X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-21781

Well Details

Well ID: 34-153-21781
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Bath Township
Operator Name: D & D ENERGY COMPANY
Well Pad ID:
Farm/Lease Name: BRB PROPERTIES UNIT
License Status: Producing
License Date: 2000-12-29
Spud Date: 1984-05-01
Spud Drilling Contractor: CHM DRLG
Final Drill Date: 1984-05-05
Well Total Depth: 3570.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -81.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-03-16 70 WALDRON DAVID A & ASS INC GeoDate 3/16/84
Oil and Gas 1984-03-16 Issued Date 3/16/84 Expired Date 9/12/84 Acres 0020700 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03570 Proposed Drill Depth 03570
Original Spud 1984-05-01
Completed 1984-05-05
Reached Total Depth 1984-05-05
Completion Report Received 1984-05-17
APP 2000-12-29 Proposed Formations:CLINTON, Issued Date:12/29/2000, Expired Date:12/29/2001 6:00:00 AM, Drilling unit acres:20.7, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2001-12-29
Change of Owner 2016-10-11 Operator changed from 70, DAVID A WALDRON & ASSOC to 9722, PIN OAK ENERGY PARTNERS LLC
Change of Owner 2018-07-09 Operator changed from 9722, PIN OAK ENERGY PARTNERS LLC to 5569, D & D ENERGY COMPANY
Record Last Modified 2018-07-09

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3401 3446 22
3401 3446 22
3401 3446 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 70000 Gal 40000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DAVID A WALDRON & ASSOC 5327.00 0.00 0
1985 DAVID A WALDRON & ASSOC 5523.00 48.00 365
1986 DAVID A WALDRON & ASSOC 6192.00 41.00 365
1987 DAVID A WALDRON & ASSOC 6226.00 0.00 365
1988 DAVID A WALDRON & ASSOC 2385.00 0.00 365
1989 DAVID A WALDRON & ASSOC 4408.00 0.00 365
1990 DAVID A WALDRON & ASSOC 3788.00 0.00 365
1991 DAVID A WALDRON & ASSOC 3676.00 0.00 365
1992 DAVID A WALDRON & ASSOC 2370.00 51.00 365
1993 DAVID A WALDRON & ASSOC 2522.00 0.00 365
1995 DAVID A WALDRON & ASSOC 2133.00 0.00 365
1996 DAVID A WALDRON & ASSOC 2650.00 0.00 365
1997 DAVID A WALDRON & ASSOC 3084.00 0.00 365
1998 DAVID A WALDRON & ASSOC 2117.00 0.00 365
1999 DAVID A WALDRON & ASSOC 1559.00 0.00 365
2000 DAVID A WALDRON & ASSOC 1307.00 0.00 365
2001 DAVID A WALDRON & ASSOC 1096.00 0.00 365
2002 DAVID A WALDRON & ASSOC 1257.00 0.00 365
2003 DAVID A WALDRON & ASSOC 1187.00 0.00 365
2004 DAVID A WALDRON & ASSOC 1085.00 0.00 365
2005 DAVID A WALDRON & ASSOC 852.00 0.00 365
2006 DAVID A WALDRON & ASSOC 991.00 0.00 365
2007 DAVID A WALDRON & ASSOC 1073.00 0.00 365
2008 DAVID A WALDRON & ASSOC 839.00 0.00 365
2009 DAVID A WALDRON & ASSOC 785.00 0.00 365
2010 DAVID A WALDRON & ASSOC 458.00 0.00 365
2011 DAVID A WALDRON & ASSOC 147.00 0.00 365
2012 DAVID A WALDRON & ASSOC 1076.00 0.00 366
2013 DAVID A WALDRON & ASSOC 956.00 23.00 365
2014 DAVID A WALDRON & ASSOC 955.00 0.00 365
2015 DAVID A WALDRON & ASSOC 869.00 0.00 365
2016 DAVID A WALDRON & ASSOC 281.00 0.00 365
2017 PIN OAK ENERGY PARTNERS LLC 0.00 0.00 0
2018 D & D ENERGY COMPANY 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DAVID A WALDRON & ASSOC Brine 0 0
1985 DAVID A WALDRON & ASSOC Brine 373 365
1986 DAVID A WALDRON & ASSOC Brine 298 365
1987 DAVID A WALDRON & ASSOC Brine 145 365
1988 DAVID A WALDRON & ASSOC Brine 152 365
1989 DAVID A WALDRON & ASSOC Brine 254 365
1990 DAVID A WALDRON & ASSOC Brine 168 365
1991 DAVID A WALDRON & ASSOC Brine 141 365
1992 DAVID A WALDRON & ASSOC Brine 154 365
1993 DAVID A WALDRON & ASSOC Brine 44 365
1995 DAVID A WALDRON & ASSOC Brine 0 365
1996 DAVID A WALDRON & ASSOC Brine 73 365
1997 DAVID A WALDRON & ASSOC Brine 159 365
1998 DAVID A WALDRON & ASSOC Brine 160 365
1999 DAVID A WALDRON & ASSOC Brine 137 365
2000 DAVID A WALDRON & ASSOC Brine 154 365
2001 DAVID A WALDRON & ASSOC Brine 151 365
2002 DAVID A WALDRON & ASSOC Brine 161 365
2003 DAVID A WALDRON & ASSOC Brine 238 365
2004 DAVID A WALDRON & ASSOC Brine 161 365
2005 DAVID A WALDRON & ASSOC Brine 80 365
2006 DAVID A WALDRON & ASSOC Brine 240 365
2007 DAVID A WALDRON & ASSOC Brine 160 365
2008 DAVID A WALDRON & ASSOC Brine 140 365
2009 DAVID A WALDRON & ASSOC Brine 210 365
2010 DAVID A WALDRON & ASSOC Brine 70 365
2011 DAVID A WALDRON & ASSOC Brine 0 365
2012 DAVID A WALDRON & ASSOC Brine 294 366
2013 DAVID A WALDRON & ASSOC Brine 135 365
2014 DAVID A WALDRON & ASSOC Brine 173 365
2015 DAVID A WALDRON & ASSOC Brine 180 365
2016 PIN OAK ENERGY PARTNERS LLC Brine 0 365
2017 PIN OAK ENERGY PARTNERS LLC Brine 0 0
2018 D & D ENERGY COMPANY Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0809191807 2016-10-18 UrbanProduction Wells No Violations I re-inspected the BRB Properties Unit # 1 as a follow up to Compliance Notice # 1530884821 which noted noncompliance of a 100 barrel stock with holes and a screen fencing which had fallen into disrepair and posed a safety hazard. My follow up inspection determine that all items ( tank and fencing ) had removed, cleaned up and brought the BRB Property Unit # 1 into compliance.
1530884821 2016-04-28 UrbanProduction Wells Violations Noted The BRB Properties Unit # 1 was drilled and completed in 5/1984. The well was constructed with 408 of 8.625 surface casing and 3552 of 4.5 production casing. A review of the RBDMS data base indicated that the Operator is current in the reporting of the volumes of oil, gas and brine produced. I spoke with Irene Tramonte ( landowner ) about her concerns of the condition of the wood fencing and the holes in the oil tank. The well was equipped as an electrified pumping well. The wellhead was secured with a locked chain link fence. The wellhead was free from leaks or contamination at the time of my inspection. There is a wood stockade fence which was initially purposed for a screening effect, but is in disrepair and falling down surrounding both the wellhead and tank battery. The Landowner expressed concern for her grandchildren exploring around this fencing and getting injured. The tank battery was comprised of two ( 2 ) 100 barrel stock tanks, a horizontal separator and a domestic house connection and was secured by a chain link fence and locked access door.. There was the required I.D. signage present, but was obscured by the stockade screening. The load lines were secured with flat plugs. The southern 100 barrel stock tank had deteriorated to the point where a large hole ( 2 X 2 ) and other associated smaller holes has previously caused ground contamination. The tank battery is located approximately 135 south of the Yellow Creek stream bed and local drainage is northeast toward the stream. The tank shall require removal and the contaminated soil underneath removed and replaced. The other 100 barrel stock tank appeared to be liquid tight at the time of my inspection. The stockade screening needs to be removed as it was an impediment to gain access and is a safety hazard. In order to bring the BRB Properties Unit # 1 into compliance the Owner shall remove the defective 100 barrel tank and remedial the tank battery pad under the tank. The wood stockade screening shall
2084854016 2016-06-06 UrbanProduction Wells No Violations I conducted a follow up inspection in response to the Notice of Violation # 1530884821 detailing violations regarding a screening fence ( General Safety 1501:9-9-02 ) in disrepair and well operation causing pollution and contamination ( 100 barrel oil tank with holes 1501:9-1-07 ). I observed that the screening fence had been removed, but the offending 100 barrel tank was still on location. I spoke with Ted Cutwright ( D.A. Waldron & Associates foreman ) who said, he was waiting for a steam truck to clean the tank before removal. He offered the time frame for removal by weeks end. The violation for general safety has been brought into compliance. The violation for well operation causing pollution and contamination remains in effect.
2147067137 2016-10-18 UrbanProduction Wells No Violations A follow up inspection was conducted in order to assess whether the Operator had completed the required remedies as prescribed in the previous Notice of Violation ( # 1530884821 ) dated 4/28/2016. The violations concerned General Safety ( 1501:9-9-02 ) which was corrected previously and the remaining violation, Well operation causing pollution and contamination ( 1501:9-1-07 ), as the 100 barrel oil tank had holes on the sides. I observed that the 100 barrel tank had been removed from the tank battery. The previous Notice of Violation had been completely satisfied
809191807 2016-10-18 0:00 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1530884821 US-OH-114689 2016-06-20 Well operation causing pollution and contamination
1530884821 US-OH-114690 2016-06-20 General Safety

For data sources see[9]

References