X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-151-25099

Well Details

Well ID: 34-151-25099
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Paris Township
Operator Name: PDL SERVICES INC
Well Pad ID:
Farm/Lease Name: BELKNAP
License Status: Producing
License Date: 1998-06-08
Spud Date: 1998-06-08
Spud Drilling Contractor: ROSE RUN DRILLING
Final Drill Date: 1998-06-16
Well Total Depth: 6430.00 ft
Configuration: Vertical
Latitude: 40.730000
Longitude: -81.120000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1998-06-08 Proposed Formations:ROSE RUN, Issued Date:6/8/98, Expired Date:6/8/99 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EOUT
Original Spud 1998-06-08 RBDMS Rec
Completed 1998-06-16 RBDMS Rec
Reached Total Depth 1998-06-16 RBDMS Rec
Completion Report Received 1999-02-12 RBDMS Rec
Construction Permit Expires 1999-06-08 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-05-17 5200 5276 78
5200 5276 78
5200 5276 78

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 24000 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 PDL SERVICES INC 441.00 83.00 365
2012 PDL SERVICES INC 648.00 88.00 366
2013 PDL SERVICES INC 443.00 61.00 365
2014 PDL SERVICES INC 487.00 61.00 365
2015 PDL SERVICES INC 210.00 0.00 365
2016 PDL SERVICES INC 250.00 0.00 365
2017 PDL SERVICES INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 PDL SERVICES INC Brine 5 365
2012 PDL SERVICES INC Brine 7 366
2013 PDL SERVICES INC Brine 3 365
2014 PDL SERVICES INC Brine 8 365
2015 PDL SERVICES INC Brine 0 365
2016 PDL SERVICES INC Brine 0 365
2017 PDL SERVICES INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1167231072 2011-8-16 0:00: PW No Violations
-143974587 2017-10-24 0:00 PW No Violations 0.50
-43922732 2017-7-7 0:00:0 PW No Violations 0.50
-940612009 2009-5-6 0:00:0 PW No Violations
0043922732 2017-07-07 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is identified. The well is equipped with a pumpjack with an electric motor. The production and domestic gas lines are open. The well is producing and the pumpjack is operating. The tank battery consists of two 210 barrel tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25144, 25245, 25167, 25108 and 25247. No annual production reports have been submitted since 2014. Ergon Trucking (Truck # 1504) is on location picking up a load of oil from the production tanks.
0143974587 2017-10-24 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is identified. The well is equipped with a pumpjack with an electric motor. The production and domestic gas lines are open. The tank battery consists of two 210 barrel tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25144, 25245, 25167, 25108 and 25247. No annual production reports have been submitted since 2014. Since the well is in production, legibly identified and the contamination cleaned up, the outstanding compliances issues are passed.
0706259941 2015-12-30 Production Wells No Violations I was on location with District Supervisor Rick Anderson to preform an inspection of this well and check the status of the required actions. The well has been reworked and is now currently pumping. The old rods and tubing are on location and paraffin staining is visible at the location. The wellhead has non mobile staining on the wellhead. The compressor on location would need to be rebuilt to be able to sell gas into a Columbia gas line on the property for this well. The operator states they will be cleaning up the location and reworking the compressor for gas sales.
0753625635 2017-05-04 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is not plugged or legibly identified. The well is equipped with a pumpjack with an electric motor. The production and domestic gas lines are open. The tank battery consists of two 210 barrel tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25144, 25245, 25167, 25108 and 25247. No annual production reports have been submitted since 2014. I met with Denver Belknap (owner) and spoke with him about the issues with the well.
0778153322 2015-10-29 Production Wells No Violations I was on location to check the status of the required cleanup and maintenance for this well. The well has had proper identification posted at the wellhead as required. The belt guard has been reinstalled on the pumpjack. There has been no application to plug this well or an attempt to put the well into production.
0910960095 2015-09-18 Production Wells No Violations I was on location to check the status of the required cleanup and maintenance for this well due on 9/17/2015. The debris around the wellhead is still present and the wellhead has not been tightened as required. I have contacted Denny Belknap and left a voicemail explaining that the due date has passed and that the required work must be completed as soon as possible.
0940612009 2009-05-06 Production Wells No Violations I met with Denver (Denny) Belknap, Jr. on the location and discussed the well. The well has been put into production. However, there is still no I.D. sign at the wellhead or at the tank battery and there is still oil contaminated soil located around the wellhead. Denny said that he will resolve the violations.
0970904731 2007-11-07 Production Wells No Violations FOLLOW UP TO NOV # 1195149411 There is a pumping unit with an electric motor. The electric line has been disconnected. The well is idle. There is no I.D. sign and there is oil contaminated soil located around the wellhead. There is no record of reported production. Clean up all contaminated soil; post an I.D. sign; and produce the well or plug it.
1167231072 2011-08-16 Production Wells No Violations I met with Denver Belknap and Russ Lilly on-site. The well appears capable of production. Instructed to install I.D. sign at the wellhead and at the tank battery and clean up around the wellhead.
1195149411 2007-11-07 Production Wells Violations Noted There is a pumping unit with an electric motor. The electric line has been disconnected. The well is idle. There is no I.D. sign and there is oil contaminated soil located around the wellhead. There is no record of reported production. Clean up all contaminated soil; post an I.D. sign; and produce the well or plug it.
1449495701 2015-12-03 Work Over Reconditioning No Violations I was on location to check the status of the workover for this well to put it back into production. The Ditty service rig is pulling rods in the well and plans to grab onto the broken rod in the well. The rig will replace the rods and pump the well to determine if the down hole pump is still in working condition. If the pump is locked up and will not pump they will pull tubing and rods and have the downhole pump replaced.
1511836873 2016-03-18 Production Wells No Violations I conducted a compliance notice follow-up inspection of this well. The valves on the wellhead were open and a domestic line was also connected to the wellhead and open. Signage at the wellhead was legible. The tank battery consisted of four 210 BBL production tanks, one 100 BBL production tank, a heater treater separator, drip bottle and chart box with no chart. Two of the 210 BBL tanks were leaking brine from the tank valve plugs. There was signage at the tank battery and the dike and access to the site was good. I called Denver Belknap of PDL Services, Inc to discuss the issue of the leaking tanks. Denver stated that someone would be out to immediately access and remedy the issue. There have been no updates regarding production records in the state database since 2012.
2088479232 2015-09-11 Production Wells No Violations I was on location to check the status of bringing this well into compliance. The well has had proper identification posted at the wellhead as required. There is heavy machinery on location and continual work is being completed on the wells as required. A follow up inspection will be completed to ensure the wells are brought into compliance.
706259941 2015-12-30 0:00 PW No Violations 1.00
753625635 2017-5-4 0:00:0 PW No Violations 0.70
778153322 2015-10-29 0:00 PW No Violations 0.50
910960095 2015-9-18 0:00: PW No Violations 1.50
970904731 2007-11-7 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1195149411 US-OH-105135 2007-11-15 Well operation causing pollution and contamination
1195149411 US-OH-105136 2007-11-15 Failure to legibly identify well
1195149411 US-OH-105137 2007-11-15 Well shall be plugged

For data sources see[9]

References