X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-21814

Well Details

Well ID: 34-153-21814
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: WINEBERG MELVIN P
Well Pad ID:
Farm/Lease Name: HARP / FLEMING UNIT
License Status: Domestic Well
License Date: 1985-08-21
Spud Date: 1985-09-13
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1985-09-16
Well Total Depth: 3857.00 ft
Configuration: Vertical
Latitude: 41.060000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-05-03 Issued Date 5/3/84 Expired Date 10/30/84 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1985-08-21 198 VIKING RESOURCES CORP GeoDate 8/21/85
Oil and Gas 1985-08-21 Issued Date 8/21/85 Expired Date 8/21/86 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03857 Proposed Drill Depth 03857
Original Spud 1985-09-13 RI 8-24-85
Completed 1985-09-16 RI 8-24-85
Reached Total Depth 1985-09-16 RI 8-24-85
CO 1986-01-23 198 VIKING RESOURCES CORP GeoDate 5/3/84
Completion Report Received 1986-02-06 RI 8-24-85
Construction Permit Expires 1986-08-21 RI 8-24-85
Change of Owner 1998-11-30 Operator changed from 198, VIKING RESOURCES CORP to 5569, D & D ENERGY COMPANY
Change of Owner 2006-10-18 Operator changed from 5569, D & D ENERGY COMPANY to 6349, WINEBERG MELVIN P
Record Last Modified 2017-02-15 RI 8-24-85

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3640 3750 0
3640 3750 0
2006-09-11 3686 3737 15
3686 3737 15
3640 3750 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 633 Bbl 50000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 VIKING RESOURCES LLC 2489.00 22.00 0
2004 D & D ENERGY COMPANY 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 VIKING RESOURCES LLC Brine 152 0
2004 D & D ENERGY COMPANY Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0749993540 2017-06-05 Production Wells Violations Noted I was contacted by the State Fire Marshals office in regards to this well. There was an explosion at the winery on the property and they were investigating the cause and were inquiring about the domestic well on the property. At the time of my inspection I meet with Andy Troutman, current landowner of the property that the well is located on. Andy Troutman, Terry Whitehair DOGRM Emergency Response Coordinator and Fred Romeo DOGRM Emergency Coordinator accompanied me on the inspection. The well has 4.5 inch casing exposed at surface with a tubing head attached to it. The 1.5 inch tubing remains in the well. A domestic supply is plumbed off of the 4.5 inch casing. There was a drip on the domestic supply. Andy stated that last time he blew the drip down there was just a mist that came out of it. The domestic supply was turned off. There was a poly tank adjacent to the well that Andy stated was what they swabbed into when the well was swabbed. The last time the well was swabbed was approximately 7 years ago. There was approximately one foot of fluid in the poly tank. The well is registered to Melvin Wineberg who according to Andy is deceased. Andy stated the well was part of the sale of the property. I informed Andy that the following needs to be completed: Andy Troutman needs to become the registered owner of the well before it is put back into production. Identification needs to be posted at the wellhead. It was suggested that Andy hire a qualified well service company to asses the domestic supply coming off of the well before it is utilized again and consider installing a positive drip shut off.
1567537471 2019-9-3 0:00:0 PW No Violations 1.00
749993540 2017-6-5 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0749993540 US-OH-128528 2017-09-25 Failure to legibly identify well
0749993540 US-OH-128529 2017-09-25 Failure to notify MRM of assignment or transfer of wells

For data sources see[9]

References