Well ID: 34-153-21419
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: D & D ENERGY COMPANY
Well Pad ID:
Farm/Lease Name: BOKUN
License Status: Producing
License Date: 1984-04-25
Spud Date: 1984-06-15
Spud Drilling Contractor: CVAS DRLG
Final Drill Date: 1984-06-19
Well Total Depth: 3865.00 ft
Configuration: Vertical
Latitude: 41.270000
Longitude: -81.500000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-12-01 140 KST OIL & GAS CO INC GeoDate 12/1/83
Oil and Gas 1983-12-01 Issued Date 12/1/83 Expired Date 10/22/84 Acres 0023299 Tool Type CRAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1984-04-25 140 KST OIL & GAS CO INC GeoDate 4/25/84
Oil and Gas 1984-04-25 Issued Date 4/25/84 Expired Date 10/22/84 Acres 0023299 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03865 Proposed Drill Depth 03865
Original Spud 1984-06-15 R.I. 12-3-83, R.I. 4-28-84
Completed 1984-06-19 R.I. 12-3-83, R.I. 4-28-84
Reached Total Depth 1984-06-19 R.I. 12-3-83, R.I. 4-28-84
Completion Report Received 1984-08-08 R.I. 12-3-83, R.I. 4-28-84
Construction Permit Expires 1984-10-22 R.I. 12-3-83, R.I. 4-28-84
CO 1995-12-05 182 BELDEN & BLAKE CO GeoDate 4/25/84
Change of Owner 2001-05-24 Operator changed from 182, BELDEN & BLAKE CORPORATION to 5601, MOORE WELL SERVICES INC
Record Last Modified 2017-02-15 R.I. 12-3-83, R.I. 4-28-84

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3590 3694 0
3590 3694 0
2006-09-11 3638 3655 54
3638 3655 54
3590 3694 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 96000 Gal 0 FRAC: H2O

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 KST OIL & GAS CO INC 7061.00 104.00 365
1985 KST OIL & GAS CO INC 31822.00 321.00 365
1986 KST OIL & GAS CO INC 14545.00 161.00 365
1987 KST OIL & GAS CO INC 9433.00 99.00 365
1988 KST OIL & GAS CO INC 8241.00 48.00 365
1989 KST OIL & GAS CO INC 8387.00 56.00 365
1990 KST OIL & GAS CO INC 7169.00 54.00 365
1991 KST OIL & GAS CO INC 5032.00 59.00 365
1993 KST OIL & GAS CO INC 4608.00 48.00 365
1994 KST OIL & GAS CO INC 4216.00 54.00 365
1995 KST OIL & GAS CO INC 2532.00 0.00 365
1996 BELDEN & BLAKE CORPORATION 2830.00 66.00 364
1997 BELDEN & BLAKE CORPORATION 3054.00 0.00 344
1998 BELDEN & BLAKE CORPORATION 2480.00 56.00 323
1999 BELDEN & BLAKE CORPORATION 1250.00 0.00 258
2000 BELDEN & BLAKE CORPORATION 838.00 0.00 194
2001 MOORE WELL SERVICES INC 0.00 0.00 0
2002 MOORE WELL SERVICES INC 2065.00 0.00 351
2003 MOORE WELL SERVICES INC 2601.00 11.00 351
2004 MOORE WELL SERVICES INC 2316.00 18.00 365
2005 MOORE WELL SERVICES INC 2122.00 5.00 365
2006 MOORE WELL SERVICES INC 1911.00 10.00 357
2007 MOORE WELL SERVICES INC 1804.00 12.00 359
2008 MOORE WELL SERVICES INC 1802.00 5.00 365
2009 MOORE WELL SERVICES INC 1971.00 15.00 365
2010 MOORE WELL SERVICES INC 1751.00 0.00 365
2011 MOORE WELL SERVICES INC 1566.00 10.00 325
2012 MOORE WELL SERVICES INC 1578.00 10.00 366
2013 MOORE WELL SERVICES INC 1350.00 0.00 365
2014 MOORE WELL SERVICES INC 1203.00 15.00 365
2015 MOORE WELL SERVICES INC 2159.00 0.00 365
2016 MOORE WELL SERVICES INC 4673.00 11.00 365
2017 MOORE WELL SERVICES INC 2671.00 0.00 365
2018 MOORE WELL SERVICES INC 1662.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 KST OIL & GAS CO INC Brine 0 365
1985 KST OIL & GAS CO INC Brine 616 365
1986 KST OIL & GAS CO INC Brine 202 365
1987 KST OIL & GAS CO INC Brine 212 365
1988 KST OIL & GAS CO INC Brine 288 365
1989 KST OIL & GAS CO INC Brine 254 365
1990 KST OIL & GAS CO INC Brine 101 365
1991 KST OIL & GAS CO INC Brine 66 365
1993 KST OIL & GAS CO INC Brine 50 365
1994 KST OIL & GAS CO INC Brine 116 365
1995 KST OIL & GAS CO INC Brine 0 365
1996 BELDEN & BLAKE CORPORATION Brine 86 364
1997 BELDEN & BLAKE CORPORATION Brine 51 344
1998 BELDEN & BLAKE CORPORATION Brine 36 323
1999 BELDEN & BLAKE CORPORATION Brine 41 258
2000 BELDEN & BLAKE CORPORATION Brine 27 194
2001 MOORE WELL SERVICES INC Brine 40 0
2002 MOORE WELL SERVICES INC Brine 87 351
2003 MOORE WELL SERVICES INC Brine 351
2004 MOORE WELL SERVICES INC Brine 47 365
2005 MOORE WELL SERVICES INC Brine 113 365
2006 MOORE WELL SERVICES INC Brine 40 357
2007 MOORE WELL SERVICES INC Brine 97 359
2008 MOORE WELL SERVICES INC Brine 56 365
2009 MOORE WELL SERVICES INC Brine 21 365
2010 MOORE WELL SERVICES INC Brine 27 365
2011 MOORE WELL SERVICES INC Brine 35 325
2012 MOORE WELL SERVICES INC Brine 30 366
2013 MOORE WELL SERVICES INC Brine 365
2014 MOORE WELL SERVICES INC Brine 40 365
2015 MOORE WELL SERVICES INC Brine 1 365
2016 MOORE WELL SERVICES INC Brine 29 365
2017 MOORE WELL SERVICES INC Brine 0 365
2018 MOORE WELL SERVICES INC Brine 10 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0472102403 2007-06-14 Production Wells No Violations The Uniontown office received a request from Atty. Bill Williams to inspect this site for his client, the property owner. The owner plans to develop the property and was concerned about the flowline depth and location. My inspection found that the flowline is buried from the wellhead to the intersection with the Buckeye and North Coast transmission pipelines. The depth of burial was approximately 12 to 18 inches, where it could be determined. The flowline is exposed at the surface from the transmission pipelines to the Moore tank battery. OAC 1501:9-10-05 allows for burial exemptions in certain cases. In this case, 1) it is not reasonably expected that the property would be cultivated and 2) the potential negative environmental impact from encountering the high pressure/high volume transmission pipelines is greater than the potential environmental impact from the 2 inch flowline. According to Bob Moore, the two parties have been in negotiations to relocate the flowline in order to minimize the contact with the proposed site development.
472102403 2007-6-14 0:00: PW No Violations

For data sources see[9]