Well Details

Well ID: 34-151-25144
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Paris Township
Operator Name: PDL SERVICES INC
Well Pad ID:
Farm/Lease Name: BELKNAP
License Status: Producing
License Date: 1999-07-06
Spud Date: 1999-08-13
Spud Drilling Contractor: GRIM DRILLING
Final Drill Date: 1999-10-05
Well Total Depth: 810.00 ft
Configuration: Vertical
Latitude: 40.730000
Longitude: -81.120000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-07-06 Proposed Formations:BEREA, Issued Date:7/6/99, Expired Date:7/5/2000 6:00:00 AM, Drilling unit acres:1.26, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1999-08-13 THIS WELL HAD THE SURFACE CASING PULLED SO THE PROD CASING BECAME THE SURFACE CASING WHICH SHOULD NOT HAVE BEEN ALLOWED TO HAVE BEEN PERF'D. 5/23/05 JG
Completed 1999-10-05 THIS WELL HAD THE SURFACE CASING PULLED SO THE PROD CASING BECAME THE SURFACE CASING WHICH SHOULD NOT HAVE BEEN ALLOWED TO HAVE BEEN PERF'D. 5/23/05 JG
Reached Total Depth 1999-10-05 THIS WELL HAD THE SURFACE CASING PULLED SO THE PROD CASING BECAME THE SURFACE CASING WHICH SHOULD NOT HAVE BEEN ALLOWED TO HAVE BEEN PERF'D. 5/23/05 JG
Construction Permit Expires 2000-07-05 THIS WELL HAD THE SURFACE CASING PULLED SO THE PROD CASING BECAME THE SURFACE CASING WHICH SHOULD NOT HAVE BEEN ALLOWED TO HAVE BEEN PERF'D. 5/23/05 JG
Completion Report Received 2000-11-03 THIS WELL HAD THE SURFACE CASING PULLED SO THE PROD CASING BECAME THE SURFACE CASING WHICH SHOULD NOT HAVE BEEN ALLOWED TO HAVE BEEN PERF'D. 5/23/05 JG
Record Last Modified 2017-02-15 THIS WELL HAD THE SURFACE CASING PULLED SO THE PROD CASING BECAME THE SURFACE CASING WHICH SHOULD NOT HAVE BEEN ALLOWED TO HAVE BEEN PERF'D. 5/23/05 JG

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-01-09 728 768 80
728 768 80
728 768 80

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 0 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 PDL SERVICES INC 0.00 0.00 0
2012 PDL SERVICES INC 0.00 0.00 0
2013 PDL SERVICES INC 0.00 0.00 0
2014 PDL SERVICES INC 0.00 0.00 0
2015 PDL SERVICES INC 0.00 50.00 365
2016 PDL SERVICES INC 0.00 90.00 365
2017 PDL SERVICES INC 0.00 40.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 PDL SERVICES INC Brine 0 0
2012 PDL SERVICES INC Brine 0 0
2013 PDL SERVICES INC Brine 0 0
2014 PDL SERVICES INC Brine 0 0
2015 PDL SERVICES INC Brine 0 365
2016 PDL SERVICES INC Brine 0 365
2017 PDL SERVICES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1068486563 2009-5-6 0:00:0 PW No Violations
-1097482003 2018-8-14 0:00: PW No Violations 0.50
-1215520722 2015-9-11 0:00: PW No Violations 0.50
-1317488733 2015-10-29 0:00 PW No Violations 0.50
-198410974 2017-7-7 0:00:0 PW No Violations 0.50
-2139284952 2017-5-4 0:00:0 PW No Violations 0.70
-424163551 2011-8-26 0:00: PW No Violations
-740225548 2015-12-30 0:00 PW No Violations 1.00
-82439718 2019-3-19 0:00: PW No Violations 0.50
0046041851 2017-10-24 Production Wells No Violations I conducted a Compliance Notice follow--25099, 25245, 25167, 25108 and 25247. No annual production reports have been submitted since 2014. I contacted PDL Services Inc. on 10-25-2017 via e-mail (krisrhiel@frontier.com) which was the email address given to me by Denver Belknap (PDL Owner).
0082439718 2019-03-19 Production Wells No Violations My inspection found the well is not plugged or legibly identified as requested by the Compliance Notice issued on 11-07-2007. The The well is equipped with a pumpjack with an electric motor and the production line is open. The 2017 Annual Production Report shows 50 barrels of oil were produced. The diked tank battery consists of two steel production tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. I called PDL at 330-868-7766 and requested to speak with Mr. Denver Belknap (Owner). The secretary advised me he was out. I gave her my contact information and requested a return call from Mr. Belknap.
0198410974 2017-07-07 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is not plugged or legibly identified. The well is equipped with a pumpjack with an electric motor and the production line is open. The stuffing box needs to be serviced. The diked tanks battery consists of two 210 barrel tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. No annual production reports have been submitted since 2014. Ergon Trucking (Truck # 1504) is on location picking up a load of oil from the production tanks.
0424163551 2011-08-26 Production Wells No Violations I met with Denver Belknap and Russ Lilly at the site. The well appears capable of production. There is still no I.D. sign posted at the wellhead or at the tank battery. Clean up necessary around the wellhead.
0432419511 2018-01-18 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is not plugged or legibly identified. The well is equipped with a pumpjack with an electric motor and the production line is open. The diked tanks battery consists of two steel production tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. The annual production reports for years 2015 and 2016 are reflected in the wells record. I contacted Denver Belknap Jr. (330-323-6976) and left a message.
0740225548 2015-12-30 Production Wells No Violations I was on location with District Supervisor Rick Anderson to perform an inspection of this well and check the status of required actions. The wellhead has non mobile staining on the wellhead. The operator has stated that this well may have the roads and tubing pulled from the well and sell gas from the casing. The compressor on location would need to be rebuilt to be able to sell gas into a Columbia gas line on the property. The operator states they will be cleaning up the location and reworking the compressor for gas sales.
0761466400 2018-05-21 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is not plugged or legibly identified. The well is equipped with a pumpjack with an electric motor and the production line is open. The diked tanks battery consists of two steel production tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. The annual production report for 2017 is not in the wells record at this time. I contacted Denver Belknap Jr. (330-323-6976) and left a message for a return call.
1068486563 2009-05-06 Production Wells No Violations I met with Denver (Denny) Belknap, Jr. on the location and discussed the well. The well has been put into production. However, there is still no I.D. sign at the wellhead or at the tank battery and there is still oil contaminated soil located around the wellhead. Denny said that he will resolve the violations.
1097482003 2018-08-14 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is not plugged or legibly identified as required by the compliance notice. The well is equipped with a pumpjack with an electric motor and the production line is open. The 2017 Annual Production Report is not recorded in the wells record. The diked tanks battery consists of two steel production tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. The well has reported production for 2015 and 2016. The annual production report for 2017 is not in the wells record currently. I left a message for Denver Belknap Jr. requesting a return call and advising that further enforcement action may be taken at any time.
1215520722 2015-09-11 Production Wells No Violations I was on location to check the status of bringing this well into compliance. The well has had proper identification posted at the wellhead as required. There is heavy machinery on location and continual work is being completed on the wells as required. A follow up inspection will be completed to ensure the wells are brought into compliance.
1262219741 2018-12-20 Production Wells No Violations My inspection found the well is not plugged or legibly identified as requested by the Compliance Notice issued on 11-07-2007. The The well is equipped with a pumpjack with an electric motor and the production line is open. The 2017 Annual Production Report shows 50 barrels of oil were produced. The diked tank battery consists of two steel production tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. The compliance notice was amended by adding a remedy required by date of 03-16-2019 and mailed certified to the owner. An electronic postal receipt shows the Compliance Notice was delivered and signed for on 09-21-2018.
1317488733 2015-10-29 Production Wells No Violations I was on location to check the status of the required cleanup and maintenance for this well. The well has had proper identification posted at the wellhead as required. The debris has been cleaned up around the wellhead. There has been no application to plug this well. I have not been contacted by the operator to prove that this well is capable of production.
1374481256 2007-11-07 Production Wells Violations Noted There is a pumping unit with an electric motor. The electric line has been disconnected. The well is idle. There is no I.D. sign and there is oil contaminated soil located around the wellhead. There is no record of reported production. Clean up all contaminated soil; post an I.D. sign; and produce the well or plug it.
1459173208 2016-03-18 Production Wells No Violations I conducted a compliance notice follow-up inspection of this well. The valves on the wellhead were open. The tank battery consisted of four 210 BBL production tanks, one 100 BBL production tank, a heater treater separator, drip bottle and chart box with no chart. Two of the 210 BBL tanks were leaking brine from the tank valve plugs. There was signage at the tank battery and the dike and access to the site was good. I called Denver Belknap of PDL Services, Inc to discuss the issue of the leaking tanks. Denver stated that someone would be out to immediately access and remedy the issue. There have been no updates regarding production records in the state database since 2012.
1536759091 2018-09-07 Production Wells No Violations On location with Tom Hill (Regional Supervisor - ODNR, Oil & Gas), The well is not plugged or legibly identified as requested by the Compliance Notice issued on 11-07-2007. The well is equipped with a pumpjack with an electric motor and the production line is open. The 2017 Annual Production Report is not recorded in the wells record. The diked tanks battery consists of two steel production tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. The well has reported production for 2015 and 2016. The annual production report for 2017 is not in the wells record currently. Since the well is producing the compliance notice can be passed once the well is legibly identified.

The following compliance issue needs to be completed:

  • Legibly identify the well - at the well, since it is a shared tank battery.
1787465118 2007-11-07 Production Wells No Violations FOLLOW UP TO NOV # 1374481256 There is a pumping unit with an electric motor. The electric line has been disconnected. The well is idle. There is no I.D. sign and there is oil contaminated soil located around the wellhead. There is no record of reported production. Clean up all contaminated soil; post an I.D. sign; and produce the well or plug it.
2139284952 2017-05-04 Production Wells No Violations I conducted a Compliance Notice follow-up inspection on this well. The well is not plugged or legibly identified. The well is equipped with a pumpjack with an electric motor and the production line is open. The stuffing box needs to be serviced. The diked tanks battery consists of two 210 barrel tanks, a vertical separator and a meter. The tank battery is shared with wells 151-25099, 25245, 25167, 25108 and 25247. No annual production reports have been submitted since 2014. I met with Denver Belknap (owner) and spoke with him about the issues with the well.
432419511 2018-1-18 0:00: PW No Violations 0.50
46041851 2017-10-24 0:00 PW No Violations 0.50
761466400 2018-5-21 0:00: PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1374481256 US-OH-111090 2007-11-15 Well operation causing pollution and contamination
1374481256 US-OH-111091 2007-11-15 Failure to legibly identify well
1374481256 US-OH-111092 2007-11-15 Well shall be plugged

For data sources see[9]