34-151-22903

Well Details

Well ID: 34-151-22903
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Tuscarawas Township
Operator Name: WEFLER WARREN H
Well Pad ID:
Farm/Lease Name: WEFLER W
License Status: Final Restoration
License Date: 2015-08-06
Spud Date: 1978-12-11
Spud Drilling Contractor:
Final Drill Date: 1978-12-19
Well Total Depth: 4258.00 ft
Configuration: Vertical
Latitude: 40.760000
Longitude: -81.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1978-10-03 182 BELDEN & BLAKE CO GeoDate 10/3/78
Original Spud 1978-12-11
Completed 1978-12-19
Reached Total Depth 1978-12-19
CO 1996-05-09 1995 WEFLER WARREN H GeoDate 10/3/78
APP 2015-08-06 Proposed Formations:CLINTON, Issued Date:8/6/2015, Expired Date:8/5/2017 12:00:00 PM, Drilling unit acres:80, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2015-08-17
Construction Permit Expires 2016-08-05
Record Last Modified 2017-02-10

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4084 4160 15
4084 4160 15
4084 4160 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 80000 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION 2058.00 37.00 0
1985 BELDEN & BLAKE CORPORATION 1498.00 16.00 0
1986 BELDEN & BLAKE CORPORATION 1724.00 37.00 365
1987 BELDEN & BLAKE CORPORATION 1582.00 83.00 365
1988 BELDEN & BLAKE CORPORATION 1614.00 0.00 366
1989 BELDEN & BLAKE CORPORATION 1144.00 0.00 360
1990 BELDEN & BLAKE CORPORATION 1099.00 40.00 356
1991 BELDEN & BLAKE CORPORATION 638.00 0.00 365
1992 BELDEN & BLAKE CORPORATION 186.00 0.00 366
1993 BELDEN & BLAKE CORPORATION 386.00 0.00 365
1994 BELDEN & BLAKE CORPORATION 175.00 0.00 302
1995 BELDEN & BLAKE CORPORATION 126.00 37.00 95
1996 BELDEN & BLAKE CORPORATION 70.00 0.00 366
2008 WEFLER WARREN H 0.00 0.00 0
2009 WEFLER WARREN H 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION Brine 0 0
1985 BELDEN & BLAKE CORPORATION Brine 16 0
1986 BELDEN & BLAKE CORPORATION Brine 28 365
1987 BELDEN & BLAKE CORPORATION Brine 10 365
1988 BELDEN & BLAKE CORPORATION Brine 0 366
1989 BELDEN & BLAKE CORPORATION Brine 33 360
1990 BELDEN & BLAKE CORPORATION Brine 0 356
1991 BELDEN & BLAKE CORPORATION Brine 0 365
1992 BELDEN & BLAKE CORPORATION Brine 0 366
1993 BELDEN & BLAKE CORPORATION Brine 0 365
1994 BELDEN & BLAKE CORPORATION Brine 0 302
1995 BELDEN & BLAKE CORPORATION Brine 59 95
1996 BELDEN & BLAKE CORPORATION Brine 0 366
2008 WEFLER WARREN H Brine 0 0
2009 WEFLER WARREN H Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1158858343 2014-10-30 0:00 PW No Violations 2.50
-1829844892 2015-8-13 0:00: PB No Violations 3.50
1158858343 2014-10-30 Production Wells Violations Noted I was on location to perform an exempt pre-transfer inspection for this well. Currently the well has a 4.5 gate valve, and a swage to a 2 diameter bull plug with a non-functioning pressure gauge. This well has no production control equipment and is not capable of production. There is no domestic supply equipment present. The 8.625 diameter casing is buried and not accessible. There are no visual integrity issues with the wellhead. The tank battery contains a 210bbl production tank, a vertical separator and a completely full brine vault that needs to be emptied. The tank battery is heavily overgrown, and does not contain a legible I.D. sign. This well does not meet the definitional requirements for an Exempt Domestic Well, per 1509.01(X). This well is not capable of production and has not shown any production since 1996. This well shall be plugged per Ohio Revised Code 1509.12(B) within 180 days.
1405359713 2015-10-19 Final Restoration No Violations I was on location to check the status of final restoration. The location has been reclaimed and vegetation has been established. All of the production equipment has been removed and there are no signs of the well leaking. A landowner waiver has been received to waive the removal of the in-ground brine storage tank which has been cleaned out and crushed. Also waived is the removal of the 2 diameter flow line which will be left in place. A plugging report is on file for this well. At this time final restoration has been passed.
1439573192 2015-08-14 Plug / Plug Back No Violations I was on location to witness the setting of the Big Lime Plug for this well. The Bishop Well Service rig ran 2822 of 2.375 diameter tubing into the well. Petroset circulated the wellbore and pumped a 75sk 300 Class A 2% gel plug. The plug was displaced with 10bbls of fresh water. The rig will pull tubing to the bottom of the surface plug point and shut the well in for the weekend. Plugging will continue on 8/17/2015.
1440510761 2015-08-17 Plug / Plug Back No Violations I was on location to witness the plugging of this well by Gonzoil and Bishop Well Services. The rig ran 836 of 2.375 diameter tubing into the well. Petroset circulated the wellbore and pumped a 50sk 200 Class A 2% gel plug to cover the bottom of the surface casing. The plug was displaced with 2.5bbls of fresh water. The tubing was pulled to 200 and a 60sk Class A 2% gel cement plug was circulated to surface. The tubing was pulled from the well and cement did not fall. The casing will be cut below grade and a plate with the API# will be fixed on the well. This well has been successfully plugged and at this time the compliance notice for this well has been closed.
1829844892 2015-08-13 Plug / Plug Back No Violations I was on location to witness the setting of the bottom plug for this well. The Bishop Well Service rig ran 4093 of 2.375 diameter tubing into the well. Petroset circulated the wellbore and pumped a 30sk Class A 2% gel bottom plug. The plug was displaced with 15bbls of fresh water. The rig will rip casing and pull it from the well due to a hole in the 4.5 diameter casing.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1158858343 US-OH-104204 2015-08-26 Failure to legibly identify well
1158858343 US-OH-104205 2015-08-26 Well shall be plugged

For data sources see[9]