X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-151-23342

Well Details

Well ID: 34-151-23342
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Paris Township
Operator Name: PDL SERVICES INC
Well Pad ID:
Farm/Lease Name: KIKO
License Status: Producing
License Date: 1994-11-16
Spud Date: 1981-02-03
Spud Drilling Contractor:
Final Drill Date: 1981-02-08
Well Total Depth: 5385.00 ft
Configuration: Vertical
Latitude: 40.730000
Longitude: -81.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-10-16 198 VIKING RESOURCES CORP GeoDate 10/16/80
Original Spud 1981-02-03
Completed 1981-02-08
Reached Total Depth 1981-02-08
CO 1992-09-24 3766 PDL SERVICES INC GeoDate 10/16/80
CO 1994-11-16 3766 PDL SERVICES INC GeoDate 11/16/94
Unknown 1994-11-16 Issued Date 11/16/94 Expired Date 11/16/95 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Construction Permit Expires 1995-11-16
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5193 5240 7
5193 5240 7
5193 5240 7

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 6000 Bbl 50000 VERSA-GEL

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 VIKING RESOURCES LLC 4264.00 601.00 0
1985 VIKING RESOURCES LLC 5067.00 995.00 305
1986 VIKING RESOURCES LLC 4433.00 881.00 364
1987 VIKING RESOURCES LLC 2943.00 700.00 333
1988 VIKING RESOURCES LLC 1260.00 332.00 365
1989 VIKING RESOURCES LLC 6290.00 682.00 235
1990 VIKING RESOURCES LLC 3027.00 235.00 365
1992 VIKING RESOURCES LLC 1189.00 137.00 304
1998 VIKING RESOURCES LLC 797.00 95.00 365
2008 PDL SERVICES INC 0.00 5.00 365
2009 PDL SERVICES INC 0.00 9.00 365
2010 PDL SERVICES INC 0.00 14.00 365
2011 PDL SERVICES INC 0.00 0.00 0
2012 PDL SERVICES INC 0.00 0.00 0
2013 PDL SERVICES INC 0.00 0.00 0
2014 PDL SERVICES INC 0.00 0.00 0
2015 PDL SERVICES INC 0.00 0.00 0
2016 PDL SERVICES INC 0.00 0.00 0
2017 PDL SERVICES INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 VIKING RESOURCES LLC Brine 0 0
1985 VIKING RESOURCES LLC Brine 240 305
1986 VIKING RESOURCES LLC Brine 160 364
1987 VIKING RESOURCES LLC Brine 120 333
1988 VIKING RESOURCES LLC Brine 100 365
1989 VIKING RESOURCES LLC Brine 441 235
1990 VIKING RESOURCES LLC Brine 378 365
1992 VIKING RESOURCES LLC Brine 80 304
1998 VIKING RESOURCES LLC Brine 20 365
2008 PDL SERVICES INC Brine 21 365
2009 PDL SERVICES INC Brine 27 365
2010 PDL SERVICES INC Brine 30 365
2011 PDL SERVICES INC Brine 0 0
2012 PDL SERVICES INC Brine 0 0
2013 PDL SERVICES INC Brine 0 0
2014 PDL SERVICES INC Brine 0 0
2015 PDL SERVICES INC Brine 0 0
2016 PDL SERVICES INC Brine 0 0
2017 PDL SERVICES INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1904892210 2011-8-26 0:00: PW No Violations
-2034395305 2019-7-11 0:00: PW No Violations 0.70
-374494181 2019-3-19 0:00: PW No Violations 0.50
-698068094 2009-11-3 0:00: PW No Violations
-902217495 2009-7-22 0:00: PW No Violations
0018952059 2010-03-15 Production Wells No Violations I received another complaint call from James Miller (330-868-3104) regarding pollution and contamination at this well. Nothing has been cleaned up at this site. I called Jay Cheslock about the unresolved N.O.V. I also called Kurt Kollar (OEPA) and Bart Ray (OEPA) regarding the wetland issue with this complaint. I will meet with Bart Ray at the site.
0079322655 2018-05-01 Production Wells No Violations I did a compliance notice follow-up inspection for this well. The well is not plugged nor is it legibly identified. The well is equipped with a pumpjack and the polish rod is tarnished. The tank battery consists of a steel production tank, a vertical separator and a meter. The wells production record show the well has not produced since 2010. The 2017 annual production report was not on file at the time of the inspection.
0374494181 2019-03-19 Production Wells No Violations My inspection found the well is not plugged or legibly identified as required by compliance notice issued on 8/25/2016. The well is equipped with a pumpjack and the production valves are open. The tank battery consists of a steel production tank, a vertical separator and a meter with a crumpled-up chart. The annual production report is submitted for 2017 and shows zero production. I called PDL at 330-868-7766 and requested to speak with Mr. Denver Belknap (Owner). The secretary advised me he was out. I gave her my contact information and requested a return call from Mr. Belknap.
0698068094 2009-11-03 Production Wells No Violations Nothing has been cleaned up at this site. I suggest turning this site over to the OEPA.
0757288164 2016-03-18 Production Wells No Violations I was on site to conduct an compliance notice follow-up inspection of this well. The stained straw around the wellhead has been removed and cleaned up and the belts have been installed on the pumpjack motor. The ID still has not been posted at the wellsite.
0842216130 2010-03-17 Production Wells No Violations The site has been cleaned up. The N.O.V. has been RESOLVED. I wrote the I.D. information on the side of the stock tank until an official I.D. is posted.
0902217495 2009-07-22 Production Wells No Violations Nothing has been done to clean up the site since my last inspection. I went to Denver Belknaps office to me with him regarding his outstanding N.O.V.s.
1095811361 2017-10-25 Production Wells No Violations I did a compliance notice follow-up inspection for this well. The well is not plugged nor is it legibly identified. The well is equipped with a pumpjack and the polish rod is tarnished. The tank battery consists of a steel production tank, a vertical separator and a meter. The paper chart appears to have not been changed since the last compliance inspection - the ink is saturated and blotted on the chart. Vegetation around the tank battery has been removed. No annual reports have been submitted since 2014. I contacted PDL Services Inc. on 10-25-2017 via e-mail (krisrhiel@frontier.com) which was the email address given to me by Denver Belknap (PDL Owner).
1244576150 2009-06-09 Production Wells Violations Noted The Uniontown office received a complaint call on 6-5-2009 from James Miller (330-868-3104) regarding pollution and contamination at this well. I inspected the site and found miscellaneous debris (wooden sills, plastic buckets, gloves, water truck hoses), a broken 1550 gallon plastic tank, oil stained soil around the wellhead, and what appeared to be a kill area in an adjacent wetland area located east of the pumping unit. I met with Denver Belknap, informed him of the violations and requested the clean up of the site. A new I.D. sign also needs to be posted on the stock tank.
1472147807 2016-08-24 Production Wells Violations Noted I conducted a compliance follow-up inspection on this well. The compliance notice was written by Inspector Dave Claus on 08-26-2011 for the following infractions:

1 - Well operations causing pollution and contamination - The operator failed to clean-up contaminated straw from around the wellhead 2 - Failure to legibly idenitfiy the well Inspector Shannon Mullins did a follow-up inspection on 03-18-2016 which she noted the straw had been cleaned up but the well was still not legibly identified.

The well is still not legibly identified. The well has a pumpjack with an electric motor and the polish rod has corrosion on it. The tubing head has no annulus plugs or valves and is open to the atmosphere. The RBDMS record shows this well last production was in 2010 for 14 barrels of oil and 30 barrels of brine. Also, the operator has failed to submit production reports for years 2013, 2014 and 2015. The tank battery consists of one 210 barrel tank, a vertical separator, and a meter which has no chart in it. There is no dike around the tank battery and it is overgrown with vegetation. This well presently is incapable of production. Consequently, this well shall be plugged in accordance with Ohio Revised Code section 1509.12(B). The well owner/operator shall submit a written plugging schedule to Shawn Murphy at 3575 Forest Lake Dr., Ste. 150, Uniontown, Ohio 44685 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.

1508940192 2017-07-07 Production Wells No Violations I did a compliance notice follow-up inspection for this well. The well is not plugged nor is it legibly identified. The well is equipped with a pumpjack and the polish rod is tarnished. The tank battery consists of a steel production tank, a vertical separator and a meter. Vegetation around the tank battery has been removed. No annual reports have been submitted since 2014. I met with landowner Jamie Miller while during the inspection.
1525192393 2018-01-11 Production Wells No Violations With Steve Ochs (District Supervisor), I did a compliance notice follow-up inspection for this well. The well is not plugged nor is it legibly identified. The well is equipped with a pumpjack and the polish rod is tarnished. The tank battery consists of a steel production tank, a vertical separator and a meter. The ink is saturated and blotted on the chart in the meter box.
1534257255 2018-08-14 Production Wells No Violations I did a compliance notice follow-up inspection for this well. The well is not plugged nor is it legibly identified. The well is equipped with a pumpjack. The well is not shut in. The Annual Production Reports from 2011 through 2016 show zero production reported. The annual production report for 2017 is not in the wells record. The tank battery consists of a steel production tank, a vertical separator and a meter. I left a message for Denver Belknap Jr. requesting a return call and advising that further enforcement action may be taken at any time.
1553004226 2018-12-20 Production Wells No Violations My inspection found the well is not plugged or legibly identified as required by compliance notice issued on 8/25/2016. The well is equipped with a pumpjack and the production valves are open. The tank battery consists of a steel production tank, a vertical separator and a meter with a crumpled-up chart. The well has zero production reported since 2011 . There is Annual Production report for 2017 which shows zero production.
1571854203 2019-10-21 0:00 PW No Violations 2.00
1577723160 2019-12-5 0:00: PW No Violations 0.60
1578683231 2020-1-10 0:00: PW No Violations 0.50
1859669957 2010-02-08 Production Wells No Violations I received another complaint call from James Miller (330-868-3104) regarding pollution and contamination at this well. Nothing has been cleaned up at this site. I called Jay Cheslock about the unresolved N.O.V.
18952059 2010-3-15 0:00: PW No Violations
1904892210 2011-08-26 Production Wells Violations Noted There are no belts on the pumping unit electric motor. There is still no I.D. sign posted at the tank battery. Stained straw around the wellhead needs removed.
1918190672 2018-09-07 Production Wells No Violations With Tom Hill (Regional Supervisor, Oil & Gas), My inspection found the well is not plugged or legibly identified as required by compliance notice issued on 8/25/2016. The well is equipped with a pumpjack and the production valves are open. The tank battery consists of a steel production tank, a vertical separator and a meter with a crumpled-up chart. The well has zero production reported since 2011 and no annual production report for 2017 is not reflected in the wells record at this time.
231938484 2020-1-10 0:00: PW No Violations 0.50
269611013 2019-11-25 0:00 PW No Violations 0.70
757288164 2016-3-18 0:00: PW No Violations
79322655 2018-5-1 0:00:0 PW No Violations 0.50
842216130 2010-3-17 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1244576150 US-OH-106524 2009-06-09 Well operation causing pollution and contamination
1244576150 US-OH-106525 2009-06-09 Failure to legibly identify well
1472147807 US-OH-113568 2017-01-11 Well shall be plugged
1472147807 US-OH-113569 2017-01-11 Dike or pit not able to prevent escape of brine or other wastes
1904892210 US-OH-119153 2011-09-06 Well operation causing pollution and contamination
1904892210 US-OH-119154 2011-09-06 Failure to legibly identify well

For data sources see[9]

References