X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-21943

Well Details

Well ID: 34-153-21943
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PINE TOP INC
Well Pad ID:
Farm/Lease Name: CONTI UNIT
License Status: Producing
License Date: 1984-08-27
Spud Date: 1984-10-24
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1984-10-29
Well Total Depth: 3719.00 ft
Configuration: Vertical
Latitude: 41.150000
Longitude: -81.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-08-27 182 BELDEN & BLAKE CO GeoDate 8/27/84
Oil and Gas 1984-08-27 Issued Date 8/27/84 Expired Date 2/23/85 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03719 Proposed Drill Depth 03719
Original Spud 1984-10-24 FDT=LOWER
Completed 1984-10-29 FDT=LOWER
Reached Total Depth 1984-10-29 FDT=LOWER
Completion Report Received 1985-02-07 FDT=LOWER
Construction Permit Expires 1985-02-23 FDT=LOWER
CO 1995-06-14 570 PINE TOP INC GeoDate 8/27/84
Record Last Modified 2017-02-15 FDT=LOWER

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3580 3666 0
3580 3666 0
2006-09-11 3606 3666 18
3606 3666 18
3580 3666 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 51500 Gal 30000
ACID 0 500 Gal 0 FRAC:WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 BELDEN & BLAKE CORPORATION 9694.00 581.00 234
1990 BELDEN & BLAKE CORPORATION 3558.00 266.00 274
1991 BELDEN & BLAKE CORPORATION 1564.00 85.00 365
1992 BELDEN & BLAKE CORPORATION 998.00 0.00 366
1993 BELDEN & BLAKE CORPORATION 706.00 0.00 365
1994 BELDEN & BLAKE CORPORATION 41.00 0.00 152
1995 BELDEN & BLAKE CORPORATION 0.00 98.00 98
1997 PINE TOP INC 758.00 244.00 365
1998 PINE TOP INC 0.00 0.00 365
1999 PINE TOP INC 0.00 0.00 0
2000 PINE TOP INC 0.00 0.00 0
2001 PINE TOP INC 0.00 0.00 0
2002 PINE TOP INC 0.00 0.00 365
2003 PINE TOP INC 0.00 0.00 0
2004 PINE TOP INC 0.00 0.00 0
2005 PINE TOP INC 107.00 28.00 0
2006 PINE TOP INC 0.00 0.00 0
2007 PINE TOP INC 9.00 0.00 0
2009 PINE TOP INC 563.00 0.00 0
2010 PINE TOP INC 126.00 0.00 365
2011 PINE TOP INC 0.00 0.00 365
2012 PINE TOP INC 0.00 0.00 0
2013 PINE TOP INC 0.00 0.00 0
2014 PINE TOP INC 0.00 0.00 0
2015 PINE TOP INC 0.00 0.00 0
2016 PINE TOP INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 BELDEN & BLAKE CORPORATION Brine 72 234
1990 BELDEN & BLAKE CORPORATION Brine 21 274
1991 BELDEN & BLAKE CORPORATION Brine 49 365
1992 BELDEN & BLAKE CORPORATION Brine 5 366
1993 BELDEN & BLAKE CORPORATION Brine 9 365
1994 BELDEN & BLAKE CORPORATION Brine 0 152
1995 BELDEN & BLAKE CORPORATION Brine 62 98
1997 PINE TOP INC Brine 102 365
1998 PINE TOP INC Brine 0 365
1999 PINE TOP INC Brine 0 0
2000 PINE TOP INC Brine 0 0
2001 PINE TOP INC Brine 0 0
2002 PINE TOP INC Brine 0 365
2003 PINE TOP INC Brine 0 0
2004 PINE TOP INC Brine 0 0
2005 PINE TOP INC Brine 0 0
2006 PINE TOP INC Brine 0 0
2007 PINE TOP INC Brine 0 0
2009 PINE TOP INC Brine 0 0
2010 PINE TOP INC Brine 0 365
2011 PINE TOP INC Brine 0 365
2012 PINE TOP INC Brine 0 0
2013 PINE TOP INC Brine 0 0
2014 PINE TOP INC Brine 0 0
2015 PINE TOP INC Brine 0 0
2016 PINE TOP INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-143070047 2005-6-30 0:00: PW No Violations
-1862930622 2017-9-5 0:00:0 TD No Violations
0000PL4440 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0143070047 2005-06-30 Production Wells Violations Noted The well has been placed back into production and the violation has been corrected. The land owner has received a royalty check.
1108738146 2005-02-09 Production Wells Violations Noted Status check inspection of Pine Top wells in the Northampton area. This concoil well is idle with the last reported production in 1997. The tank battery also lacks the required identification. The well must either be placed back into production or properly plugged and abandoned. The required ID must be posted at both the wellhead and the tank battery.
1556541873 2019-04-25 Production Wells Violations Noted My inspection found this is a swab well. The well last produced in 2010 for 126 MCF of gas. There was zero production for 2011 through 2016 and there is no Annual Production Report for 2017. There is gas leaking from the casing head. The tank battery consists of two 210-barrel tanks - one tank is not plumbed in, a steel brine tank laid over on its side, a horizontal separator and a meter. There is a disconnected 210-barrel tank outside of the dike. There is a domestic gas connection. The dike is shared with the tank battery for well #153-21632. The well is not legibly identified. The well is idle. Consequently, the well is in violation of Revised code 1509.062 and shall be plugged in accordance with Ohio Revised Code section 1509.12 (B). The well owner/operator shall submit a written plugging schedule to Shawn Murphy at 3575 Forest Lake Dr., Ste. 150, Uniontown, Ohio 44685 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
183343396 2020-10-28 0:00 UP No Violations 1.50
1862930622 2017-09-05 Temporary Abandoned Annular Disposal No Violations The Conti # 1 was operated as a Casing Plunger Lift ( ConCoyle ) well. The was not any connection with the annular space to allow annular disposal. The tank battery consisted of one (1) 210 barrel stock tank, horizontal separator and gas meter. An earthen dike surrounded the tank battery. This tank battery was a shared facility. The signage was worn and torn but legible. The last reported production volumes was for the year 2010.
1991269019 2017-09-05 Temporary Abandoned Annular Disposal No Violations The Bonner # 2 was operated as an electric pumping well. The well head was surrounded by a locked chain link fence. The required I D signage was posted.I did not identify any connection with the 8.625 surface casing annular space for annular disposal. No annular disposal.
919864135 2020-2-6 0:00:0 UP No Violations 1.00
PL4440 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0143070047 US-OH-112580 2005-02-18 Failure to legibly identify well
0143070047 US-OH-112581 2005-02-18 Well shall be plugged
1108738146 US-OH-102689 2005-02-18 Failure to legibly identify well
1108738146 US-OH-102690 2005-02-18 Well shall be plugged
1556541873 US-OH-115163 2019-04-29 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
1556541873 US-OH-115164 2019-04-29 9-9-05(A)10 Failure to legibly identify well
1556541873 US-OH-115165 2019-04-29 NONE Well shall be plugged

For data sources see[9]

References