X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-21196

Well Details

Well ID: 34-153-21196
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Copley Township
Operator Name: HARRISON ENERGY
Well Pad ID:
Farm/Lease Name: BAKO
License Status: Producing
License Date: 1982-08-10
Spud Date: 1982-08-31
Spud Drilling Contractor: WAYCO DRILLING
Final Drill Date: 1982-10-18
Well Total Depth: 3756.00 ft
Configuration: Vertical
Latitude: 41.130000
Longitude: -81.660000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-08-10 Issued Date 8/10/82 Expired Date 2/1/83 Acres 0020110 Tool Type CT Proposed Formation CLINTON Proposed Depth 03756 Proposed Drill Depth 03756
Original Spud 1982-09-05 PERMIT EXPIRED.
Completed 1982-10-18 PERMIT EXPIRED.
Reached Total Depth 1982-10-18 PERMIT EXPIRED.
CO 1982-11-18 646 COASTAL PETROLEUM CORP GeoDate 8/10/82
Construction Permit Expires 1983-02-01 PERMIT EXPIRED.
Completion Report Received 1985-05-13 PERMIT EXPIRED.
CO 1992-11-06 2348 TRIAD RESOURCES INC GeoDate 8/10/82
CO 1996-04-04 1217 HARRISON ENERGY GeoDate 8/10/82
Record Last Modified 2017-02-15 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3580 3664 0
3580 3664 0
2006-09-11 3600 3664 30
3600 3664 30
3580 3664 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 0 0 N2 FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 TRIAD RESOURCES INC 3034.00 350.00 365
1992 TRIAD RESOURCES INC 2941.00 303.00 365
1993 TRIAD RESOURCES INC 2067.00 0.00 305
1994 TRIAD RESOURCES INC 1529.00 0.00 365
1995 TRIAD RESOURCES INC 1290.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 TRIAD RESOURCES INC Brine 0 365
1992 TRIAD RESOURCES INC Brine 0 365
1993 TRIAD RESOURCES INC Brine 0 305
1994 TRIAD RESOURCES INC Brine 0 365
1995 TRIAD RESOURCES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-936390190 2004-4-15 0:00: PW No Violations
0936390190 2004-04-15 Production Wells No Violations FOLLOW UP TO NOV # 1083262237 Status check inspection. The last reported production was in 1995. It appears that the well is being used for domestic gas. If not, then the well must be placed back into production or plugged and abandoned. The tank battery equipment is in poor condition and needs to be repaired or replaced. The well identification is faded and also needs to be replaced.
1083262237 2004-04-15 Production Wells Violations Noted Status check inspection. The last reported production was in 1995. It appears that the well is being used for domestic gas. If not, then the well must be placed back into production or plugged and abandoned. The tank battery equipment is in poor condition and needs to be repaired or replaced. The well identification is faded and also needs to be replaced.
1409928835 2014-06-24 Production Wells Violations Noted I inspected the Bako # 1 on 6/24/2014 as a follow up to Chief Order # 2014 - 163 due to failure to obtain liability insurance. The last reported production for this well was in 1995, but sold a load ( approx. 130 Bbls. ) to Devco Oil Inc. on 3 / 14 / 2014. The well is operated by the pumping method. It is equipped with a pump jack, rods and 2.375 tubing. The well is pumped by an electrical motor. The main breaker in the electrcal box was in the off position at the time of my inspection. There are multiple domestic gas tie - ins connected to the 4.5 casing. I was told that 6 houses were supplied gas from the wellhead. The wellhead and fittings were leak free. I did not see any ground contamination around the pumping unit. The tank battery was comprised of 210 Bbl oil storage tank, a 100 bbl brine storage tank, a 25 bbl brine storage tank and a 2408 horizontal separator with a orifice gas meter. The fencing surrounding the tank battery was broken down to the ground in several places and the gate is nonfunctional. The required I.D. signage was incorrect and illegible. The 210 bbl oil stock tank was covered with oil from running the tank over. There is oil laying on the ground from the 210 bbl tank bottom leaking. The orifice gas meter has an old chart on it and I could not read the date it was last changed. Operator needs to file updated annual production, remove and remediate contaminated soil, remove or replace any leaking storage tanks, establish gas sales or flare any vented gas, install the required I.D. signage by 12/31/2014 or plug the well.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1083262237 US-OH-101885 2004-04-29 Failure to legibly identify well
1083262237 US-OH-101886 2004-04-29 Well shall be plugged
1409928835 US-OH-112068 2015-11-09 Well operation causing pollution and contamination
1409928835 US-OH-112069 2015-11-09 Failure to legibly identify well
1409928835 US-OH-112070 2015-11-09 Unlawful venting or flaring of gas
1409928835 US-OH-112071 2015-11-09 Well shall be plugged
1409928835 US-OH-112072 2015-11-09 Nonproduction; well shall be plugged or placed in temporary inactive status
1409928835 US-OH-112073 2015-11-09 Statement of annual production not filed

For data sources see[9]

References