34-151-24988

Well Details

Well ID: 34-151-24988
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Nimishillen Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: FLINTKOTE (ERP #1)
License Status: Active Injection
License Date: 2011-07-25
Spud Date: 1996-06-07
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1996-06-11
Well Total Depth: 4925.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -81.280000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1996-05-08 Issued Date 5/8/96 Expired Date 5/8/97 Acres 0706720 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04925 Proposed Drill Depth 04925
Original Spud 1996-06-07 CONVERTED TO EOR INJECTION
Completed 1996-06-11 CONVERTED TO EOR INJECTION
Reached Total Depth 1996-06-11 CONVERTED TO EOR INJECTION
CO 1996-07-30 139 MB OPERATING CO INC GeoDate 5/8/96
Completion Report Received 1996-09-05 CONVERTED TO EOR INJECTION
Change of Owner 2000-06-30 Operator changed from 139, MB OPERATING CO INC to 6674, GREAT LAKES ENERGY PTNSHP LLC
Change of Owner 2010-04-08 Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC
APP 2011-07-25 Proposed Formations:CLINTON, Issued Date:7/25/2011, Expired Date:7/24/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:EOR, Proposed Well Class:ERP
Last Compliance Report 2011-07-27 CONVERTED TO EOR INJECTION
Construction Permit Expires 2013-07-24 CONVERTED TO EOR INJECTION
Record Last Modified 2017-02-15 CONVERTED TO EOR INJECTION

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4697 4808 0
4697 4808 0
2006-09-11 4700 4806 40
4700 4806 40
4697 4808 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 196395 Gal 0 FRAC W/196,395 GAL SLICKWATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1996 MB OPERATING CO INC 2729.00 3204.00 366
1997 MB OPERATING CO INC 6853.00 5785.00 365
1998 MB OPERATING CO INC 4397.00 3517.00 365
1999 MB OPERATING CO INC 2649.00 1814.00 273
2000 RANGE RESOURCES-APPALACHIA LLC 2801.00 1885.00 365
2001 RANGE RESOURCES-APPALACHIA LLC 2763.00 1536.00 365
2002 RANGE RESOURCES-APPALACHIA LLC 2719.00 1340.00 365
2003 RANGE RESOURCES-APPALACHIA LLC 2242.00 1173.00 365
2004 RANGE RESOURCES-APPALACHIA LLC 2144.00 1035.00 365
2005 RANGE RESOURCES-APPALACHIA LLC 1794.00 833.00 365
2006 RANGE RESOURCES-APPALACHIA LLC 1717.00 783.00 365
2007 RANGE RESOURCES-APPALACHIA LLC 1515.00 711.00 365
2008 RANGE RESOURCES-APPALACHIA LLC 1413.00 559.00 365
2009 RANGE RESOURCES-APPALACHIA LLC 1150.00 522.00 365
2010 ENERVEST OPERATING LLC 1086.00 342.00 365
2011 ENERVEST OPERATING LLC 996.00 476.00 0
2013 ENERVEST OPERATING LLC 26.00 0.00 31
2014 ENERVEST OPERATING LLC 0.00 0.00 0
2015 ENERVEST OPERATING LLC 0.00 0.00 31
2016 ENERVEST OPERATING LLC 0.00 0.00 55
2017 ENERVEST OPERATING LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1996 MB OPERATING CO INC Brine 296 366
1997 MB OPERATING CO INC Brine 1574 365
1998 MB OPERATING CO INC Brine 872 365
1999 RANGE RESOURCES-APPALACHIA LLC Brine 154 92
2000 RANGE RESOURCES-APPALACHIA LLC Brine 721 365
2001 RANGE RESOURCES-APPALACHIA LLC Brine 490 365
2002 RANGE RESOURCES-APPALACHIA LLC Brine 518 365
2003 RANGE RESOURCES-APPALACHIA LLC Brine 426 365
2004 RANGE RESOURCES-APPALACHIA LLC Brine 56 365
2005 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2006 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2007 RANGE RESOURCES-APPALACHIA LLC Brine 70 365
2008 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2009 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 0 365
2011 ENERVEST OPERATING LLC Brine 69
2013 ENERVEST OPERATING LLC Brine 0 31
2014 ENERVEST OPERATING LLC Brine 0 0
2015 ENERVEST OPERATING LLC Brine 0 31
2016 ENERVEST OPERATING LLC Brine 0 55
2017 ENERVEST OPERATING LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1184323342 2016-7-15 0:00: ER No Violations
-1204930873 2014-3-6 0:00:0 ER No Violations
-1232128945 2016-3-31 0:00: ER No Violations
-1251167757 2020-4-8 0:00:0 SW No Violations 0.30
-1446515771 2017-4-21 0:00: ER No Violations
-1531285206 2014-5-30 0:00: ER No Violations
-1587259355 2016-11-4 0:00: ER No Violations
-162796799 2014-9-16 0:00: ER No Violations
-1835456530 2015-5-29 0:00: ER No Violations
-185827094 2014-7-24 0:00: ER No Violations
-1911380653 2015-9-14 0:00: ER No Violations
-1984803445 2018-10-24 0:00 SW No Violations 0.30
-2030705396 2014-12-12 0:00 ER No Violations
-2036196560 2013-12-27 0:00 ER No Violations
-258206877 2012-6-11 0:00: ER No Violations
-540088601 2017-12-15 0:00 SW No Violations 0.30
-549858604 2012-3-30 0:00: ER No Violations
-682109595 2020-6-17 0:00: ER No Violations 0.30
-861536326 2018-5-9 0:00:0 SW No Violations 1.00
-877793010 2019-2-14 0:00: ER No Violations 0.40
0000005811 Preliminary Restoration No Violations PASSED Y WITNESSED 10/1/96 INSPECTOR BRETT FARNSWORTH DATE 10/0119/96 DATA FROM OLD VAX INFO
0062618667 2011-06-29 Enhanced Recovery Project No Violations This well was inspected as part of a Enhanced Recovery Project. This well will be used as an injection site. Once the production wells pumping unit is removed and the well is converted into an injection well, place a containment dike around the well head and fence off the site. Excavate, remove and properly dispose of the stained soil (25 long x 5 wide area) from around the wellhead.
0162796799 2014-09-16 Enhanced Recovery Project No Violations An inspection of the well and injection facility found no violations.
0185827094 2014-07-24 Enhanced Recovery Project No Violations There were no violations found at the time of inspection.
0248932592 2015-03-16 Enhanced Recovery Project No Violations There were no violations found at the time of inspection.
0258206877 2012-06-11 Enhanced Recovery Project No Violations My inspection of this well site found no violations at the time.
0540088601 2017-12-15 Salt Water Injection Well No Violations I found the injection and facility in good repair on the day of my inspection. I observed no leaks or spills. An identification sign is posted at the facility and well. The facility and well are secure with a locked chain link fence. There are no violations at this time.
0549858604 2012-03-30 Enhanced Recovery Project No Violations I witnessed the testing of the flowline to 1410 PSI for 27 minutes. There was no loss in pressure - test passed.
0627470311 2014-04-21 Enhanced Recovery Project No Violations There were no violations found at the time of inspection.
0861536326 2018-05-09 Salt Water Injection Well No Violations I found the injection well not operating on the day of my inspection. I observed no leaks or spills. The proper identification is posted. The chain link fence is locked at the well and facility. There are no violations at this time.
0877793010 2019-02-14 Enhanced Recovery Project No Violations I found the injection well shut-in with a closed gate valve on the injection tubing. The fencing around the injection well is locked. Identification signs are posted. I observed no leaks or spills.
0963778483 2017-08-24 Salt Water Injection Well No Violations I performed a UIC inspection on the above location. Unloading pad and tank battery area is clear of debris. ID signs were posted. No noted violations were noted at this time.
1010754058 2017-03-29 Enhanced Recovery Project No Violations Previously, the well operation was suspended. The injection line to the well was shut-in. No attempt has been made to repair the well. There were no additional issues found.
1059004717 2012-11-26 Enhanced Recovery Project No Violations I inspected the Flintkote (ERP #1) No. 38 (34151249880000) injection well on November 26, 2012; I was accompanied by Steve Ochs. There were no violations at the wellhead or at the brine tanks.
1119556333 2012-11-26 Enhanced Recovery Project No Violations My inspection of the surface facility and injection well was accompanied by Ryan Channell. There were no violations found at the time of inspection.
1132338900 2015-12-22 Enhanced Recovery Project No Violations An inspection of the injection well and surface facility found no violations.
1155860357 2019-6-17 0:00: ER No Violations 0.50
1184323342 2016-07-15 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1204930873 2014-03-06 Enhanced Recovery Project No Violations There were no violations found at the time of inspection.
1232128945 2016-03-31 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1326079320 2012-01-06 Salt Water Injection Well No Violations Rick Kepler (Enervest) called me for a Mechanical Integrity Test (MIT). When I arrived at the site, a new Halliburton PLT packer was run by Bishop Well Service on 2.375 EUE tubing and set at 4662 (38 above the top perforation) with 15,000 pounds of compression. B&E Well Services pumped and circulated 50 barrels of packer inhibitor in the annulus. The annulus was pressured up to 1100 PSI. The test was started at 1100 PSI and ended at 1100 PSI after 17 minutes. The MIT PASSED. Rick Kepler will submit a tubing tally to Tom Tomastik at the Columbus office. The allowable injection pressure for this well is 1080 PSI.
143124803 2020-1-27 0:00: ER No Violations 0.30
1446442473 2017-11-01 Enhanced Recovery Project No Violations I found the UIC facility in good repair on the day of my inspection. There is an identification posted at the facility. There are identification signs posted at the well. There is a locked chain link fences around the well and facility. I observed no leaks or spills. There are no violations at this time.
1446515771 2017-04-21 Enhanced Recovery Project No Violations The well has been shut down due to a mechanical integrity issue discovered earlier. The injection line was found shut-in. The casing pressure was not gauged. There were no additional violations.
1499254212 2013-07-15 Enhanced Recovery Project No Violations My inspection found no violations at the time.
1507670989 2018-02-26 Salt Water Injection Well No Violations I was on location to inspect the facility and injection well. I found the well not in operation on the day of my inspection. I observed no leaks or spills at the wellhead. An identification sign is posted next to the wellhead and at the facility. There are no violations at this time.
1531285206 2014-05-30 Enhanced Recovery Project No Violations An inspection of the well and injection facility found no violations.
1535732876 2018-08-31 Salt Water Injection Well No Violations I found the injection well shut-in with a closed gate valve on the tubing. There is a locked chain link fence around the well. There is an identification sign posted. I observed no leaks or spills.
1587259355 2016-11-04 Enhanced Recovery Project Violations Noted A mini test was performed on the well. Numerous attempts to pressurize the tubing/casing annulus failed. The company representative (Mike Burkhart) was instructed to suspend the injection operation.
1632094132 2019-5-2 0:00:0 ER No Violations 0.30
1736625602 2019-12-10 0:00 ER No Violations 0.40
1835456530 2015-05-29 Enhanced Recovery Project No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
1837636448 2017-06-22 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. The well has been shut down since failing a pressure test. The injection line was shut-in. There were no additional violations.
1911380653 2015-09-14 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1972248100 2019-8-9 0:00:0 ER No Violations 0.50
1984803445 2018-10-24 Salt Water Injection Well No Violations I found the injection well shut--in and waiting for repairs. Identification signs are posted.
2030705396 2014-12-12 Enhanced Recovery Project No Violations The injection well and surface facility were inspected. There were no violations found at the time.
2036196560 2013-12-27 Enhanced Recovery Project No Violations There were no violations at the time of inspection.
248932592 2015-3-16 0:00: ER No Violations
5811 PL No Violations
62618667 2011-6-29 0:00: ER No Violations
627470311 2014-4-21 0:00: ER No Violations
911370458 2020-8-14 0:00: SW No Violations 0.40
963778483 2017-8-24 0:00: SW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1587259355 US-OH-115527 2017-04-21 9-5-10(H) Mechanical failure/contamination

For data sources see[9]