Well Details

Well ID: 34-151-25763
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: ST JOHNS LUTHERAN UNIT
License Status: Final Restoration
License Date: 2016-09-06
Spud Date: 2012-02-13
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2012-02-20
Well Total Depth: 4585.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -81.500000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-09-29 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:9/29/2011, Expired Date:9/28/2013 12:00:00 PM, Drilling unit acres:69.43, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2012-01-13 CORRECTION TO FOOTAGE: SHOULD BE "595'NL & 165'EL OF SEC. 5".
Reached Total Depth 2012-02-20 SHOT PERFS@4152-53 (4) & 4318-20 (8) TO PERFORM REMEDIAL CEMENT SQUEEZE OVER AN AREA JUST ABOVE THE CLINTON SANDSTONE 3/5-3/9/12. UPDATED COORDINATES PER SURVEYOR-12/27/16 ALE.
Correction to Well 2012-06-01 UNIT SIZE INCREASED TO 72.53 ACRES.
Completion Report Received 2012-06-18 SHOT PERFS@4152-53 (4) & 4318-20 (8) TO PERFORM REMEDIAL CEMENT SQUEEZE OVER AN AREA JUST ABOVE THE CLINTON SANDSTONE 3/5-3/9/12. UPDATED COORDINATES PER SURVEYOR-12/27/16 ALE.
APP 2016-09-06 Proposed Formations:OHIO SHALE THRU CLINTON SANDSTONE, Issued Date:9/6/2016, Expired Date:9/6/2018 12:00:00 PM, Drilling unit acres:72.53, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-10-12 SHOT PERFS@4152-53 (4) & 4318-20 (8) TO PERFORM REMEDIAL CEMENT SQUEEZE OVER AN AREA JUST ABOVE THE CLINTON SANDSTONE 3/5-3/9/12. UPDATED COORDINATES PER SURVEYOR-12/27/16 ALE.
Record Last Modified 2018-04-28 SHOT PERFS@4152-53 (4) & 4318-20 (8) TO PERFORM REMEDIAL CEMENT SQUEEZE OVER AN AREA JUST ABOVE THE CLINTON SANDSTONE 3/5-3/9/12. UPDATED COORDINATES PER SURVEYOR-12/27/16 ALE.
Construction Permit Expires 2018-09-06 SHOT PERFS@4152-53 (4) & 4318-20 (8) TO PERFORM REMEDIAL CEMENT SQUEEZE OVER AN AREA JUST ABOVE THE CLINTON SANDSTONE 3/5-3/9/12. UPDATED COORDINATES PER SURVEYOR-12/27/16 ALE.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-07-13 4326 4331 10
2012-07-13 4354 4368 42
4326 4331 10
4354 4368 42
4386 4396 30
4326 4331 10
2012-07-13 4386 4396 30

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-03-20 H2O 15 94783 Gal 60000 Producers Service Corporation No fluid observed flowing from the annulus. No leaks or spills.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 OHIO VALLEY ENERGY SYSTEMS COR 0.00 188.00 184
2014 OHIO VALLEY ENERGY SYSTEMS COR 10814.00 169.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 681.00 42.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 0.00 15.00 60

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 184
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 11367 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 1789 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 263 60

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-565199799 2018-3-7 0:00:0 FR No Violations 0.70
0326271765 2016-10-04 Production Wells No Violations I conducted a status check inspection on this well. The well is to be plugged the week of 10-10-2016. The pumpjack has been removed. The rods and tubing are still in the well. The tank battery reclamation is almost complete. Don Nething (Ohio Valley Energy) will be the Field contact.
0565199799 2018-03-07 Final Restoration No Violations I did a Final Restoration inspection for this well. The site is graded with no active erosion and vegetated. A landowner waiver was received by the Uniontown Office of ODNR Oil & Gas on 11-03-2016 waiving the removal of the buried lines. The final restoration is passed.
0622374576 2015-09-16 Preliminary Restoration No Violations I was on location to check this well for preliminary restoration. The electrically driven pumpjack is currently shut in, contains a house gas connection and is fenced and landscaped. The well contains identification and has all required locks and valves. The tank battery is fenced and landscaped with identification. The tank battery contains a 140 bbl production tank, 100 bbl brine tank, a dike, mechanical separator and an identification sign. Vegetation on location has been established at this time. The identification signs posted on the wellhead and tank battery do not contain the address of the well and other required information. I have contacted the operator and new identification signs with the required information will be posted at the wellsite this week. I will perform a follow up inspection to ensure the proper identification is posted and will pass preliminary restoration at that time.
1476383650 2016-10-04 Production Wells No Violations I conducted a status check inspection on this well. The well is being prepared to be plugged and abandoned. The pumpjack has been removed as well as the tank battery. The rods and tubing are still in the well and a 100 barrel tank is still on location.
1480531084 2016-11-28 Final Restoration No Violations I conducted a final restoration inspection on this well. The original signature landowner waiver was received at the Uniontown office of Oil & Gas on 11-03-2016. The well and tank battery locations have been graded, seeded and mulched. There is no active erosion and the final restoration can be passed once vegetation has established.
1494602274 2017-05-12 Final Restoration No Violations I conducted a Final Restoration inspection on this well. The final restoration cannot be passed at this time. The well and tank battery site lack vegetation and both areas are ponding water. The area around the restoration is lawn which is being maintained as such. I left a message for Don Nething (Ohio Valley Energy) and advised him the final restoration cannot be passed at this time.
326271765 2016-10-4 0:00: PW No Violations 0.70
622374576 2015-9-16 0:00: PL No Violations 2.00

For data sources see[9]