is no further information on the well in Division or Columbia Gas records. Columbia is planning to expose the top of the well and install a vent stack on it. Muskingum Watershed is the surface owner and they are preparing an agreement for Columbia to access the well. Columbia obtained a gas sample to determine if it is from the storage field. If so they want to plug the well; if not it will need orphan referral.
1781957481 2017-05-23 Plug / Plug Back No Violations The Columbia Gas Service Rig is on the well. The well was cleaned out to a depth of 313 feet and Columbia is going to set and cement 8.625 inch surface casing in the morning. The well cleaned out easily to 280 feet where resistance was encountered and wood chips returned in the drilling fluid.
1848300303 2016-03-21 Plug / Plug Back No Violations Columbia Gas had a contractor on site to dig up the well. 10 inch casing was exposed with a mini excavator. Gas and water are coming up the inside of the casing. No leakage outside the old casing was observed. John Watkins and Brad Janssen of MWCD arrived on site. A vent stack consisting of N-12 culvert pipe was installed over the 10 inch and the hole was backfilled. Water from the well is seeping out between the vent pipe and old casing. Columbia doesnt have gas analysis results yet.
1881197310 2017-06-07 Plug / Plug Back No Violations The rig is drilling ahead to total depth of the original well on 4.75 inch bit. Rock fragments are coming back in the cuttings. Drilling is slow. The operator called following inspection to state total depth was reached at 2474 feet.
1973674663 2017-06-08 Plug / Plug Back No Violations The operator requested inspection to witness setting the bottom plug and lime plug. Cement was pumped by Petroset. See the plug report for details.
402891222 2017-5-17 0:00: PW No Violations 0.50
853897078 2017-5-22 0:00: PB No Violations 1.50
862839726 2017-6-2 0:00:0 PB No Violations 7.00

For data sources see[3]

References