X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-22854

Well Details

Well ID: 34-153-22854
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Bath Township
Operator Name: ST CROIX LTD
Well Pad ID:
Farm/Lease Name: MENARD
License Status: Producing
License Date: 1996-12-10
Spud Date: 1997-12-09
Spud Drilling Contractor: GREY WOLF DRILLING
Final Drill Date: 1997-12-16
Well Total Depth: 3860.00 ft
Configuration: Directional
Latitude: 41.160000
Longitude: -81.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1996-12-10 2364 ST CROIX LTD GeoDate 12/10/96
Oil and Gas 1996-12-10 Issued Date 12/10/96 Expired Date 12/10/97 Acres 0020810 Tool Type RTAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth
Original Spud 1997-12-09 PERMIT EXPIRED.
Construction Permit Expires 1997-12-10 PERMIT EXPIRED.
Completed 1997-12-16 PERMIT EXPIRED.
Reached Total Depth 1997-12-16 PERMIT EXPIRED.
Completion Report Received 2002-12-24 PERMIT EXPIRED.
Record Last Modified 2019-06-14 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-12-26 3558 3631 59
3558 3631 59
3558 3631 59

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 48400 Gal 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 ST CROIX LTD 518.00 207.00 130
2003 ST CROIX LTD 1742.00 442.00 365
2004 ST CROIX LTD 1627.00 317.00 365
2005 ST CROIX LTD 1326.00 293.00 365
2006 ST CROIX LTD 1318.00 217.00 365
2007 ST CROIX LTD 1444.00 211.00 365
2008 ST CROIX LTD 1275.00 173.00 365
2009 ST CROIX LTD 1205.00 145.00 365
2010 ST CROIX LTD 1138.00 132.00 365
2011 ST CROIX LTD 1139.00 102.00 365
2012 ST CROIX LTD 1070.00 112.00 366
2013 ST CROIX LTD 1036.00 108.00 365
2014 ST CROIX LTD 782.00 63.00 365
2015 ST CROIX LTD 552.00 0.00 365
2016 ST CROIX LTD 0.00 0.00 0
2017 ST CROIX LTD 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 ST CROIX LTD Brine 754 130
2003 ST CROIX LTD Brine 208 365
2004 ST CROIX LTD Brine 81 365
2005 ST CROIX LTD Brine 649 365
2006 ST CROIX LTD Brine 114 365
2007 ST CROIX LTD Brine 54 365
2008 ST CROIX LTD Brine 40 365
2009 ST CROIX LTD Brine 70 365
2010 ST CROIX LTD Brine 0 365
2011 ST CROIX LTD Brine 33 365
2012 ST CROIX LTD Brine 35 366
2013 ST CROIX LTD Brine 35 365
2014 ST CROIX LTD Brine 91 365
2015 ST CROIX LTD Brine 40 365
2016 ST CROIX LTD Brine 0 0
2017 ST CROIX LTD Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1138897452 2003-1-31 0:00: PW No Violations
0074553612 2017-12-28 UrbanProduction Wells No Violations Access was graveled to the tank battery and halfway to the wellhead. The tank battery consisted of one (1) 210 bbl stock tank, one (1) 100 bbl steel brine tank, one (1) horizontal separator and a small electric natural gas compressor. The tank battery was fenced and locked.The load lines were plugged but not locked. I did not identify any leaks at the tank battery. A Dominion Resources gas meter had a paper chart which reflected the current production period, but was not indicating any gas sales. The RBDMS data system had 0 listed for volumes of gas, oil and brine for the year 2016. The well was operated as a electric pumping unit. The wellhead was fenced and locked. I did not see any leaks at the wellhead. The signage at the wellhead and tank battery has faded and will require remarking. I placed a call to the Operator. I requested a phone call back. Preliminary restoration was due and the location met the requirements. Preliminary restoration was passed.
1038624028 2002-11-18 Production Wells Violations Noted The site was inspected at the request of the Bath zoning inspector. The well was drilled in 1997 but it appears that the tank battery has just recently been set and neither the well nor the tank battery have any identification. St Croix has also never reported production from this well. Several calls to the operator were not answered. I will continue to attempt the contact the operator for clarification.
1046286706 2003-02-25 Production Wells No Violations The signage violation has been corrected. No violations at this time.
1138897452 2003-01-31 Production Wells Violations Noted The requested signage has not been posted. Spoke with St. Croix about the issue which they will address as soon as the weather permits.
1701364041 2003-09-23 Production Wells No Violations Status check inspection - no violations at this time.
74553612 2017-12-28 0:00 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1038624028 US-OH-100360 2002-11-29 Failure to legibly identify well
1138897452 US-OH-103515 2002-11-29 Failure to legibly identify well

For data sources see[9]

References