If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-153-23118 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.94,"lon":-81.62,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: DOMINION EAST OHIO | |
Well Pad ID: | |
Farm/Lease Name: CORBIN | |
License Status: Storage Well | |
License Date: 2014-03-05 | |
Spud Date: 2011-03-07 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: | |
Well Total Depth: 4313.00 ft | |
Configuration: Directional | |
Latitude: 40.940000 | |
Longitude: -81.620000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-09-01 | Proposed Formations:CLINTON, Issued Date:9/1/2010, Expired Date:8/31/2012 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Change of Owner | 2014-02-20 | Operator changed from 8632, DOMINION FIELD SERVICES INC to 240, DOMINION EAST OHIO |
APP | 2014-03-05 | Proposed Formations:CLINTON, Issued Date:3/5/2014, Expired Date:3/4/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SO, Proposed Well Class: |
Construction Permit Expires | 2015-03-04 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-02-18 | 4078 | 4119 | 124 |
4078 | 4119 | 124 | |
4078 | 4119 | 124 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2011-03-30 | H2O | 15 | 54381 Gal | 29000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | DOMINION EAST OHIO | 1206.00 | 0.00 | 365 |
2012 | DOMINION FIELD SERVICES INC | 1213.00 | 0.00 | 366 |
2013 | DOMINION FIELD SERVICES INC | 316.00 | 0.00 | 142 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | DOMINION EAST OHIO | Brine | 0 | 365 |
2012 | DOMINION FIELD SERVICES INC | Brine | 0 | 366 |
2013 | DOMINION FIELD SERVICES INC | Brine | 0 | 142 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-137947182 | 2019-2-20 0:00: | SO | No Violations | 0.50 |
-1528614470 | 2017-1-26 0:00: | SO | No Violations | |
-1549897039 | 2011-3-8 0:00:0 | UD | No Violations | |
-2088895340 | 2020-6-25 0:00: | SO | No Violations | 0.50 |
-308513638 | 2011-3-16 0:00: | UD | No Violations | |
-319839008 | 2018-3-15 0:00: | SO | No Violations | 0.50 |
0039371452 | 2011-03-03 | Urban Drill / Deepen / Reopen | No Violations | Daily Excavating is on site to stone the lease road and location in anticipation of the drilling rig arriving on or about 3/7. The identification is posted at the lease entrance. |
0137947182 | 2019-02-20 | Storage Well | No Violations | My inspection found the well is equipped with a plunger-lift system. The diked tank battery consists of a steel tank, a plastic brine tank, a vertical separator and a meter. The well is legibly identified. The well and tank battery are fenced in, gated and locked. No compliance issues are cited at this time. |
0308513638 | 2011-03-16 | Urban Drill / Deepen / Reopen | No Violations | Wildcat is drilling ahead on fluid and maintaining the predetermined angle. The rig should reach TD with 36 hours. The pits are fenced, lined and in good condition. |
0319839008 | 2018-03-15 | Storage Well | No Violations | I did a status check inspection for this storage well. The well is equipped with a plunger-lift system. The diked tank battery consists of a steel tank, a plastic brine tank, a vertical separator and a meter. The well is legibly identified. The well and tank battery are fenced in, gated and locked. No compliance issues are cited at this time. |
0455513182 | 2011-09-21 | Preliminary Restoration | No Violations | Preliminary Restoration is approved. |
0500367746 | 2011-03-11 | Urban Drill / Deepen / Reopen | No Violations | Wildcat is drilling ahead at the top of the Big Lime. They should be in the Salina within 48 hours and will know at that time if there is communication with the PPG solution cavity. Three empty 300 bbl frac tanks are being delivered today as required. |
0637957457 | 2011-03-28 | Drill / Deepen / Reopen | No Violations | On site training new inspectors Perforation of casing. |
0765401968 | 2011-03-07 | Urban Drill / Deepen / Reopen | No Violations | Wildcat Drilling is moving on location and will spud the well later today. No violations at this time. |
1216402280 | 2011-04-12 | Urban Drill / Deepen / Reopen | No Violations | The repair to the leaking top collar on the production string has been completed. The excavated area has been backfilled. |
1254991845 | 2014-12-26 | UrbanProduction Wells | No Violations | I was on location to conduct a status check of this well. The well is of plunger lift construction. The tank battery consists of a 140 BBL production tank and a mechanical separator. The valves at the wellhead were open. The low pressure relief valve, spark arrestor and charcoal filter were installed on the 140 BBL production tank. The tank battery was diked. The fencing around the wellhead and tank battery is an 8 foot high chain link fence and topped with three strands of barbed wire. The man doors to the tank battery and well were locked. The well is properly identified with a clear, legibly marked well identification sign. The lease road is stable and drivable. No violations found. |
1302049676 | 2011-03-14 | Urban Drill / Deepen / Reopen | No Violations | Wildcat is drilling ahead on fluid. The pits are fenced, lined and in good condition. The rig should reach TD in the next 72 hours. |
1528614470 | 2017-01-26 | Storage Well | No Violations | At the time of this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were closed and locked. The well was fenced and locked. The tank battery still contained production equipment and consisted of one 100 BBL production tank, one 50 BBL poly brine tank, a mechanical separator. The valves on the separator were closed. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. Lease access was stable. No violations at this time. |
1549897039 | 2011-03-08 | Urban Drill / Deepen / Reopen | No Violations | Set and cemented conductor casing early this morning. Should be ready to set and cement surface casing later tonight or early tomorrow morning. |
1976177959 | 2011-04-05 | Urban Drill / Deepen / Reopen | No Violations | During the Universal frac job on 3/30, the 4-1/2 casing failed just below the top collar. The top joint was a pup which may or may not have been cut from the same pipe. The casing is 11.6# and was cemented back to surface on 3/17 with 65 bbl returns. According to Don Kreager representing East Ohio, the job was approximately 70% complete and Universal was blending and pumping sand. It appears that the failure occurred in the collar and/or pipe threads. After the failure, the well started flowing back and the returning frac sand started cutting the casing. The well was allowed to blow down until it could safely be diverted to a frac tank. Some water and sand was released onto the location and a retention area was built to contain any lost material. According to Kreager, approximately 700 bbl of surface runoff, stormwater and possible frac flowback were pumped into empty 300 bbl frac tanks for later disposal. On this date, Baker Atlas was on site to run cased hole logs to evaluate the 4-1/2 casing condition. Dominion plans to remove and replace the 4-1/2 pup joint either by backing off, if possible or cutting off if not. This activity will occur in the next several days. |
39371452 | 2011-3-3 0:00:0 | UD | No Violations | |
455513182 | 2011-9-21 0:00: | PL | No Violations | |
500367746 | 2011-3-11 0:00: | UD | No Violations | |
637957457 | 2011-3-28 0:00: | DD | No Violations | |
765401968 | 2011-3-7 0:00:0 | UD | No Violations |