Well ID: 34-151-22594 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.87,"lon":-81.15,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Washington Township | |
Operator Name: HALL & HORNING SERV INC | |
Well Pad ID: | |
Farm/Lease Name: VAN WAGENEN UNIT | |
License Status: Producing | |
License Date: 2004-05-11 | |
Spud Date: 1974-12-12 | |
Spud Drilling Contractor: | |
Final Drill Date: 1974-12-20 | |
Well Total Depth: 5235.00 ft | |
Configuration: Vertical | |
Latitude: 40.870000 | |
Longitude: -81.150000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1974-12-12 | |
Completed | 1974-12-20 | |
Reached Total Depth | 1974-12-20 | |
CO | 1981-11-19 | 935 HUTCHESON RH/BoCOR PROD GeoDate 11/19/81 |
CO | 1991-07-19 | 935 HUTCHESON RH/BoCOR PROD GeoDate 7/19/91 |
Unknown | 1991-07-19 | Issued Date 7/19/91 Expired Date 7/18/92 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date |
APP | 1999-06-22 | Proposed Formations:CLINTON, Issued Date:6/22/99, Expired Date:6/21/00 6:00:00 AM, Drilling unit acres:75.01, Proposed Well Type:OG, Proposed Well Class: |
Change of Owner | 1999-09-20 | Operator changed from 935, HUTCHESON RH/BOCOR PROD to 2512, MILLER WILLIAM S INC |
Change of Owner | 1999-12-21 | Operator changed from 2512, MILLER WILLIAM S INC to 3847, HALL & HORNING SERV INC |
APP | 2004-05-11 | Proposed Formations:CLINTON, Issued Date:5/11/2004, Expired Date:5/11/2005 6:00:00 AM, Drilling unit acres:75.01, Proposed Well Type:OG, Proposed Well Class: |
Construction Permit Expires | 2005-05-11 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5058 | 5185 | 18 |
5058 | 5185 | 18 | |
5058 | 5185 | 18 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 103000 Gal | 77000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | YEI INC | 155.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | YEI INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1270725459 | 2014-2-6 0:00:0 | PW | No Violations | 2.00 |
-1617670114 | 2014-4-3 0:00:0 | PW | No Violations | 2.00 |
-1998955998 | 2017-10-27 0:00 | PW | No Violations | 0.70 |
-683074555 | 2015-10-13 0:00 | PW | No Violations | 1.50 |
0055545925 | 2017-07-12 | Production Wells | No Violations | I conducted an order follow-up inspection on this well for Chiefs Order # 2017-79 issues 03-07-17. The well is not plugged as required by the order. The wells master valve is closed and it has a swage with a gauge connection. There are flowlines above ground around the well area. The well is not legibly identified. The last production report submitted was in 1984. No tank battery has been located at this time. |
0364965353 | 2016-11-29 | Production Wells | No Violations | A compliance notice follow-up inspection was done on 11-29-2016 and as noted in previous inspection report the well is incapable of production. The initial Compliance Notice was issued on 04-04-2014 for the following non-compliance issue with a remedy required date of 10-03-2014:
|
0528540456 | 2017-04-19 | Production Wells | No Violations | I conducted a Chiefs Order Follow-up inspection on this well for Chiefs Order 2017-79 issued 03-07-2017. The well is not plugged as ordered. The wells master valve is closed and it has a swage with a gauge connection. There are flowlines above ground around the well area. The area around the wellhead is overgrown with vegetation. No tank battery has been located at this time. The well is not legibly identified. The last production report submitted was in 1984. This well is currently incapable of production. |
0683074555 | 2015-10-13 | Production Wells | No Violations | |
0738548505 | 2018-01-10 | Production Wells | No Violations | I conducted an order follow-up inspection on this well for Chiefs Order # 2017-79 issues 03-07-17. The well is not plugged as required by the order. The wells master valve is closed and it has a swage with a gauge connection. There are flowlines above ground around the well area. The well is not legibly identified. The last production report submitted was in 1984. No tank battery has been located at this time. I called 330-472-1389 and spoke with Randy Hall (owner). |
1163051206 | 2018-09-18 | Production Wells | No Violations | My inspection for Chiefs Order 2107-79 Plugging Required has not been complied with. The well is not plugged has required by the Order. I phoned Randy Hall (330-472-1389) and he advised his bond has been pulled . |
1270725459 | 2014-02-06 | Production Wells | No Violations | I was on location to perform an inspection on this well. The well lease road has been abandoned and overgrown. There is no associated tank battery for this well in the area. The well currently consist of casing sticking out of the ground with a shut in casing valve. There are flow lines throughout the area above ground, rusted and broken. There is no identification on the well. Production for this well has not been shown since 1984. Permits to plug and abandon this well have been issued in 1991, 1999 and 2004 but the well has not been plugged. |
1468850391 | 2016-07-12 | Production Wells | No Violations | A compliance notice follow-up inspection was done on 07-12-2016 and as noted in previous inspection report the well is incapable of production. The initial Compliance Notice was issued on 04-04-2014 for the following non-compliance issue with a remedy required date of 10-03-2014:
|
1484761823 | 2017-01-17 | Production Wells | No Violations | I conducted a compliance notice follow up inspection on this well. A compliance notice was issued to plug the well on 4/4/2014. The well has not been plugged. The wells master valve is closed and it has a swage with a gauge connection. There are flowlines above ground around the well area. The area around the wellhead is overgrown with brush. No tank battery has been located at this time. The well is not legibly identified. The last production report submitted was in 1984. This well is currently incapable of production. |
1547552463 | 2018-11-09 | Production Wells | No Violations | My inspection for Chiefs Order 2107-79 Plugging Required has not been complied with. The well is not plugged has required by the Order. I phoned 330-472-1389 and left a message for Randy Hall (Owner) for a return call. |
1617670114 | 2014-04-03 | Production Wells | Violations Noted | I was on location with supervisors Tom Hill, Rick Anderson and inspector Jim Bucksar. During our inspection we found a wellhead with no production or processing equipment. The wellhead has open casing with a shut in valve. Flow lines for the well are torn up and sticking out of the ground. The area around the wellhead is overgrown with brush. There is no associated tank battery for this well and a lease road could not be identified. Production has not been shown since 1984. This well is incapable of production and must be plugged within 180 days (10/3/2014). |
1998955998 | 2017-10-27 | Production Wells | No Violations | I conducted an order follow-up inspection on this well for Chiefs Order # 2017-79 issues 03-07-17. The well is not plugged as required by the order. The wells master valve is closed and it has a swage with a gauge connection. There are flowlines above ground around the well area. The well is not legibly identified. The last production report submitted was in 1984. No tank battery has been located at this time. I called 330-472-1389 and spoke with gentleman who claimed he doesnt own anymore wells and Hall & Horning are out of business. |
364965353 | 2016-11-29 0:00 | PW | No Violations | 1.50 |
528540456 | 2017-4-19 0:00: | PW | No Violations | 1.00 |
55545925 | 2017-7-12 0:00: | PW | No Violations | 0.70 |
738548505 | 2018-1-10 0:00: | PW | No Violations | 0.70 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1617670114 | US-OH-115888 | 2014-04-24 | Well shall be plugged |
For data sources see[9]