Well ID: 34-153-20802 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.08,"lon":-81.62,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Summit | |
Municipality: Copley Township | |
Operator Name: D & D ENERGY COMPANY | |
Well Pad ID: | |
Farm/Lease Name: BOSS K | |
License Status: Producing | |
License Date: 1980-02-01 | |
Spud Date: 1980-09-22 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-09-26 | |
Well Total Depth: 3848.00 ft | |
Configuration: Vertical | |
Latitude: 41.080000 | |
Longitude: -81.620000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-02-01 | 213 LOMAK OPERATING CO GeoDate 2/1/80 |
Original Spud | 1980-09-22 | R.I. CHNG IN P.T.D. 8-8-80 |
Completed | 1980-09-26 | R.I. CHNG IN P.T.D. 8-8-80 |
Reached Total Depth | 1980-09-26 | R.I. CHNG IN P.T.D. 8-8-80 |
CO | 1992-03-05 | 1668 ENVIRONMENTAL EXP CO GeoDate 2/1/80 |
Change of Owner | 1999-10-14 | Operator changed from 1668, ENVIRONMENTAL EXP CO to 1388, NORTH COAST ENERGY INC |
Change of Owner | 2003-07-16 | Operator changed from 1388, NORTH COAST ENERGY INC to 4362, BUTLER KATHY |
Change of Owner | 2005-08-31 | Operator changed from 4362, BUTLER KATHY to 7902, WHITE ENERGY INC |
Change of Owner | 2016-07-13 | Operator changed from 7902, WHITE ENERGY INC to 5601, MOORE WELL SERVICES INC |
Change of Owner | 2019-05-28 | Operator changed from 5601, MOORE WELL SERVICES INC to 5569, D & D ENERGY COMPANY |
Record Last Modified | 2019-05-28 | R.I. CHNG IN P.T.D. 8-8-80 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3757 | 3802 | 14 |
3757 | 3802 | 14 | |
3757 | 3802 | 14 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 70000 Gal | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | APPALACHIAN EXPL INC | 9522.00 | 0.00 | 0 |
1985 | APPALACHIAN EXPL INC | 5879.00 | 31.00 | 334 |
1986 | APPALACHIAN EXPL INC | 5489.00 | 0.00 | 362 |
1987 | APPALACHIAN EXPL INC | 3218.00 | 121.00 | 365 |
1988 | APPALACHIAN EXPL INC | 2119.00 | 0.00 | 344 |
1989 | APPALACHIAN EXPL INC | 3045.00 | 0.00 | 365 |
1990 | RANGE OPERATING COMPANY | 2210.00 | 37.00 | 334 |
1992 | RANGE OPERATING COMPANY | 449.00 | 0.00 | 61 |
1993 | ENVIRONMENTAL EXP CO | 1547.00 | 0.00 | 365 |
1994 | ENVIRONMENTAL EXP CO | 1062.00 | 0.00 | 365 |
1995 | ENVIRONMENTAL EXP CO | 757.00 | 0.00 | 365 |
1996 | ENVIRONMENTAL EXP CO | 738.00 | 0.00 | 365 |
1997 | ENVIRONMENTAL EXP CO | 601.00 | 0.00 | 365 |
1998 | ENVIRONMENTAL EXP CO | 862.00 | 0.00 | 365 |
1999 | EXCO - NORTH COAST ENERGY INC | 5.00 | 0.00 | 91 |
2000 | EXCO - NORTH COAST ENERGY INC | 0.00 | 0.00 | 365 |
2001 | EXCO - NORTH COAST ENERGY INC | 0.00 | 0.00 | 365 |
2002 | EXCO - NORTH COAST ENERGY INC | 0.00 | 0.00 | 0 |
2003 | EXCO - NORTH COAST ENERGY INC | 0.00 | 0.00 | 0 |
2006 | WHITE ENERGY INC | 420.00 | 0.00 | 110 |
2007 | WHITE ENERGY INC | 775.00 | 0.00 | 365 |
2008 | WHITE ENERGY INC | 806.00 | 0.00 | 0 |
2009 | WHITE ENERGY INC | 925.00 | 0.00 | 365 |
2010 | WHITE ENERGY INC | 520.00 | 0.00 | 365 |
2012 | WHITE ENERGY INC | 763.00 | 0.00 | 366 |
2013 | WHITE ENERGY INC | 0.00 | 0.00 | 365 |
2014 | WHITE ENERGY INC | 128.00 | 0.00 | 365 |
2015 | WHITE ENERGY INC | 362.00 | 0.00 | 365 |
2016 | MOORE WELL SERVICES INC | 308.00 | 0.00 | 365 |
2017 | MOORE WELL SERVICES INC | 884.00 | 0.00 | 365 |
2018 | MOORE WELL SERVICES INC | 422.00 | 0.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-2070731188 | 2003-4-22 0:00: | PW | No Violations | |
0029779588 | 2002-09-12 | Production Wells | No Violations | CASE 02-032 - The Uniontown office received a complaint from the land owner (Mr. Wayne Arnold 330-666-1466) concerning two idle wells on his property, the Boss #1 and #2. The #1 well is owned by Murphy Oil. An inspection of the site indicated that the #2 well is shut in, the area surrounding the wellhead is overgrown and the stock tank, brine tank and separator are in disrepair. The last reported production from the Boss #2 was 1999. North Coast Energy is required to either produce or to properly plug and abandon this well. Prior to placing this well back into production, the structural integrity of the stock tank, brine tank and separator must be evaluated. |
0564473982 | 2006-04-18 | Production Wells | Violations Noted | Status check inspection found that the new tank battery has been placed too close to the well. The separator is approximately 15 from the well and the stock tank is 20 from the well. The tank battery must be moved and the required spacing maintained (50 from the well with 10 between the separator and the stock tank). |
1479387244 | 2016-11-15 | UrbanProduction Wells | No Violations | The Boss # 2 well was accessed on a two track field lane. The well was operated as a plunger lift well. I did not identify any leaks at the well head. The Operator was current in the reporting of production volumes. A current chart was hung on the gas measurement meter. The tank battery consisted of one (1) 100 barrel fluid tank, one (1) vertical separator and one (1) gas measurement meter. The I. D. signage reflected the new Operator and was legible. I did not identify any leaks at the tank battery during this inspection. No violations found during this inspection. |
2070731188 | 2003-04-22 | Production Wells | Violations Noted | CASE 02-032 The well is still idle and there has been no effort to either place the well back into production or to properly plug and abandon. I spoke with Andy (330-793-6974) regarding the well. He stated that he is either selling the well to Moore Well Service or Gas Acquisition to plug and abandon. He hopes to close on the sale by 05/15. An extension of this NOV is granted to 06/01. |
2085069026 | 2006-07-17 | Production Wells | Violations Noted | The spacing violation has been corrected and the well is in production. |
29779588 | 2002-9-12 0:00: | PW | No Violations | |
564473982 | 2006-4-18 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0564473982 | US-OH-126335 | 2006-04-27 | Violation of tank spacing requirements | |
0564473982 | US-OH-126336 | 2006-04-27 | Violation of separator spacing requirements | |
2070731188 | US-OH-121124 | 2002-09-17 | Well insufficiently equipped to prevent escape of oil and gas | |
2070731188 | US-OH-121125 | 2002-09-17 | Well shall be plugged | |
2085069026 | US-OH-121281 | 2006-04-27 | Violation of tank spacing requirements | |
2085069026 | US-OH-121282 | 2006-04-27 | Violation of separator spacing requirements |