34-151-25472

Well Details

Well ID: 34-151-25472
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Pike Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: BAUM UNIT
License Status: Producing
License Date: 2005-12-23
Spud Date: 2006-02-08
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-02-13
Well Total Depth: 4916.00 ft
Configuration: Vertical
Latitude: 40.690000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-12-23 Proposed Formations:CLINTON, Issued Date:12/23/2005, Expired Date:12/23/2006 6:00:00 AM, Drilling unit acres:182.95, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2005-12-30 ADDED FOOTAGE: "765'NL & 905'EL OF NW QTR., SEC. 14".
Original Spud 2006-02-08 RBDMS Rec
Completed 2006-02-13 RBDMS Rec
Reached Total Depth 2006-02-13 RBDMS Rec
Completion Report Received 2006-03-23 RBDMS Rec
Construction Permit Expires 2006-12-23 RBDMS Rec
Change of Owner 2010-04-08 Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-06-13 4692 4795 39
4692 4795 39
4692 4795 39

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 3967 Bbl 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 RANGE RESOURCES-APPALACHIA LLC 4097.00 24.00 245
2007 RANGE RESOURCES-APPALACHIA LLC 3680.00 24.00 365
2008 RANGE RESOURCES-APPALACHIA LLC 2867.00 21.00 365
2009 RANGE RESOURCES-APPALACHIA LLC 2446.00 16.00 365
2010 ENERVEST OPERATING LLC 3385.00 0.00 365
2011 ENERVEST OPERATING LLC 2593.00 10.00 0
2012 ENERVEST OPERATING LLC 3057.00 21.00 366
2013 ENERVEST OPERATING LLC 2661.00 11.00 365
2014 ENERVEST OPERATING LLC 2358.00 23.00 365
2015 ENERVEST OPERATING LLC 1835.00 0.00 365
2016 ENERVEST OPERATING LLC 1895.00 21.00 366
2017 ENERVEST OPERATING LLC 2420.00 34.00 365
2018 ENERVEST OPERATING LLC 2134.00 37.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 RANGE RESOURCES-APPALACHIA LLC Brine 540 245
2007 RANGE RESOURCES-APPALACHIA LLC Brine 180 365
2008 RANGE RESOURCES-APPALACHIA LLC Brine 70 365
2009 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 0 365
2011 ENERVEST OPERATING LLC Brine 0
2012 ENERVEST OPERATING LLC Brine 0 366
2013 ENERVEST OPERATING LLC Brine 0 365
2014 ENERVEST OPERATING LLC Brine 40 365
2015 ENERVEST OPERATING LLC Brine 6 365
2016 ENERVEST OPERATING LLC Brine 16 366
2017 ENERVEST OPERATING LLC Brine 57 365
2018 ENERVEST OPERATING LLC Brine 47 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1238283432 2006-2-10 0:00: DD No Violations
-2007146025243466 2008-7-22 0:00: PW No Violations
-2007146025245411 2008-7-22 0:00: PL No Violations
1139260127 2006-02-06 Drill / Deepen / Reopen No Violations Locate access road and drilling location.
1177692639 2007-04-26 Production Wells Violations Noted I inspected the wellhead and tank battery for Preliminary Restoration. The I.D. sign at the pumping unit and the I. D. sign on the stock tank have the wrong permit number. The permit number listed is 34-151-2-5451, which is the Sisler #4 in Lawrence Township in Stark Co. The correct permit number is 34-151-2-5472. Correct the I.D. signs. Also, the separator for the Baum Unit # 3-A is located 36 from the Baum Unit # 2-A wellhead. Ohio Oil & Gas Rule 1501:9-9-05(A)(5) states that mechanical separators shall be set a minimum of 50 from the well. Move the separator to correct the safety violation and make sure that the stock tank is also a minimum of 50 from the wellhead. Call me at (330-284-5863) when these violations have been corrected.
1216836846 2008-07-22 Preliminary Restoration No Violations The location is reclaimed. The Preliminary Restoration is PASSED.
1238283432 2006-02-10 Drill / Deepen / Reopen No Violations Tripping back into the hole with drill pipe. Pits and liners are intact.
1267732694 2017-06-16 Production Wells No Violations I conducted a status check inspection on this well. The well is equipped with a pumpjack with an electric motor. The diked tank battery consists of a 210 barrel tank, a plastic brine tank, a vertical separator and a meter with a paper chart. The tank battery is shared with well # 151-25106. The well is legibly identified. There are no compliance issues noted at this time.
2007146025 2008-07-22 Production Wells No Violations The spacing violation and the I.D. sign violation have been RESOLVED.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1177692639 US-OH-104725 2007-04-30 Failure to legibly identify well
1177692639 US-OH-104726 2007-04-30 Violation of separator spacing requirements