X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-20420

Well Details

Well ID: 34-155-20420
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Weathersfield Township
Operator Name: RMI TITANIUM COMPANY
Well Pad ID:
Farm/Lease Name: DICENSO DICENSO & MASSACCI
License Status: Producing
License Date: 1976-09-14
Spud Date: 1976-10-27
Spud Drilling Contractor:
Final Drill Date: 1976-10-31
Well Total Depth: 4737.00 ft
Configuration: Vertical
Latitude: 41.180000
Longitude: -80.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1976-09-14 2125 EASTERN PETROLEUM CO GeoDate 9/14/76
Original Spud 1976-10-27 R.I. 11-3-76
Completed 1976-10-31 R.I. 11-3-76
Reached Total Depth 1976-10-31 R.I. 11-3-76
Completion Report Received 1976-11-30 R.I. 11-3-76
Construction Permit Expires 1977-09-14 R.I. 11-3-76
CO 1996-10-03 213 LOMAK OPERATING CO GeoDate 9/14/76
Change of Owner 2000-06-28 Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC
Change of Owner 2000-07-06 Operator changed from 6674, GREAT LAKES ENERGY PTNSHP LLC to 6786, RMI TITANIUM COMPANY
Record Last Modified 2013-10-03 R.I. 11-3-76

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4530 4580 30
4530 4580 30
4530 4580 30

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 93000 Gal 69500 INITIAL SHUT IN PRESSURE AFTER FRAC.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 RMI COMPANY 25105.00 223.00 0
2000 RMI TITANIUM COMPANY 7771.00 0.00 365
2001 RMI TITANIUM COMPANY 5797.00 61.00 365
2002 RMI TITANIUM COMPANY 4915.00 0.00 365
2003 RMI TITANIUM COMPANY 4642.00 0.00 365
2004 RMI TITANIUM COMPANY 4904.00 0.00 365
2005 RMI TITANIUM COMPANY 5257.00 0.00 365
2006 RMI TITANIUM COMPANY 4577.00 0.00 365
2007 RMI TITANIUM COMPANY 4316.00 0.00 365
2008 RMI TITANIUM COMPANY 3765.00 0.00 365
2009 RMI TITANIUM COMPANY 3753.00 0.00 365
2010 RMI TITANIUM COMPANY 2883.00 0.00 365
2011 RMI TITANIUM COMPANY 4170.00 0.00 0
2012 RMI TITANIUM COMPANY 4349.00 0.00 366
2013 RMI TITANIUM COMPANY 4514.00 0.00 365
2014 RMI TITANIUM COMPANY 4757.00 0.00 365
2015 RMI TITANIUM COMPANY 3429.00 0.00 365
2016 RMI TITANIUM COMPANY 4406.00 0.00 365
2017 RMI TITANIUM COMPANY 4382.00 0.00 365
2018 RMI TITANIUM COMPANY 3843.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 RMI COMPANY Brine 0 0
2000 RMI TITANIUM COMPANY Brine 13 365
2001 RMI TITANIUM COMPANY Brine 0 365
2002 RMI TITANIUM COMPANY Brine 0 365
2003 RMI TITANIUM COMPANY Brine 0 365
2004 RMI TITANIUM COMPANY Brine 0 365
2005 RMI TITANIUM COMPANY Brine 0 365
2006 RMI TITANIUM COMPANY Brine 0 365
2007 RMI TITANIUM COMPANY Brine 10 365
2008 RMI TITANIUM COMPANY Brine 0 365
2009 RMI TITANIUM COMPANY Brine 0 365
2010 RMI TITANIUM COMPANY Brine 0 365
2011 RMI TITANIUM COMPANY Brine 0
2012 RMI TITANIUM COMPANY Brine 0 366
2013 RMI TITANIUM COMPANY Brine 0 365
2014 RMI TITANIUM COMPANY Brine 0 365
2015 RMI TITANIUM COMPANY Brine 0 365
2016 RMI TITANIUM COMPANY Brine 0 365
2017 RMI TITANIUM COMPANY Brine 0 365
2018 RMI TITANIUM COMPANY Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2047910638 2013-7-25 0:00: UP No Violations 1.50
-937103393 2013-2-13 0:00: UP No Violations 0.50
0937103393 2013-02-13 UrbanProduction Wells No Violations My inspection found the well equipped with a plunger lift unit. The tank battery contained one, 100 barrel production tank. It was surrounded by a weathered dike; however, it meets containment requirements. The heat treated separator had the correct spacing, contained a 7 day production chart, and locked. The lease road was in stable condition and shared with permit number 2-0483. The production records were up to date on our database. This well was placed into production prior to House Bill 278.
1375724789 2013-07-16 UrbanProduction Wells No Violations

-up. I told Eric to remove all impacted weeds, shrubs, and soil and dispose of the material to the proper landfill.

2047910638 2013-07-25 UrbanProduction Wells No Violations My inspection found the entire oil spill impacted soil and weeds have been removed. All of the oil impacted soil and gravel inside of the tank battery has been removed. The dike has been rebuilt. The production tank was in place. The entire lease road has been graded. New drainage ditches have been installed.

For data sources see[9]