{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.1,"lon":-81.49,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: CCWD UNIT | |
License Status: Producing | |
License Date: 2011-12-07 | |
Spud Date: 2012-01-16 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2012-01-22 | |
Well Total Depth: 4025.00 ft | |
Configuration: Vertical | |
Latitude: 41.100000 | |
Longitude: -81.490000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-12-07 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:12/7/2011, Expired Date:12/6/2013 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-01-22 | |
Construction Permit Expires | 2012-12-06 | |
Completion Report Received | 2013-05-16 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-05-17 | 3848 | 3916 | 100 |
3848 | 3916 | 100 | |
3848 | 3916 | 100 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-03-28 | H2O | 15 | 73678 Gal | 53300 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | BASS ENERGY CO INC | 11020.00 | 571.00 | 207 |
2013 | BASS ENERGY CO INC | 10670.00 | 648.00 | 365 |
2014 | BASS ENERGY CO INC | 7469.00 | 436.00 | 365 |
2015 | BASS ENERGY CO INC | 6657.00 | 331.00 | 365 |
2016 | BASS ENERGY CO INC | 5494.00 | 347.00 | 365 |
2017 | BASS ENERGY CO INC | 4744.00 | 342.00 | 365 |
2018 | BASS ENERGY CO INC | 4283.00 | 308.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | BASS ENERGY CO INC | Brine | 955 | 207 |
2013 | BASS ENERGY CO INC | Brine | 689 | 365 |
2014 | BASS ENERGY CO INC | Brine | 447 | 365 |
2015 | BASS ENERGY CO INC | Brine | 356 | 365 |
2016 | BASS ENERGY CO INC | Brine | 322 | 365 |
2017 | BASS ENERGY CO INC | Brine | 250 | 365 |
2018 | BASS ENERGY CO INC | Brine | 333 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1033022294 | 2012-1-9 0:00:0 | UD | No Violations | |
-1215709114 | 2012-3-26 0:00: | UD | No Violations | |
-505161678 | 2012-1-20 0:00: | UD | No Violations | |
-936273302 | 2012-1-31 0:00: | UD | No Violations | |
-9763827 | 2012-7-16 0:00: | PL | No Violations | |
0009763827 | 2012-07-16 | Preliminary Restoration | No Violations | Preliminary Restoration is approved. |
0505161678 | 2012-01-20 | Urban Drill / Deepen / Reopen | No Violations | Poulson is drilling ahead on fluid at 3040. The pits are lined and in good condition. Poulson switched from air to fluid at 3142 as required by permit. |
0936273302 | 2012-01-31 | Urban Drill / Deepen / Reopen | No Violations | The drilling pits have been solidified and covered over. No violations at this time. |
1033022294 | 2012-01-09 | Urban Drill / Deepen / Reopen | No Violations | Equipment to arrive later today to start building the location. Poulson Drilling is scheduled for early next week. |
1215709114 | 2012-03-26 | Urban Drill / Deepen / Reopen | No Violations | Bass Energy is filling four 500 bbl frac tanks from an Akron city fire hydrant. The perforating is scheduled for 3/27 and the frac for 3/28. No violations at this time. |
1326990754 | 2012-01-17 | Urban Drill / Deepen / Reopen | No Violations | The rig set and cemented 109 of 11-3/4 conductor casing was set and cemented yesterday. The job was not witnessed since the activity occurred on a holiday. According to the records left on site by the cement contractor (Universal) and interviews with Poulson employees, cement did not circulate to surface. Circulation was maintained during the job but cement did not reach surface. After displacing the plug, the ground surface started to fail around the well which made surface grouting impractical. Rig integrity was never in doubt. It appears that insufficient cement was mixed and displaced. Additional cement will be ordered for cementing surface casing. |
1333979450 | 2012-03-28 | Urban Drill / Deepen / Reopen | No Violations | Berry Well Service and Universal Well Service were on site to frac the well. The slickwater job included 70,000 gallons of water and sand. No violations at this time. |
1465190061 | 2012-01-27 | Urban Drill / Deepen / Reopen | No Violations | Circle C is on site to provide the solidification material and the equipment to start closing the drilling pits. Pander Trucking has been removing pit water either from a 300 bbl frac tank or directly from the pits. |
1951648123 | 2012-01-18 | Urban Drill / Deepen / Reopen | No Violations | Plug down on the surface casing cement job was at 22:36 on 1/17. On site this morning to witness the blowout preventer (BOP) test. The annular BOP test was successful. Poulson will resume drilling the main hole this morning. The pits are lined and in good condition. |
2066609041 | 2012-01-25 | Urban Drill / Deepen / Reopen | No Violations | Poulson Drilling has moved off location. The drilling pits are fenced, lined and in good condition and are being pumped down. No violations at this time. |