If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-151-24060 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.84,"lon":-81.58,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Lawrence Township | |
Operator Name: SEAGULL DEVELOPMENT CORP | |
Well Pad ID: | |
Farm/Lease Name: MARTIN-ROHR UNIT | |
License Status: Producing | |
License Date: 1984-08-21 | |
Spud Date: 1984-10-08 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1984-11-12 | |
Well Total Depth: 4227.00 ft | |
Configuration: Vertical | |
Latitude: 40.840000 | |
Longitude: -81.580000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1984-08-21 | Issued Date 8/21/84 Expired Date 2/17/85 Acres 0160000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04227 Proposed Drill Depth 04227 |
Original Spud | 1984-10-08 | CHG ACRE 12-30-84 |
Completed | 1984-11-12 | CHG ACRE 12-30-84 |
Reached Total Depth | 1984-11-12 | CHG ACRE 12-30-84 |
CO | 1984-12-29 | 139 MB OPERATING CO INC GeoDate 8/21/84 |
Completion Report Received | 1985-01-23 | CHG ACRE 12-30-84 |
Construction Permit Expires | 1985-02-17 | CHG ACRE 12-30-84 |
Change of Owner | 2000-06-30 | Operator changed from 139, MB OPERATING CO INC to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2005-12-27 | Operator changed from 6674, GREAT LAKES ENERGY PTNSHP LLC to 1304, SEAGULL DEVELOPMENT CORP |
Record Last Modified | 2017-02-15 | CHG ACRE 12-30-84 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4035 | 4104 | 19 |
4035 | 4104 | 19 | |
4035 | 4104 | 19 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 4263 Bbl | 0 | FRAC: H2O |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | MB OPERATING CO INC | 13977.00 | 168.00 | 342 |
1986 | MB OPERATING CO INC | 18648.00 | 89.00 | 365 |
1987 | MB OPERATING CO INC | 18556.00 | 0.00 | 365 |
1988 | MB OPERATING CO INC | 13755.00 | 73.00 | 366 |
1989 | MB OPERATING CO INC | 11642.00 | 0.00 | 365 |
1990 | MB OPERATING CO INC | 6843.00 | 0.00 | 365 |
1991 | MB OPERATING CO INC | 3641.00 | 84.00 | 365 |
1992 | MB OPERATING CO INC | 2270.00 | 0.00 | 366 |
1993 | MB OPERATING CO INC | 1145.00 | 0.00 | 365 |
1994 | MB OPERATING CO INC | 601.00 | 0.00 | 365 |
1995 | MB OPERATING CO INC | 562.00 | 0.00 | 365 |
1996 | MB OPERATING CO INC | 1601.00 | 0.00 | 366 |
1997 | MB OPERATING CO INC | 1172.00 | 0.00 | 365 |
1998 | MB OPERATING CO INC | 1561.00 | 0.00 | 365 |
1999 | MB OPERATING CO INC | 85.00 | 46.00 | 273 |
2000 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2001 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2002 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2003 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2004 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2005 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2006 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2007 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2008 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2009 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2010 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2011 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2012 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 365 |
2013 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 0 |
2014 | SEAGULL DEVELOPMENT CORP | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1226536488 | 2018-12-7 0:00: | PW | No Violations | 0.50 |
-606993852 | 2019-3-25 0:00: | PW | No Violations | |
-785822350 | 2017-2-10 0:00: | PW | No Violations | 1.00 |
0000PL5308 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0571684050 | 2018-09-14 | Production Wells | No Violations | My inspection for Chiefs Order 2018-211 for Plugging Required found the well has not been plugged and abandoned as required by the Chiefs Order issued on 07-27-2018. The order required the plugging, abandoning and site restoration of this well within 30 days after receipt of the order by Seagull Development Corp. A review of the wells record shows no issued Plug and Abandon permit for this well at this time. |
0606993852 | 2019-03-25 | Production Wells | No Violations | My inspection for Chiefs Order 2018-211 Plugging Required issued on 07-27-18 found the well is not plugged. A review of the wells record shows the no Plug and Abandon permit being issued at this time. |
0654912119 | 2017-07-11 | Production Wells | No Violations | I conducted a compliance notice follow-- |
0785822350 | 2017-02-10 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection on this well. The well is not plugged. The well is topped with a swage on the 4.5 casing. The well is shut-in. The flowline valve is closed. The line going to the domestic gas meter is open and there is a closed valve on the domestic line after the meter. The well is identified at the tank but the sign is faded. It has the incorrect owner listed and no current emergency contact number. The tank battery consist of a 210 barrel tank, an inground concrete brine tank, a vertical separator. There is no dike and the tank battery is overgrown with vegetation. |
0894001768 | 2018-03-07 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection on this well. This well is not plugged. The well was observed from outside the fence do to cattle grazing in the field. The 4.5 casing has a swage and there is a domestic gas line. The tank battery has no dike. The tank battery consists of a steel production tank, an inground concrete brine vault, a vertical separator and a meter box. The tank battery is over-grown with vegetation and is located upslope within ~ 100 ft. west of a pond. The well site is now located in fenced pasture land. |
1226536488 | 2018-12-07 | Production Wells | No Violations | My inspection found the well is not plugged and abandoned as required by Chiefs Order 2018-211 Plugging Required. The Chiefs Order required the plugging and abandonment of the well with the restoration of the well and tank battery site within 30 days after receipt of the order. The Chiefs Order was issued 7-27-18. A review of the wells record shows the no Plug and Abandon permit being issued at this time. |
1346396110 | 2016-02-03 | Production Wells | Violations Noted | I conducted an compliance notice follow-up inspection on this well. The wellhead is a 4.5 inch casing with a swage into a 2 inch line and has had the rods and tubing removed. The valves are closed on the wellhead. There was also a domestic line with a meter connected to the 4.5 inch casing and was also shut in. There is no signage at the wellhead. The tank battery is heavily overgrown with brush and small trees and contains a 210 BBL production tank, mechanical separator, concrete brine tank and chart box. The flow line has been disconnected from the production tank and connection lines from the mechanical separator have also been disconnected from the other production equipment. There is signage at the tank battery. The tank battery is not diked, and a pond is 75 feet downhill from the tank battery. The lease access is stable and driveable. The state database records show that the well has not been in production since 1999. This well is incapable of production and shall be plugged per Ohio Revised Code 1509.12(B) within 180 days. |
1468501395 | 2016-07-12 | Production Wells | No Violations | A compliance notice follow-up inspection was done on 07-12-2016. The initial Compliance Notice was issued on 05-26-2015 for the following non-compliance issues which to date have not been remedied by the operator:
Ohio Administrative Code (OAC): 1501: 9-9- 1501: 9-9-
With that, the inspection found the tank battery still has no dike, the well is not legibly identified and the well is not plugged. Also, RBDMS record shows no plugging permit being issued to date. |
1491581824 | 2017-04-07 | Production Wells | No Violations | I conducted a compliance notice follow-- |
1510923472 | 2017-11-14 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection on this well. This well is not plugged. The well is shut in. The wellhead is equipped with a 4.5 inch casing with a closed valve. A swage is attched to the valve which reduces to 2 inch line which is plugged. The production flowline valve is closed. The domestic line valve is open and is connected to a meter which has valve on the outflow which is closed. The tank battery has no dike. The tank battery consists of a steel production tank, an inground concrete brine vault, a vertical separator and a meter box. The tank battery is over-grown with vegetation and is located upslope within ~ 100 ft. west of a pond. The well site is now located in fenced pasture land. I called 330-854-4339 on 11-17-2017 twice the phone had a busy signal. |
1527706471 | 2018-05-30 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection on this well. This well is not plugged. The wells 4.5 casing has a swage and there is a domestic gas line. The tank battery consists of a steel production tank, an inground concrete brine vault, a vertical separator and a meter box. The tank battery is over-grown with vegetation and is located upslope within ~ 100 ft. west of a pond. The well site is now located in fenced pasture land. There are cattle pasturing were the well is located, |
1530630678 | 2018-07-03 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection on this well. This well is not plugged. The wells 4.5 casing has a swage and there is a domestic gas line. The domestic gas line valve off the meter is partially opened. I spoke with the landowner, he advised me he was not receiving any gas from the well. He believes the pasturing cattle may have opened the valve. The tank battery consists of a steel production tank, an inground concrete brine vault, a vertical separator and a meter box. The tank battery is over-grown with vegetation and is located upslope within ~ 100 ft. west of a pond. |
1771974081 | 2015-05-19 | Production Wells | Violations Noted | I was on location to perform an inspection of this production well. The lease road is a shared driveway that turns into a grass field. The tank battery is heavily overgrown and contains a 210bbl production tank, a disconnected vertical separator, concrete brine tank and chart box. The tank battery does not contain identification or a dike, and a pond is 75 downhill from the tank battery. The wellhead has had the rods and tubing taken out of the well. Currently the well is 4.5 diameter casing swaged to 2. The flowline coming from the 4.5 diameter casing is shut in. A house gas connection is on the 4.5 diameter casing but is also shut in after the house gas meter. I talked with the current owner of the residence that once received gas from this well and they are now on propane and are not receiving gas. This well has not shown production since 1999 when it was owned by M B Operating. This well is incapable of production and shall be plugged per Ohio Revised Code 1509.12(B) within 180 days. |
571684050 | 2018-9-14 0:00: | PW | No Violations | 1.00 |
654912119 | 2017-7-11 0:00: | PW | No Violations | 0.70 |
894001768 | 2018-3-7 0:00:0 | PW | No Violations | 0.70 |
PL5308 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1346396110 | US-OH-110040 | 2016-07-26 | 9-9-05(A)10 | Failure to legibly identify well |
1346396110 | US-OH-110041 | 2016-07-26 | 9-9-05(A)9 | No SPCC dike/or failure to keep dike free of water or oil |
1346396110 | US-OH-110042 | 2016-07-26 | NONE | Well shall be plugged |
1771974081 | US-OH-117643 | 2015-06-09 | Failure to legibly identify well | |
1771974081 | US-OH-117644 | 2015-06-09 | No SPCC dike/or failure to keep dike free of water or oil | |
1771974081 | US-OH-117645 | 2015-06-09 | Well shall be plugged |
For data sources see[9]