If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-20796 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.41,"lon":-80.88,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Bristol Township | |
Operator Name: VANGUARD OIL & GAS LLC | |
Well Pad ID: | |
Farm/Lease Name: MORRISON ROBERT HYDE | |
License Status: Producing | |
License Date: 1981-06-30 | |
Spud Date: 1978-03-01 | |
Spud Drilling Contractor: | |
Final Drill Date: 1978-03-09 | |
Well Total Depth: 4110.00 ft | |
Configuration: Vertical | |
Latitude: 41.410000 | |
Longitude: -80.880000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1978-03-01 | |
Completed | 1978-03-09 | |
Reached Total Depth | 1978-03-09 | |
CO | 1981-06-30 | 271 TGX CORP GeoDate 6/30/81 |
Change of Owner | 1997-06-25 | Operator changed from 271, TGX CORP to 182, BELDEN & BLAKE CO |
Change of Owner | 2001-04-06 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 457, ALSID OIL & GAS |
Record Last Modified | 2016-07-14 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3861 | 3924 | 14 |
3861 | 3924 | 14 | |
3861 | 3924 | 14 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1600 Bbl | 70000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TGX CORP | 3502.00 | 689.00 | 0 |
1985 | TGX CORP | 2994.00 | 640.00 | 365 |
1986 | TGX CORP | 2211.00 | 548.00 | 365 |
1987 | TGX CORP | 1913.00 | 493.00 | 365 |
1988 | TGX CORP | 1122.00 | 479.00 | 365 |
1989 | TGX CORP | 1216.00 | 433.00 | 365 |
1990 | TGX CORP | 887.00 | 244.00 | 365 |
1991 | TGX CORP | 950.00 | 182.00 | 365 |
1992 | TGX CORP | 88.00 | 142.00 | 365 |
1993 | TGX CORP | 217.00 | 152.00 | 335 |
1997 | ALSID OIL & GAS | 0.00 | 80.00 | 200 |
1998 | ALSID OIL & GAS | 958.00 | 414.00 | 365 |
1999 | ALSID OIL & GAS | 731.00 | 408.00 | 365 |
2000 | VANGUARD OIL & GAS LLC | 961.00 | 450.00 | 365 |
2001 | VANGUARD OIL & GAS LLC | 961.00 | 367.00 | 365 |
2002 | VANGUARD OIL & GAS LLC | 1019.00 | 398.00 | 365 |
2003 | VANGUARD OIL & GAS LLC | 753.00 | 237.00 | 365 |
2005 | VANGUARD OIL & GAS LLC | 1178.00 | 362.00 | 365 |
2006 | VANGUARD OIL & GAS LLC | 1261.00 | 339.00 | 365 |
2007 | VANGUARD OIL & GAS LLC | 1107.00 | 219.00 | 365 |
2008 | VANGUARD OIL & GAS LLC | 786.00 | 219.00 | 365 |
2009 | VANGUARD OIL & GAS LLC | 331.00 | 207.00 | 365 |
2010 | VANGUARD OIL & GAS LLC | 905.00 | 262.00 | 365 |
2011 | VANGUARD OIL & GAS LLC | 584.00 | 145.00 | 0 |
2012 | VANGUARD OIL & GAS LLC | 1205.00 | 352.00 | 366 |
2013 | VANGUARD OIL & GAS LLC | 1001.00 | 224.00 | 365 |
2014 | VANGUARD OIL & GAS LLC | 756.00 | 200.00 | 365 |
2015 | VANGUARD OIL & GAS LLC | 203.00 | 34.00 | 365 |
2016 | VANGUARD OIL & GAS LLC | 621.00 | 227.00 | 365 |
2017 | VANGUARD OIL & GAS LLC | 349.00 | 0.00 | 365 |
2018 | VANGUARD OIL & GAS LLC | 60.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TGX CORP | Brine | 380 | 0 |
1985 | TGX CORP | Brine | 263 | 365 |
1986 | TGX CORP | Brine | 216 | 365 |
1987 | TGX CORP | Brine | 350 | 365 |
1988 | TGX CORP | Brine | 385 | 365 |
1989 | TGX CORP | Brine | 210 | 365 |
1990 | TGX CORP | Brine | 35 | 365 |
1991 | TGX CORP | Brine | 35 | 365 |
1992 | TGX CORP | Brine | 0 | 365 |
1993 | TGX CORP | Brine | 70 | 335 |
1997 | ALSID OIL & GAS | Brine | 0 | 200 |
1998 | ALSID OIL & GAS | Brine | 277 | 365 |
1999 | ALSID OIL & GAS | Brine | 738 | 365 |
2000 | VANGUARD OIL & GAS LLC | Brine | 233 | 365 |
2001 | VANGUARD OIL & GAS LLC | Brine | 308 | 365 |
2002 | VANGUARD OIL & GAS LLC | Brine | 294 | 365 |
2003 | VANGUARD OIL & GAS LLC | Brine | 153 | 365 |
2005 | VANGUARD OIL & GAS LLC | Brine | 173 | 365 |
2006 | VANGUARD OIL & GAS LLC | Brine | 164 | 365 |
2007 | VANGUARD OIL & GAS LLC | Brine | 24 | 365 |
2008 | VANGUARD OIL & GAS LLC | Brine | 0 | 365 |
2009 | VANGUARD OIL & GAS LLC | Brine | 350 | 365 |
2010 | VANGUARD OIL & GAS LLC | Brine | 0 | 365 |
2011 | VANGUARD OIL & GAS LLC | Brine | 0 | |
2012 | VANGUARD OIL & GAS LLC | Brine | 355 | 366 |
2013 | VANGUARD OIL & GAS LLC | Brine | 222 | 365 |
2014 | VANGUARD OIL & GAS LLC | Brine | 365 | |
2015 | VANGUARD OIL & GAS LLC | Brine | 0 | 365 |
2016 | VANGUARD OIL & GAS LLC | Brine | 124 | 365 |
2017 | VANGUARD OIL & GAS LLC | Brine | 0 | 365 |
2018 | VANGUARD OIL & GAS LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1566048346 | 2012-9-20 0:00: | PW | No Violations | 0.50 |
0548496667 | 2012-10-23 | Production Wells | No Violations | I conducted a follow-up inspection. My inspection found no identification posted at the tank battery or at the pumping unit. I called Russell Miller at 330-506-8152 to inquire about the status of the identification sign. I was told Vanguard Oil & Gas ordered 50 new identification signs. I will re-inspect by 11/05/2012. |
0801165965 | 2016-06-03 | Production Wells | No Violations
-0797. The access road is in stable condition. The equipment on the site consists of the following:
| |
1100907392 | 2013-03-21 | Production Wells | No Violations | My inspection found the proper identification sign posted on the production tank per my request. |
1566048346 | 2012-09-20 | Production Wells | No Violations | I conducted a production well inspection status check. My inspection found the well equipped with a pumping unit that was in good condition and located east of the tank battery. The tank battery contained two, 100 barrel oil storage tanks, one, 50 barrel brine storage tank, two separators, and no identification posted. This well shares a lease road and tank battery with permit number 2-0797. I was told by Vanguard that they were in the progress of installing new signs. I will conduct a follow-up inspection by 10/3/2012. |
548496667 | 2012-10-23 0:00 | PW | No Violations | 0.50 |
801165965 | 2016-6-3 0:00:0 | PW | No Violations | 0.40 |
For data sources see[9]