Well Details

Well ID: 34-153-23110
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: INDUSTRY STANDARD SUPPLIES INC
Well Pad ID:
Farm/Lease Name: MESSNER UNIT
License Status: Producing
License Date: 2010-05-18
Spud Date: 2010-06-26
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2010-06-30
Well Total Depth: 3976.00 ft
Configuration: Vertical
Latitude: 41.040000
Longitude: -81.660000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-05-18 Proposed Formations:CLINTON, Issued Date:5/18/2010, Expired Date:5/18/2011 6:00:00 AM, Drilling unit acres:22.8, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-06-30
Completion Report Received 2010-11-15
Construction Permit Expires 2011-05-18
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-02-18 3730 3750 42
3730 3750 42
3730 3750 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-07-30 H2O 15 72000 Gal 15000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 INDUSTRY STANDARD SUPPLIES INC 531.00 1030.00 273
2011 INDUSTRY STANDARD SUPPLIES INC 9740.00 2396.00 365
2012 INDUSTRY STANDARD SUPPLIES INC 7955.00 1422.00 366
2013 INDUSTRY STANDARD SUPPLIES INC 6495.00 1121.00 365
2014 INDUSTRY STANDARD SUPPLIES INC 5999.00 869.00 365
2015 INDUSTRY STANDARD SUPPLIES INC 6132.00 759.00 365
2016 INDUSTRY STANDARD SUPPLIES INC 5200.00 585.00 365
2017 INDUSTRY STANDARD SUPPLIES INC 4540.00 559.00 365
2018 INDUSTRY STANDARD SUPPLIES INC 4277.00 452.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 INDUSTRY STANDARD SUPPLIES INC Brine 0 273
2011 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2012 INDUSTRY STANDARD SUPPLIES INC Brine 0 366
2013 INDUSTRY STANDARD SUPPLIES INC Brine 66 365
2014 INDUSTRY STANDARD SUPPLIES INC Brine 66 365
2015 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2016 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2017 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2018 INDUSTRY STANDARD SUPPLIES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1110655664 2010-8-24 0:00: UD No Violations
-1116802606 2018-5-1 0:00:0 UP No Violations
-1341664078 2010-7-15 0:00: DD No Violations
-1711214410 2010-8-3 0:00:0 DD No Violations
-1780373710 2010-7-13 0:00: DD No Violations
-1781263288 2010-7-28 0:00: DD No Violations
-722294385 2010-6-29 0:00: DD No Violations
0294142591 2010-08-12 Drill / Deepen / Reopen No Violations Chem Tech was on site with two loads of dust to solidify the two drilling pits. No violations at this time.
0672637003 2010-07-30 Drill / Deepen / Reopen No Violations Appalachian Well Surveys was on site to a run cement bond log and perforate the Clinton. The bond log indicated that the top of cement and bond quality was sufficient to proceed with the frac job scheduled for this afternoon. The drilling pits are still open.
0722294385 2010-06-29 Drill / Deepen / Reopen No Violations Poulson is drilling ahead on air/soap. The pits are fenced, lined and in good condition with sifficient freeboard.
0948314177 2011-01-25 UrbanProduction Wells No Violations The well is in production. Preliminary restoration will be evaluated as soon as the snow cover is gone and the site can be inspected. A recent water well complaint from a resident at 3201 Hametown Road has been resolved. The analytical results of the water collected by MRM do not indicate any oilfield involvement.
1076212163 2010-07-06 Drill / Deepen / Reopen No Violations Poulson Drilling has moved off location. The pits are fenced, lined and in good condition. They have been pumped down and have sufficient freeboard. No violations at this time.
1097261768 2011-05-13 UrbanProduction Wells No Violations The inspection was for preliminary restoration. There are some bare areas that need repaired and reseeded and the required identification was missing. I contacted Tim Levengood and requested that these issues be corrected immediately.
1110655664 2010-08-24 Urban Drill / Deepen / Reopen No Violations The required security fencing is installed and the well is being pumped up. No violations at this time.
1116802606 2018-05-01 UrbanProduction Wells No Violations Access was gained on a asphalt and gravel driveway. The well was operated as a electric pumping well. The wellhead was surrounded with a chain link fence. The fence was locked. The well was not operating during this inspection. All valves were in the open position. A domestic manifold and meter was connected to the 4.5 casing. The tank battery was surrounded with an earthen dike and locked chain link fence. The required I D signage was posted and legible. The tank battery consisted of one (1) 210 barrel stock tank, one (1) 100 barrel brine tank, one (1) 2408 horizontal separator and one (1) meter station. Proper spacing between equipment was observed. The load lines were plugged and locked. No leaks were found. No violations.
1341664078 2010-07-15 Drill / Deepen / Reopen No Violations The drilling pits are still open but are fenced, lined and in good condition.
1702954155 2010-08-16 Urban Drill / Deepen / Reopen No Violations The drilling pits have been solidified and covered over. The affected area has been rough graded. The tank battery has been built and the required security fencing is being installed. No violations at this time.
1711214410 2010-08-03 Drill / Deepen / Reopen No Violations Service rig is running tubing and rods and will set a pumping unit before leaving. The pits are scheduled to be solidified and closed this week.
1780373710 2010-07-13 Drill / Deepen / Reopen No Violations I received a call from Tim Levengood reporting that the cement inside of the 4-1/2 casing covered the interval to be perforated. One of three things may have happened. 1) the cement engineer did not displace with the necessary volume of water. The calculated volume was approximately 62.5 bbl. The operator reported displacing cement with 65 bbl of water. 2) the latchdown plug did not set as designed. The operator reported setting the plug with 450 psi. 3) a hole or split in the 4-1/2 casing diverted some of the displacement volume. Levengood requested permission to use the drilling pit to circulate into while drilling out the cement inside of the 4-1/2. Permission was granted.
1781263288 2010-07-28 Drill / Deepen / Reopen No Violations Universal and Down Hole Drilling were on site to drill out the cement inside of the 4-1/2 casing. Approximately 100 of cement will need to be removed before the well can be perforated and completed.
2136102650 2011-11-16 UrbanPreliminary Restoration No Violations Preliminary Restoration is approved.
294142591 2010-8-12 0:00: DD No Violations
672637003 2010-7-30 0:00: DD No Violations
948314177 2011-1-25 0:00: UP No Violations

For data sources see[9]