34-153-21489

Well Details

Well ID: 34-153-21489
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Bath Township
Operator Name: PINE TOP INC
Well Pad ID:
Farm/Lease Name: ARTHUR
License Status: Producing
License Date: 1983-08-19
Spud Date: 1983-10-01
Spud Drilling Contractor: MARTIN DRILLING
Final Drill Date: 1983-10-07
Well Total Depth: 3781.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -81.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-08-19 570 PINE TOP INC GeoDate 8/19/83
Oil and Gas 1983-08-19 Issued Date 8/19/83 Expired Date 2/15/84 Acres 0020000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03781 Proposed Drill Depth 03781
Original Spud 1983-10-01
Completed 1983-10-07
Reached Total Depth 1983-10-07
Completion Report Received 1984-01-03
Construction Permit Expires 1984-02-15
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3599 3688 0
3599 3688 0
2006-09-11 3605 3655 37
3605 3655 37
3599 3688 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1418 Bbl 60000 FRAC: WATER, SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 PINE TOP INC 17195.00 5806.00 0
1985 PINE TOP INC 23835.00 3750.00 0
1988 PINE TOP INC 7880.00 725.00 365
1989 PINE TOP INC 9170.00 223.00 365
1990 PINE TOP INC 6497.00 354.00 365
1991 PINE TOP INC 5014.00 161.00 365
1992 PINE TOP INC 2779.00 224.00 365
1993 PINE TOP INC 2478.00 123.00 365
1994 PINE TOP INC 7622.00 516.00 365
1995 PINE TOP INC 2520.00 170.00 371
1996 PINE TOP INC 3736.00 324.00 353
1997 PINE TOP INC 3499.00 244.00 365
1998 PINE TOP INC 1269.00 50.00 365
1999 PINE TOP INC 1416.00 120.00 365
2000 PINE TOP INC 1021.00 77.00 365
2001 PINE TOP INC 2648.00 138.00 365
2002 PINE TOP INC 2259.00 189.00 365
2003 PINE TOP INC 2719.00 110.00 365
2004 PINE TOP INC 1448.00 82.00 365
2005 PINE TOP INC 1003.00 28.00 365
2006 PINE TOP INC 2169.00 118.00 365
2007 PINE TOP INC 2090.00 100.00 365
2009 PINE TOP INC 121.00 0.00 365
2010 PINE TOP INC 0.00 0.00 365
2011 PINE TOP INC 0.00 0.00 365
2012 PINE TOP INC 420.00 0.00 366
2013 PINE TOP INC 444.00 75.00 365
2014 PINE TOP INC 724.00 0.00 365
2015 PINE TOP INC 474.00 0.00 365
2016 PINE TOP INC 452.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 PINE TOP INC Brine 63 0
1985 PINE TOP INC Brine 235 0
1988 PINE TOP INC Brine 56 365
1989 PINE TOP INC Brine 95 365
1990 PINE TOP INC Brine 131 365
1991 PINE TOP INC Brine 63 365
1992 PINE TOP INC Brine 80 365
1993 PINE TOP INC Brine 36 365
1994 PINE TOP INC Brine 145 365
1995 PINE TOP INC Brine 0 371
1996 PINE TOP INC Brine 40 353
1997 PINE TOP INC Brine 35 365
1998 PINE TOP INC Brine 50 365
1999 PINE TOP INC Brine 0 365
2000 PINE TOP INC Brine 50 365
2001 PINE TOP INC Brine 0 365
2002 PINE TOP INC Brine 45 365
2003 PINE TOP INC Brine 0 365
2004 PINE TOP INC Brine 0 365
2005 PINE TOP INC Brine 0 365
2006 PINE TOP INC Brine 70 365
2007 PINE TOP INC Brine 160 365
2009 PINE TOP INC Brine 0 365
2010 PINE TOP INC Brine 0 365
2011 PINE TOP INC Brine 0 365
2012 PINE TOP INC Brine 50 366
2013 PINE TOP INC Brine 0 365
2014 PINE TOP INC Brine 0 365
2015 PINE TOP INC Brine 0 365
2016 PINE TOP INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1822191003 2005-1-13 0:00: PW No Violations
0125240560 2019-04-04 Production Wells No Violations My inspection found the operator did not correct the compliance issues cited in the Compliance Notice issued on 05-24-16. The compliance issues are as follows: The well is not legibly identified andThe separator has not been moved to the minimum distance of 50 ft. from the wellhead. The contamination at the brine drain was not located. The well is equipped with a pumpjack and all the valves are in the closed position. The tubing head is leaking gas. The fence is no longer locked at the well entry. The tank battery consists of a steel production tank, a steel brine tank, a vertical separator and a meter without a chart.
125240560 2019-4-4 0:00:0 PW No Violations 0.80
1756841371 2016-05-17 UrbanProduction Wells Violations Noted The Arthur # 1 well was completed in 10 1983. The well was constructed with 402 of 8.625 surface casing and 3767 of 4.5 production casing. A review of the RBDMS data base indicated that the Operator has not reported production volumes for the calendar year of 2015. Access was gained through a locked gate off of Shade Road. The tank battery consisted of a 100 barrel oil tank, 50 barrel brine tank, vertical separator and a gas measurement meter ( no chart ). The separator was 30 from the wellhead and shall be moved to a minimum of 50 per 1501:9-9-05 OAC. The tank battery was fenced, locked and surrounded by an earthen dike. The load lines were secured with flat plugs. There was ground contamination at the brine drain. The required I.D. signage did not have the current emergency contact number. Two ( 2) joints of pipe were laying outside the tank battery. The fencing for the tank battery continues around to encompass the wellhead. The well is operated as an electric pump jack. The well was overgrown with vegetation and restricting access. The well appeared to have parted rods as there was 50 of polished rod exposed on a unit that had a 42 stroke length. The pumpingunit had not been operable for an extended period of time as evidenced by the trees growing up through the belts. In order to bring the Arthur #1 well into compliance the Owner shall : 1.) Post the I.D. signage with the current contact information, 2.) Report production volumes for the year of 2015, 3.) remove and replace contaminated soil and gravel at the brine drain, 4.) remove all piping and equipment not instrumental to production activities, 5.) Owner shall move separator to a distance from the wellhead that is compliant with 1501:9-9-05. The Owner shall contact the DOGRM Inspector Bob Roush within five (5) days after receiving this Notice of Compliance.
1822191003 2005-01-13 Production Wells No Violations No violations at this time.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1756841371 US-OH-117478 2016-06-20 ID (a-i)
1756841371 US-OH-117479 2016-06-20 Well operation causing pollution and contamination
1756841371 US-OH-117480 2016-06-20 Violation of separator spacing requirements

For data sources see[9]